subsurface/qt-models/cylindermodel.cpp

635 lines
18 KiB
C++
Raw Normal View History

// SPDX-License-Identifier: GPL-2.0
#include "cylindermodel.h"
#include "tankinfomodel.h"
#include "models.h"
#include "core/qthelper.h"
#include "core/divelist.h" // for mark_divelist_changed()
#include "core/color.h"
#include "qt-models/diveplannermodel.h"
#include "core/gettextfromc.h"
#include "core/subsurface-qt/DiveListNotifier.h"
CylindersModel::CylindersModel(QObject *parent) :
CleanerTableModel(parent),
changed(false),
rows(0)
{
// enum {REMOVE, TYPE, SIZE, WORKINGPRESS, START, END, O2, HE, DEPTH, MOD, MND, USE};
setHeaderDataStrings(QStringList() << "" << tr("Type") << tr("Size") << tr("Work press.") << tr("Start press.") << tr("End press.") << tr("O₂%") << tr("He%")
<< tr("Deco switch at") <<tr("Bot. MOD") <<tr("MND") << tr("Use"));
connect(&diveListNotifier, &DiveListNotifier::cylindersReset, this, &CylindersModel::cylindersReset);
}
QVariant CylindersModel::headerData(int section, Qt::Orientation orientation, int role) const
{
if (role == Qt::DisplayRole && orientation == Qt::Horizontal && in_planner() && section == WORKINGPRESS)
return tr("Start press.");
else
return CleanerTableModel::headerData(section, orientation, role);
}
CylindersModel *CylindersModel::instance()
{
static CylindersModel self;
return &self;
}
static QString get_cylinder_string(cylinder_t *cyl)
{
QString unit;
int decimals;
unsigned int ml = cyl->type.size.mliter;
pressure_t wp = cyl->type.workingpressure;
double value;
// We cannot use "get_volume_units()", because even when
// using imperial units we may need to show the size in
// liters: if we don't have a working pressure, we cannot
// convert the cylinder size to cuft.
if (wp.mbar && prefs.units.volume == units::CUFT) {
value = ml_to_cuft(ml) * bar_to_atm(wp.mbar / 1000.0);
decimals = (value > 20.0) ? 0 : (value > 2.0) ? 1 : 2;
unit = CylindersModel::tr("cuft");
} else {
value = ml / 1000.0;
decimals = 1;
unit = CylindersModel::tr("");
}
return QString("%L1").arg(value, 0, 'f', decimals) + unit;
}
static QString gas_volume_string(int ml, const char *tail)
{
double vol;
const char *unit;
int decimals;
vol = get_volume_units(ml, NULL, &unit);
decimals = (vol > 20.0) ? 0 : (vol > 2.0) ? 1 : 2;
return QString("%L1 %2 %3").arg(vol, 0, 'f', decimals).arg(unit).arg(tail);
}
Tweak cylinder equipment tooltips While playing around with the current subsurface, I realized that while we give the gas volume and Z factor for the beginning/end pressures in the newly added tooltips, there is no way to actually see that same information for the working pressure. So if you have filled in cylinder type information, but don't have any actual gas usage information, there will be no cylinder tooltips at all. But you might still want to know what the actual volume for a particular cylinder is, and what the Z value for that working pressure is. So this tweaks the tool-tips a bit. When mousing over the pressure fields (ie "working pressure", "start" and "end"), it now always gives the cylinder gas volume and Z factor for that pressure, so for example on an AL72 that has a working pressure of 3000 psi and that contains air the tooltip will say: 69 cuft, Z=1.040 when you mouse over the working pressure field (that's obviously with imperial units, in metric you'll see liters of gas). When mousing over the type/size field, it gives the used gas amounts, ie something like this: 37 cuft (82 cuft -> 45 cuft) but if the cylinder doesn't have starting/ending pressures (and thus no used gas information), this patch will make subsurface show the working pressure data instead, so that you at least get something. This all seems more useful than what my first version gave. NOTE! This makes commit adaeb506b7a1 ("Show both the nominal and "real" size for an imperial cylinder") kind of pointless. You now see the real size in the tooltip when you mouse over the size, and now it actually works both for imperial and metric people, so the tooltip is in many ways the better model. Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-01-16 00:07:35 +00:00
