Unify sample pressure and o2pressure as pressure[2] array
We currently carry two pressures around for all the samples and plot info, but the second pressure is reserved for CCR dives as the O2 cylinder pressure. That's kind of annoying when we *could* use it for regular sidemount dives as the secondary pressure. So start prepping for that instead: don't make it "pressure" and "o2pressure", make it just be an array of two pressure values. NOTE! This is purely mindless prepwork. It literally just does a search-and-replace, keeping the exact same semantics, so "pressure[1]" is still just O2 pressure. But at some future date, we can now start using it for a second sensor value for sidemount instead. Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
parent
94d8abd1a2
commit
11a0c0cc70
17 changed files with 68 additions and 68 deletions
|
@ -32,7 +32,7 @@ QVariant DivePlotDataModel::data(const QModelIndex &index, int role) const
|
|||
case TIME:
|
||||
return item.sec;
|
||||
case PRESSURE:
|
||||
return item.pressure[0];
|
||||
return item.pressure[0][0];
|
||||
case TEMPERATURE:
|
||||
return item.temperature;
|
||||
case COLOR:
|
||||
|
@ -42,9 +42,9 @@ QVariant DivePlotDataModel::data(const QModelIndex &index, int role) const
|
|||
case CYLINDERINDEX:
|
||||
return item.cylinderindex;
|
||||
case SENSOR_PRESSURE:
|
||||
return item.pressure[0];
|
||||
return item.pressure[0][0];
|
||||
case INTERPOLATED_PRESSURE:
|
||||
return item.pressure[1];
|
||||
return item.pressure[0][1];
|
||||
case CEILING:
|
||||
return item.ceiling;
|
||||
case SAC:
|
||||
|
|
Loading…