user manual: p02 setting in Available Gases dialog is not possible

The manual suggests that in the  Available Gases dialog of the planner, setting of
pO2 is possible. This is not the case, and changed the text accordingly.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
This commit is contained in:
Jan Mulder 2017-03-21 11:46:45 +01:00 committed by Dirk Hohndel
parent d7ba41fe0f
commit 1355687b88

View file

@ -3582,8 +3582,9 @@ in the _Rates_ section of the dive setup.
pressure for oxygen needs to be specified for the
bottom part of the dive (_bottom po2_) as well as for the decompression part of the dive (_deco po2_).
Commonly used values are 1.4 bar for the bottom part of the dive and 1.6 bar for any decompression
stages. Normally, a partial pressure of 1.6 bar is not exceeded. pO~2~ settings and the depth at which switching to a gas takes place can also be edited in the
_Available Gases_ dialog. Normally the planner decides on switching to a new gas when, during
stages. Normally, a partial pressure of 1.6 bar is not exceeded. The depth at which switching to a gas
takes place can be edited in the
_Available Gases_ dialog. Normally, the planner decides on switching to a new gas when, during
ascent, the partial pressure of the new gas has decreased to 1.6 bar.
*c) Gas management*: With open-circuit dives this is a primary