static QVariant gas_wp_tooltip(cylinder_t *cyl);
static QVariant gas_usage_tooltip(cylinder_t *cyl)
{
pressure_t startp = cyl->start.mbar ? cyl->start : cyl->sample_start;
pressure_t endp = cyl->end.mbar ? cyl->end : cyl->sample_end;
int start, end, used;
start = gas_volume(cyl, startp);
end = gas_volume(cyl, endp);
used = (end && start > end) ? start - end : 0;
if (!used)
Tweak cylinder equipment tooltips While playing around with the current subsurface, I realized that while we give the gas volume and Z factor for the beginning/end pressures in the newly added tooltips, there is no way to actually see that same information for the working pressure. So if you have filled in cylinder type information, but don't have any actual gas usage information, there will be no cylinder tooltips at all. But you might still want to know what the actual volume for a particular cylinder is, and what the Z value for that working pressure is. So this tweaks the tool-tips a bit. When mousing over the pressure fields (ie "working pressure", "start" and "end"), it now always gives the cylinder gas volume and Z factor for that pressure, so for example on an AL72 that has a working pressure of 3000 psi and that contains air the tooltip will say: 69 cuft, Z=1.040 when you mouse over the working pressure field (that's obviously with imperial units, in metric you'll see liters of gas). When mousing over the type/size field, it gives the used gas amounts, ie something like this: 37 cuft (82 cuft -> 45 cuft) but if the cylinder doesn't have starting/ending pressures (and thus no used gas information), this patch will make subsurface show the working pressure data instead, so that you at least get something. This all seems more useful than what my first version gave. NOTE! This makes commit adaeb506b7a1 ("Show both the nominal and "real" size for an imperial cylinder") kind of pointless. You now see the real size in the tooltip when you mouse over the size, and now it actually works both for imperial and metric people, so the tooltip is in many ways the better model. Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-01-16 00:07:35 +00:00
return gas_wp_tooltip(cyl);
return gas_volume_string(used, "(") +
gas_volume_string(start, " -> ") +
gas_volume_string(end, ")");
}
static QVariant gas_volume_tooltip(cylinder_t *cyl, pressure_t p)
{
int vol = gas_volume(cyl, p);
double Z;
if (!vol)
return QVariant();
Z = gas_compressibility_factor(cyl->gasmix, p.mbar / 1000.0);
return gas_volume_string(vol, "(Z=") + QString("%1)").arg(Z, 0, 'f', 3);
}
Tweak cylinder equipment tooltips While playing around with the current subsurface, I realized that while we give the gas volume and Z factor for the beginning/end pressures in the newly added tooltips, there is no way to actually see that same information for the working pressure. So if you have filled in cylinder type information, but don't have any actual gas usage information, there will be no cylinder tooltips at all. But you might still want to know what the actual volume for a particular cylinder is, and what the Z value for that working pressure is. So this tweaks the tool-tips a bit. When mousing over the pressure fields (ie "working pressure", "start" and "end"), it now always gives the cylinder gas volume and Z factor for that pressure, so for example on an AL72 that has a working pressure of 3000 psi and that contains air the tooltip will say: 69 cuft, Z=1.040 when you mouse over the working pressure field (that's obviously with imperial units, in metric you'll see liters of gas). When mousing over the type/size field, it gives the used gas amounts, ie something like this: 37 cuft (82 cuft -> 45 cuft) but if the cylinder doesn't have starting/ending pressures (and thus no used gas information), this patch will make subsurface show the working pressure data instead, so that you at least get something. This all seems more useful than what my first version gave. NOTE! This makes commit adaeb506b7a1 ("Show both the nominal and "real" size for an imperial cylinder") kind of pointless. You now see the real size in the tooltip when you mouse over the size, and now it actually works both for imperial and metric people, so the tooltip is in many ways the better model. Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-01-16 00:07:35 +00:00
static QVariant gas_wp_tooltip(cylinder_t *cyl)
{
return gas_volume_tooltip(cyl, cyl->type.workingpressure);
}
static QVariant gas_start_tooltip(cylinder_t *cyl)
{
return gas_volume_tooltip(cyl, cyl->start.mbar ? cyl->start : cyl->sample_start);
}
static QVariant gas_end_tooltip(cylinder_t *cyl)
{
return gas_volume_tooltip(cyl, cyl->end.mbar ? cyl->end : cyl->sample_end);
}
static QVariant percent_string(fraction_t fraction)
{
int permille = fraction.permille;
if (!permille)
return QVariant();
return QString("%L1%").arg(permille / 10.0, 0, 'f', 1);
}
QVariant CylindersModel::data(const QModelIndex &index, int role) const
{
if (!index.isValid() || index.row() >= MAX_CYLINDERS)
return QVariant();
cylinder_t *cyl = &displayed_dive.cylinder[index.row()];
switch (role) {
case Qt::BackgroundRole: {
switch (index.column()) {
// mark the cylinder start / end pressure in red if the values
// seem implausible
case START:
case END:
pressure_t startp, endp;
startp = cyl->start.mbar ? cyl->start : cyl->sample_start;
endp = cyl->end.mbar ? cyl->end : cyl->sample_end;
if ((startp.mbar && !endp.mbar) ||
(endp.mbar && startp.mbar <= endp.mbar))
return REDORANGE1_HIGH_TRANS;
break;
}
break;
}
case Qt::FontRole: {
QFont font = defaultModelFont();
switch (index.column()) {
// if we don't have manually set pressure data use italic font
case START:
font.setItalic(!cyl->start.mbar);
break;
case END:
font.setItalic(!cyl->end.mbar);
break;
}
return font;
}
case Qt::TextAlignmentRole:
return Qt::AlignCenter;
case Qt::DisplayRole:
case Qt::EditRole:
switch (index.column()) {
case TYPE:
return QString(cyl->type.description);
case SIZE:
if (cyl->type.size.mliter)
return get_cylinder_string(cyl);
break;
case WORKINGPRESS:
if (cyl->type.workingpressure.mbar)
return get_pressure_string(cyl->type.workingpressure, true);
break;
case START:
if (cyl->start.mbar)
return get_pressure_string(cyl->start, true);
else if (cyl->sample_start.mbar)
return get_pressure_string(cyl->sample_start, true);
break;
case END:
if (cyl->end.mbar)
return get_pressure_string(cyl->end, true);
else if (cyl->sample_end.mbar)
return get_pressure_string(cyl->sample_end, true);
break;
case O2:
return percent_string(cyl->gasmix.o2);
case HE:
return percent_string(cyl->gasmix.he);
case DEPTH:
return get_depth_string(cyl->depth, true);
case MOD:
if (cyl->bestmix_o2) {
return QStringLiteral("*");
} else {
pressure_t modpO2;
modpO2.mbar = prefs.bottompo2;
return get_depth_string(gas_mod(cyl->gasmix, modpO2, &displayed_dive, M_OR_FT(1,1)), true);
}
case MND:
if (cyl->bestmix_he)
return QStringLiteral("*");
else
return get_depth_string(gas_mnd(cyl->gasmix, prefs.bestmixend, &displayed_dive, M_OR_FT(1,1)), true);
break;
case USE:
return gettextFromC::tr(cylinderuse_text[cyl->cylinder_use]);
}
break;
case Qt::DecorationRole:
case Qt::SizeHintRole:
if (index.column() == REMOVE) {
if ((in_planner() && DivePlannerPointsModel::instance()->tankInUse(index.row())) ||
(!in_planner() && is_cylinder_prot(&displayed_dive, index.row()))) {
return trashForbiddenIcon();
}
return trashIcon();
}
break;
case Qt::ToolTipRole:
switch (index.column()) {
case REMOVE:
if ((in_planner() && DivePlannerPointsModel::instance()->tankInUse(index.row())) ||
