Do not run the deco calculations in the mobile app

We don't show the calculated ceilings and calculating them is compute
intensive.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
Dirk Hohndel 2016-02-05 20:45:18 -08:00
parent 7f70802b90
commit 130f4cd7ac
4 changed files with 12 additions and 1 deletions

View file

@ -854,6 +854,7 @@ static void setup_gas_sensor_pressure(struct dive *dive, struct divecomputer *dc
} while ((secondary = secondary->next) != NULL);
}
#ifndef SUBSURFACE_MOBILE
/* calculate DECO STOP / TTS / NDL */
static void calculate_ndl_tts(struct plot_data *entry, struct dive *dive, double surface_pressure)
{
@ -1067,7 +1068,7 @@ void calculate_deco_information(struct dive *dive, struct divecomputer *dc, stru
dump_tissues();
#endif
}
#endif
/* Function calculate_ccr_po2: This function takes information from one plot_data structure (i.e. one point on
* the dive profile), containing the oxygen sensor values of a CCR system and, for that plot_data structure,
@ -1223,7 +1224,9 @@ static void debug_print_profiledata(struct plot_info *pi)
void create_plot_info_new(struct dive *dive, struct divecomputer *dc, struct plot_info *pi, bool fast)
{
int o2, he, o2max;
#ifndef SUBSURFACE_MOBILE
init_decompression(dive);
#endif
/* Create the new plot data */
free((void *)last_pi_entry_new);
@ -1251,7 +1254,9 @@ void create_plot_info_new(struct dive *dive, struct divecomputer *dc, struct plo
}
fill_o2_values(dc, pi, dive); /* .. and insert the O2 sensor data having 0 values. */
calculate_sac(dive, pi); /* Calculate sac */
#ifndef SUBSURFACE_MOBILE
calculate_deco_information(dive, dc, pi, false); /* and ceiling information, using gradient factor values in Preferences) */
#endif
calculate_gas_information_new(dive, pi); /* Calculate gas partial pressures */
#ifdef DEBUG_GAS