Use boyle_compensation in profile

otherwise VPM-B planned profiles seem to violate the ceiling. This needs
the first_stop_pressure to be available also in the profile, so I made
it global in planner.c

Important lesson: If you want to use deco_allowed_depth on a tissue_tolerance
that comes from a VPM-B planned dive, you have to call boyles_law() before
add_segment()!

Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
Robert C. Helling 2015-08-19 23:14:00 +02:00 committed by Dirk Hohndel
parent 2a50731139
commit 0bb65a17cb
4 changed files with 17 additions and 9 deletions

View file

@ -853,6 +853,7 @@ void calculate_deco_information(struct dive *dive, struct divecomputer *dc, stru
time_stepsize = t1 - t0;
for (j = t0 + time_stepsize; j <= t1; j += time_stepsize) {
int depth = interpolate(entry[-1].depth, entry[0].depth, j - t0, t1 - t0);
boyles_law(depth_to_mbar(entry->depth, &displayed_dive) / 1000.0);
double min_pressure = add_segment(depth_to_mbar(depth, dive) / 1000.0,
&dive->cylinder[entry->cylinderindex].gasmix, time_stepsize, entry->o2pressure.mbar, dive, entry->sac);
tissue_tolerance = min_pressure;