(!in_planner() && is_cylinder_prot(&displayed_dive, index.row()))) {
return tr("This gas is in use. Only cylinders that are not used in the dive can be removed.");
}
return tr("Clicking here will remove this cylinder.");
Tweak cylinder equipment tooltips While playing around with the current subsurface, I realized that while we give the gas volume and Z factor for the beginning/end pressures in the newly added tooltips, there is no way to actually see that same information for the working pressure. So if you have filled in cylinder type information, but don't have any actual gas usage information, there will be no cylinder tooltips at all. But you might still want to know what the actual volume for a particular cylinder is, and what the Z value for that working pressure is. So this tweaks the tool-tips a bit. When mousing over the pressure fields (ie "working pressure", "start" and "end"), it now always gives the cylinder gas volume and Z factor for that pressure, so for example on an AL72 that has a working pressure of 3000 psi and that contains air the tooltip will say: 69 cuft, Z=1.040 when you mouse over the working pressure field (that's obviously with imperial units, in metric you'll see liters of gas). When mousing over the type/size field, it gives the used gas amounts, ie something like this: 37 cuft (82 cuft -> 45 cuft) but if the cylinder doesn't have starting/ending pressures (and thus no used gas information), this patch will make subsurface show the working pressure data instead, so that you at least get something. This all seems more useful than what my first version gave. NOTE! This makes commit adaeb506b7a1 ("Show both the nominal and "real" size for an imperial cylinder") kind of pointless. You now see the real size in the tooltip when you mouse over the size, and now it actually works both for imperial and metric people, so the tooltip is in many ways the better model. Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-01-16 00:07:35 +00:00
case TYPE:
case SIZE:
return gas_usage_tooltip(cyl);
Tweak cylinder equipment tooltips While playing around with the current subsurface, I realized that while we give the gas volume and Z factor for the beginning/end pressures in the newly added tooltips, there is no way to actually see that same information for the working pressure. So if you have filled in cylinder type information, but don't have any actual gas usage information, there will be no cylinder tooltips at all. But you might still want to know what the actual volume for a particular cylinder is, and what the Z value for that working pressure is. So this tweaks the tool-tips a bit. When mousing over the pressure fields (ie "working pressure", "start" and "end"), it now always gives the cylinder gas volume and Z factor for that pressure, so for example on an AL72 that has a working pressure of 3000 psi and that contains air the tooltip will say: 69 cuft, Z=1.040 when you mouse over the working pressure field (that's obviously with imperial units, in metric you'll see liters of gas). When mousing over the type/size field, it gives the used gas amounts, ie something like this: 37 cuft (82 cuft -> 45 cuft) but if the cylinder doesn't have starting/ending pressures (and thus no used gas information), this patch will make subsurface show the working pressure data instead, so that you at least get something. This all seems more useful than what my first version gave. NOTE! This makes commit adaeb506b7a1 ("Show both the nominal and "real" size for an imperial cylinder") kind of pointless. You now see the real size in the tooltip when you mouse over the size, and now it actually works both for imperial and metric people, so the tooltip is in many ways the better model. Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-01-16 00:07:35 +00:00
case WORKINGPRESS:
return gas_wp_tooltip(cyl);
case START:
return gas_start_tooltip(cyl);
