diff --git a/Documentation/images/sensors-import.png b/Documentation/images/sensors-import.png index 53d42e026..c635d32a8 100644 Binary files a/Documentation/images/sensors-import.png and b/Documentation/images/sensors-import.png differ diff --git a/Documentation/images/sensors-moved.png b/Documentation/images/sensors-moved.png index 1bc2d9871..7a0caff8e 100644 Binary files a/Documentation/images/sensors-moved.png and b/Documentation/images/sensors-moved.png differ diff --git a/Documentation/images/sensors-newcylinder.png b/Documentation/images/sensors-newcylinder.png index 341e479d9..087602ac5 100644 Binary files a/Documentation/images/sensors-newcylinder.png and b/Documentation/images/sensors-newcylinder.png differ diff --git a/Documentation/user-manual.txt b/Documentation/user-manual.txt index 9077a7d06..2f12c5d50 100644 --- a/Documentation/user-manual.txt +++ b/Documentation/user-manual.txt @@ -1949,21 +1949,22 @@ When importing a dive _Subsurface_ generally has to make some assumptions when i of these assumptions is which cylinder a pressure sensor is attached to. The following dive is a sidemount dive with two deco cylinders. Each of the main cylinders has a pressure sensor attached to them. In this case _Subsurface_ only knows about 3 gasses and 2 sensors so it makes the assumption that the sensors -are attached to the first two cylinders, one bottom gas and one with deco gas. +are attached to the first two cylinders, one bottom gas and one with deco gas. For the cylinders with +attached sensors the cylinder index will be shown in the sensors column. image::images/sensors-import.png["FIGURE: Imported cylinders and sensors",align="center"] -To fix this, you can add a new unused bottom gas cylinder. +To fix this, you can add a new cylinder with bottom gas and pick the index for the deco cylinder in +the sensors drop down. image::images/sensors-newcylinder.png["FIGURE: New cylinder added for sensor move",align="center"] -To then move the sensor from the 2nd cylinder to the newly added one replace the text *Select one of these cylinders: 0,1* -with *1* and press Enter. +After this change the second sensor will be attached to the fourth cylinder and the two deco cylinders +won't have any cylinders attached. image::images/sensors-moved.png["FIGURE: Sensor moved to new cylinder",align="center"] -The sensor will then be associated with this new cylinder and the profile graph will be updated to -reflect this change. +The profile graph will also be updated to reflect this change. [[S_sSCR_dives]] ==== Passive semi-closed circuit rebreather (pSCR) dives