For CCR dives, the diluent cylinder is the current cylinder

Change the meaning that _the_ cylinder (as we treat it in OC dives) is the
diluent cylinder (rather than the O2 cylinder). This eliminates special
cases. Now, for CCR, we have to handle the O2 cylinder in addition
(rather than the diluent in addition).

Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
Robert C. Helling 2014-11-17 12:25:00 +01:00 committed by Dirk Hohndel
parent 5ed4876ad2
commit 0d7c192e6e
9 changed files with 1772 additions and 1773 deletions

2
dive.h
View file

@ -184,7 +184,7 @@ struct sample // BASE TYPE BYTES UNITS RANGE DE
depth_t stopdepth; // int32_t 4 mm (0-2000 km) depth of next deco stop
temperature_t temperature; // int32_t 4 mdegrK (0-2 MdegK) ambient temperature
pressure_t cylinderpressure; // int32_t 4 mbar (0-2 Mbar) main cylinder pressure
pressure_t diluentpressure; // int32_t 4 mbar (0-2 Mbar) CCR diluent pressure (rebreather)
pressure_t o2cylinderpressure; // int32_t 4 mbar (0-2 Mbar) CCR o2 cylinder pressure (rebreather)
o2pressure_t setpoint; // uint16_t 2 mbar (0-65 bar) O2 partial pressure (will be setpoint)
o2pressure_t o2sensor[3]; // uint16_t 6 mbar (0-65 bar) Up to 3 PO2 sensor values (rebreather)
bearing_t bearing; // int16_t 2 degrees (-32k to 32k deg) compass bearing