case END:
return gas_end_tooltip(cyl);
case DEPTH:
return tr("Switch depth for deco gas. Calculated using Deco pO₂ preference, unless set manually.");
case MOD:
return tr("Calculated using Bottom pO₂ preference. Setting MOD adjusts O₂%, set to '*' for best O₂% for max. depth.");
case MND:
return tr("Calculated using Best Mix END preference. Setting MND adjusts He%, set to '*' for best He% for max. depth.");
}
break;
}
return QVariant();
}
cylinder_t *CylindersModel::cylinderAt(const QModelIndex &index)
{
return &displayed_dive.cylinder[index.row()];
}
// this is our magic 'pass data in' function that allows the delegate to get
// the data here without silly unit conversions;
// so we only implement the two columns we care about
void CylindersModel::passInData(const QModelIndex &index, const QVariant &value)
{
cylinder_t *cyl = cylinderAt(index);
switch (index.column()) {
case SIZE:
if (cyl->type.size.mliter != value.toInt()) {
cyl->type.size.mliter = value.toInt();
dataChanged(index, index);
}
break;
case WORKINGPRESS:
if (cyl->type.workingpressure.mbar != value.toInt()) {
cyl->type.workingpressure.mbar = value.toInt();
dataChanged(index, index);
}
break;
}
}
bool CylindersModel::setData(const QModelIndex &index, const QVariant &value, int role)
{
QString vString;
cylinder_t *cyl = cylinderAt(index);
switch (index.column()) {
case TYPE:
if (!value.isNull()) {
QByteArray ba = value.toByteArray();
const char *text = ba.constData();
if (!cyl->type.description || strcmp(cyl->type.description, text)) {
cyl->type.description = strdup(text);
changed = true;
}
}
break;
case SIZE:
if (CHANGED()) {
TankInfoModel *tanks = TankInfoModel::instance();
QModelIndexList matches = tanks->match(tanks->index(0, 0), Qt::DisplayRole, cyl->type.description);
cyl->type.size = string_to_volume(qPrintable(vString), cyl->type.workingpressure);
mark_divelist_changed(true);
if (!matches.isEmpty())
tanks->setData(tanks->index(matches.first().row(), TankInfoModel::ML), cyl->type.size.mliter);
changed = true;
}
break;
case WORKINGPRESS:
if (CHANGED()) {
TankInfoModel *tanks = TankInfoModel::instance();
QModelIndexList matches = tanks->match(tanks->index(0, 0), Qt::DisplayRole, cyl->type.description);
cyl->type.workingpressure = string_to_pressure(qPrintable(vString));
if (!matches.isEmpty())
tanks->setData(tanks->index(matches.first().row(), TankInfoModel::BAR), cyl->type.workingpressure.mbar / 1000.0);
changed = true;
}
break;
case START:
if (CHANGED()) {
cyl->start = string_to_pressure(qPrintable(vString));
changed = true;
}
break;
case END:
if (CHANGED()) {
//&& (!cyl->start.mbar || string_to_pressure(qPrintable(vString)).mbar <= cyl->start.mbar)) {
cyl->end = string_to_pressure(qPrintable(vString));
changed = true;
}
break;
case O2:
if (CHANGED()) {
cyl->gasmix.o2 = string_to_fraction(qPrintable(vString));
// fO2 + fHe must not be greater than 1
if (get_o2(cyl->gasmix) + get_he(cyl->gasmix) > 1000)
cyl->gasmix.he.permille = 1000 - get_o2(cyl->gasmix);
pressure_t modpO2;
if (displayed_dive.dc.divemode == PSCR)
modpO2.mbar = prefs.decopo2 + (1000 - get_o2(cyl->gasmix)) * SURFACE_PRESSURE *
prefs.o2consumption / prefs.decosac / prefs.pscr_ratio;
else
modpO2.mbar = prefs.decopo2;
cyl->depth = gas_mod(cyl->gasmix, modpO2, &displayed_dive, M_OR_FT(3, 10));
cyl->bestmix_o2 = false;
changed = true;
}
break;
case HE:
if (CHANGED()) {
cyl->gasmix.he = string_to_fraction(qPrintable(vString));
// fO2 + fHe must not be greater than 1
if (get_o2(cyl->gasmix) + get_he(cyl->gasmix) > 1000)
cyl->gasmix.o2.permille = 1000 - get_he(cyl->gasmix);
cyl->bestmix_he = false;
changed = true;
}
break;
case DEPTH:
if (CHANGED()) {
cyl->depth = string_to_depth(qPrintable(vString));
changed = true;
}
break;
case MOD:
if (CHANGED()) {
if (QString::compare(qPrintable(vString), "*") == 0) {
cyl->bestmix_o2 = true;
2017-03-06 12:27:39 +00:00
// Calculate fO2 for max. depth
