Update tests to use cleaner CSV parsing "API"

Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
Miika Turkia 2015-08-27 17:36:24 +03:00 committed by Dirk Hohndel
parent 8e08fdcc85
commit 14999341e0

View file

@ -146,24 +146,45 @@ void TestParse::testParseCompareDM4Output()
void TestParse::testParseHUDC()
{
char *params[37];
int pnr = 0;
params[pnr++] = strdup("timeField");
params[pnr++] = intdup(0);
params[pnr++] = strdup("depthField");
params[pnr++] = intdup(1);
params[pnr++] = strdup("tempField");
params[pnr++] = intdup(5);
params[pnr++] = strdup("po2Field");
params[pnr++] = intdup(-1);
params[pnr++] = strdup("o2sensor1Field");
params[pnr++] = intdup(-1);
params[pnr++] = strdup("o2sensor2Field");
params[pnr++] = intdup(-1);
params[pnr++] = strdup("o2sensor3Field");
params[pnr++] = intdup(-1);
params[pnr++] = strdup("cnsField");
params[pnr++] = intdup(-1);
params[pnr++] = strdup("ndlField");
params[pnr++] = intdup(2);
params[pnr++] = strdup("ttsField");
params[pnr++] = intdup(-1);
params[pnr++] = strdup("stopdepthField");
params[pnr++] = intdup(-1);
params[pnr++] = strdup("pressureField");
params[pnr++] = intdup(-1);
params[pnr++] = strdup("setpointFiend");
params[pnr++] = intdup(-1);
params[pnr++] = strdup("separatorIndex");
params[pnr++] = intdup(2);
params[pnr++] = strdup("units");
params[pnr++] = intdup(0);
params[pnr++] = strdup("hw");
params[pnr++] = strdup("\"DC text\"");
params[pnr++] = NULL;
QCOMPARE(parse_csv_file(SUBSURFACE_SOURCE "/dives/TestDiveSeabearHUDC.csv",
0, // sample time
1, // sample depth
5, // sample temperature
-1, // sample pO₂
-1, // sample sensor1 pO₂
-1, // sample sensor2 pO₂
-1, // sample sensor3 pO₂
-1, // sample cns
2, // sample ndl
-1, // sample tts
-1, // sample stopdepth
-1, // sample pressure
-1, // smaple setpoint
2, // separator index
"csv", // XSLT template
0, // units
"\"DC text\""), 0);
params, pnr - 1, "csv"), 0);
/*