cyl->gasmix.o2 = best_o2(displayed_dive.maxdepth, &displayed_dive);
} else {
cyl->bestmix_o2 = false;
// Calculate fO2 for input depth
cyl->gasmix.o2 = best_o2(string_to_depth(qPrintable(vString)), &displayed_dive);
}
pressure_t modpO2;
modpO2.mbar = prefs.decopo2;
cyl->depth = gas_mod(cyl->gasmix, modpO2, &displayed_dive, M_OR_FT(3, 10));
changed = true;
}
break;
case MND:
if (CHANGED()) {
if (QString::compare(qPrintable(vString), "*") == 0) {
cyl->bestmix_he = true;
2017-03-06 12:27:39 +00:00
// Calculate fO2 for max. depth
cyl->gasmix.he = best_he(displayed_dive.maxdepth, &displayed_dive, prefs.o2narcotic, cyl->gasmix.o2);
} else {
cyl->bestmix_he = false;
// Calculate fHe for input depth
cyl->gasmix.he = best_he(string_to_depth(qPrintable(vString)), &displayed_dive, prefs.o2narcotic, cyl->gasmix.o2);
}
changed = true;
}
break;
case USE:
if (CHANGED()) {
int use = vString.toInt();
if (use > NUM_GAS_USE - 1 || use < 0)
use = 0;
cyl->cylinder_use = (enum cylinderuse)use;
changed = true;
}
break;
}
dataChanged(index, index);
return true;
}
int CylindersModel::rowCount(const QModelIndex&) const
{
return rows;
}
void CylindersModel::add()
{
if (rows >= MAX_CYLINDERS) {
return;
}
int row = rows;
fill_default_cylinder(&displayed_dive, row);
displayed_dive.cylinder[row].start = displayed_dive.cylinder[row].type.workingpressure;
displayed_dive.cylinder[row].manually_added = true;
displayed_dive.cylinder[row].cylinder_use = OC_GAS;
beginInsertRows(QModelIndex(), row, row);
rows++;
changed = true;
endInsertRows();
emit dataChanged(createIndex(row, 0), createIndex(row, COLUMNS - 1));
}
void CylindersModel::clear()
{
if (rows > 0) {
beginRemoveRows(QModelIndex(), 0, rows - 1);
endRemoveRows();
}
}
Tweak the "display_unused_tanks" preferences logic This is really unrelated to my recent "multiple gas pressures" work, but the test case from Gaetan Bisson showed that the logic for which cylinders to show in the equipment tab was less than optimal. We basically used to show only cylinders that were actively used, unless you had the "display_unused_tanks" preference option set. That comes from some dive computers reporting a *lot* of cylinders that the diver really doesn't even have with him on the dive. And showing those extra dummy cylinders gets pretty annoying after a time, which is why we default to not showing unused tanks. However, in Gaetan's case, he had a total of four cylinders on the dive: the O2 and diluent bottle for the rebreather dive, and then bailout bottles (both air and deco). And while the bailout bottles weren't actually used, Gaetan had actually filled in all the pressure details etc for them, and so you'd really expect them to show up. These were *not* just some extraneous default cylinder filled in by an over-eager dive computer. But because the bailout wasn't used, the manual pressures at the end were the same as at the beginning, and the "unused cylinder" logic triggered anyway. So tweak the logic a bit, and say that you show cylinder equipment not only if it has been used on the dive, but also if it has any pressure information for it. So the o nly cylinders we don't show are the ones that really have no interesting information at all, except for possibly the cylinder tank type itself (which is exactly what the over-eager dive computer case might fill in, usually in the form of a default cylinder type). Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-31 04:09:24 +00:00
static bool show_cylinder(struct dive *dive, int i)
{
cylinder_t *cyl = dive->cylinder + i;
if (is_cylinder_used(dive, i))
return true;
if (cylinder_none(cyl))
return false;
if (cyl->start.mbar || cyl->sample_start.mbar ||
cyl->end.mbar || cyl->sample_end.mbar)
return true;
if (cyl->manually_added)
return true;
/*
* The cylinder has some data, but none of it is very interesting,
* it has no pressures and no gas switches. Do we want to show it?
*/
return prefs.display_unused_tanks;
}
void CylindersModel::updateDive()
{
clear();
rows = 0;
#ifdef DEBUG_CYL
dump_cylinders(&displayed_dive, true);
#endif
for (int i = 0; i < MAX_CYLINDERS; i++) {
Tweak the "display_unused_tanks" preferences logic This is really unrelated to my recent "multiple gas pressures" work, but the test case from Gaetan Bisson showed that the logic for which cylinders to show in the equipment tab was less than optimal. We basically used to show only cylinders that were actively used, unless you had the "display_unused_tanks" preference option set. That comes from some dive computers reporting a *lot* of cylinders that the diver really doesn't even have with him on the dive. And showing those extra dummy cylinders gets pretty annoying after a time, which is why we default to not showing unused tanks. However, in Gaetan's case, he had a total of four cylinders on the dive: the O2 and diluent bottle for the rebreather dive, and then bailout bottles (both air and deco). And while the bailout bottles weren't actually used, Gaetan had actually filled in all the pressure details etc for them, and so you'd really expect them to show up. These were *not* just some extraneous default cylinder filled in by an over-eager dive computer. But because the bailout wasn't used, the manual pressures at the end were the same as at the beginning, and the "unused cylinder" logic triggered anyway. So tweak the logic a bit, and say that you show cylinder equipment not only if it has been used on the dive, but also if it has any pressure information for it. So the o nly cylinders we don't show are the ones that really have no interesting information at all, except for possibly the cylinder tank type itself (which is exactly what the over-eager dive computer case might fill in, usually in the form of a default cylinder type). Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-31 04:09:24 +00:00
if (show_cylinder(&displayed_dive, i))
rows = i + 1;
}
if (rows > 0) {
beginInsertRows(QModelIndex(), 0, rows - 1);
endInsertRows();
}
}
void CylindersModel::copyFromDive(dive *d)
{
if (!d)
return;
rows = 0;
for (int i = 0; i < MAX_CYLINDERS; i++) {
Tweak the "display_unused_tanks" preferences logic This is really unrelated to my recent "multiple gas pressures" work, but the test case from Gaetan Bisson showed that the logic for which cylinders to show in the equipment tab was less than optimal. We basically used to show only cylinders that were actively used, unless you had the "display_unused_tanks" preference option set. That comes from some dive computers reporting a *lot* of cylinders that the diver really doesn't even have with him on the dive. And showing those extra dummy cylinders gets pretty annoying after a time, which is why we default to not showing unused tanks. However, in Gaetan's case, he had a total of four cylinders on the dive: the O2 and diluent bottle for the rebreather dive, and then bailout bottles (both air and deco). And while the bailout bottles weren't actually used, Gaetan had actually filled in all the pressure details etc for them, and so you'd really expect them to show up. These were *not* just some extraneous default cylinder filled in by an over-eager dive computer. But because the bailout wasn't used, the manual pressures at the end were the same as at the beginning, and the "unused cylinder" logic triggered anyway. So tweak the logic a bit, and say that you show cylinder equipment not only if it has been used on the dive, but also if it has any pressure information for it. So the o nly cylinders we don't show are the ones that really have no interesting information at all, except for possibly the cylinder tank type itself (which is exactly what the over-eager dive computer case might fill in, usually in the form of a default cylinder type). Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-31 04:09:24 +00:00
if (show_cylinder(d, i))
rows = i + 1;
}
if (rows > 0) {
beginInsertRows(QModelIndex(), 0, rows - 1);
endInsertRows();
}
}
Qt::ItemFlags CylindersModel::flags(const QModelIndex &index) const
{
if (index.column() == REMOVE || index.column() == USE)
return Qt::ItemIsEnabled;
return QAbstractItemModel::flags(index) | Qt::ItemIsEditable;
}
void CylindersModel::remove(const QModelIndex &index)
{
std::vector<int> mapping(MAX_CYLINDERS);
if (index.column() == USE) {
cylinder_t *cyl = cylinderAt(index);
if (cyl->cylinder_use == OC_GAS)
cyl->cylinder_use = NOT_USED;
else if (cyl->cylinder_use == NOT_USED)
cyl->cylinder_use = OC_GAS;
changed = true;
dataChanged(index, index);
return;
}
if (index.column() != REMOVE) {
return;
}
if ((in_planner() && DivePlannerPointsModel::instance()->tankInUse(index.row())) ||
(!in_planner() && is_cylinder_prot(&displayed_dive, index.row())))
return;
beginRemoveRows(QModelIndex(), index.row(), index.row()); // yah, know, ugly.
rows--;
remove_cylinder(&displayed_dive, index.row());
for (int i = 0; i < index.row(); i++)
mapping[i] = i;
// No mapping for removed gas, set to -1
mapping[index.row()] = -1;
for (int i = index.row() + 1; i < MAX_CYLINDERS; i++)
mapping[i] = i - 1;
cylinder_renumber(&displayed_dive, &mapping[0]);
if (in_planner())
DivePlannerPointsModel::instance()->cylinderRenumber(&mapping[0]);
changed = true;
endRemoveRows();
dataChanged(index, index);
}
void CylindersModel::moveAtFirst(int cylid)
{
std::vector<int> mapping(MAX_CYLINDERS);
cylinder_t temp_cyl;
beginMoveRows(QModelIndex(), cylid, cylid, QModelIndex(), 0);
memmove(&temp_cyl, &displayed_dive.cylinder[cylid], sizeof(temp_cyl));
for (int i = cylid - 1; i >= 0; i--) {
memmove(&displayed_dive.cylinder[i + 1], &displayed_dive.cylinder[i], sizeof(temp_cyl));
mapping[i] = i + 1;
}
memmove(&displayed_dive.cylinder[0], &temp_cyl, sizeof(temp_cyl));
mapping[cylid] = 0;
for (int i = cylid + 1; i < MAX_CYLINDERS; i++)
mapping[i] = i;
cylinder_renumber(&displayed_dive, &mapping[0]);
if (in_planner())
DivePlannerPointsModel::instance()->cylinderRenumber(&mapping[0]);
changed = true;
endMoveRows();
}
void CylindersModel::updateDecoDepths(pressure_t olddecopo2)
{
pressure_t decopo2;
decopo2.mbar = prefs.decopo2;
for (int i = 0; i < MAX_CYLINDERS; i++) {
cylinder_t *cyl = &displayed_dive.cylinder[i];
/* If the gas's deco MOD matches the old pO2, it will have been automatically calculated and should be updated.
* If they don't match, we should leave the user entered depth as it is */
if (cyl->depth.mm == gas_mod(cyl->gasmix, olddecopo2, &displayed_dive, M_OR_FT(3, 10)).mm) {
cyl->depth = gas_mod(cyl->gasmix, decopo2, &displayed_dive, M_OR_FT(3, 10));
}
}
emit dataChanged(createIndex(0, 0), createIndex(MAX_CYLINDERS - 1, COLUMNS - 1));
}
void CylindersModel::updateTrashIcon()
{
emit dataChanged(createIndex(0, 0), createIndex(MAX_CYLINDERS - 1, 0));
}
bool CylindersModel::updateBestMixes()
{
// Check if any of the cylinders are best mixes, update if needed
bool gasUpdated = false;
for (int i = 0; i < MAX_CYLINDERS; i++) {
cylinder_t *cyl = &displayed_dive.cylinder[i];
if (cyl->bestmix_o2) {
cyl->gasmix.o2 = best_o2(displayed_dive.maxdepth, &displayed_dive);
// fO2 + fHe must not be greater than 1
if (get_o2(cyl->gasmix) + get_he(cyl->gasmix) > 1000)
cyl->gasmix.he.permille = 1000 - get_o2(cyl->gasmix);
pressure_t modpO2;
modpO2.mbar = prefs.decopo2;
cyl->depth = gas_mod(cyl->gasmix, modpO2, &displayed_dive, M_OR_FT(3, 10));
gasUpdated = true;
}
if (cyl->bestmix_he) {
cyl->gasmix.he = best_he(displayed_dive.maxdepth, &displayed_dive, prefs.o2narcotic, cyl->gasmix.o2);
// fO2 + fHe must not be greater than 1
if (get_o2(cyl->gasmix) + get_he(cyl->gasmix) > 1000)
cyl->gasmix.o2.permille = 1000 - get_he(cyl->gasmix);
gasUpdated = true;
}
}
/* This slot is called when the bottom pO2 and END preferences are updated, we want to
* emit dataChanged so MOD and MND are refreshed, even if the gas mix hasn't been changed */
if (gasUpdated)
emit dataChanged(createIndex(0, 0), createIndex(MAX_CYLINDERS - 1, COLUMNS - 1));
return gasUpdated;
}
void CylindersModel::cylindersReset(const QVector<dive *> &dives)
{
// This model only concerns the currently displayed dive. If this is not among the
// dives that had their cylinders reset, exit.
if (!current_dive || std::find(dives.begin(), dives.end(), current_dive) == dives.end())
return;
// Copy the cylinders from the current dive to the displayed dive.
copy_cylinders(current_dive, &displayed_dive, false);
// And update the model..
updateDive();
}