	Don't use "get_volume_string()" for cylinder size string
We had two totally different usage cases for "get_volume_string()": one that did the obvious "show this volume as a string", and one that tried to show a cylinder size. The function used a magic third argument (the working pressure of the cylinder) to distinguish between the two cases, but it still got it wrong. A metric cylinder doesn't necessarily have a working pressure at all, and the size is a wet size in liters. We'd pass in zero as the working pressure, and if the volume units were set to cubic feet, the logic in "get_volume_string()" would happily convert the metric wet size into the wet size in cubic feet. But that's completely wrong. An imperial cylinder size simply isn't a wet size. If you don't have a working pressure, you cannot convert the cylinder size to cubic feet. End of story. So instead of having "get_volume_string()" have magical behavior depending on working pressure, and getting it wrong anyway, just make get_volume_string do a pure volume conversion, and create a whole new function for showing the size of a cylinder. Now, if the cylinder doesn't have a working pressure, we just show the metric size, even if the user had asked for cubic feet. [Dirk Hohndel: added call to translation functions for the units] Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
		
							parent
							
								
									7ebc31c1ec
								
							
						
					
					
						commit
						288aff9dbb
					
				
					 4 changed files with 30 additions and 12 deletions
				
			
		| 
						 | 
				
			
			@ -23,6 +23,32 @@ CylindersModel *CylindersModel::instance()
 | 
			
		|||
	return self.data();
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
static QString get_cylinder_string(cylinder_t *cyl)
 | 
			
		||||
{
 | 
			
		||||
	QString unit;
 | 
			
		||||
	int decimals;
 | 
			
		||||
	unsigned int ml = cyl->type.size.mliter;
 | 
			
		||||
	pressure_t wp = cyl->type.workingpressure;
 | 
			
		||||
	double value;
 | 
			
		||||
 | 
			
		||||
	// We cannot use "get_volume_units()", because even when
 | 
			
		||||
	// using imperial units we may need to show the size in
 | 
			
		||||
	// liters: if we don't have a working pressure, we cannot
 | 
			
		||||
	// convert the cylinder size to cuft.
 | 
			
		||||
	if (wp.mbar && prefs.units.volume == units::CUFT) {
 | 
			
		||||
		value = ml_to_cuft(ml) * bar_to_atm(wp.mbar / 1000.0);
 | 
			
		||||
		decimals = (value > 20.0) ? 0 : (value > 2.0) ? 1 : 2;
 | 
			
		||||
		unit = CylindersModel::tr("cuft");
 | 
			
		||||
	} else {
 | 
			
		||||
		value = ml / 1000.0;
 | 
			
		||||
		decimals = 1;
 | 
			
		||||
		unit = CylindersModel::tr("ℓ");
 | 
			
		||||
	}
 | 
			
		||||
 | 
			
		||||
	return QString("%1").arg(value, 0, 'f', decimals) + unit;
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
static QVariant percent_string(fraction_t fraction)
 | 
			
		||||
{
 | 
			
		||||
	int permille = fraction.permille;
 | 
			
		||||
| 
						 | 
				
			
			@ -78,7 +104,7 @@ QVariant CylindersModel::data(const QModelIndex &index, int role) const
 | 
			
		|||
			break;
 | 
			
		||||
		case SIZE:
 | 
			
		||||
			if (cyl->type.size.mliter)
 | 
			
		||||
				ret = get_volume_string(cyl->type.size, true, cyl->type.workingpressure.mbar);
 | 
			
		||||
				ret = get_cylinder_string(cyl);
 | 
			
		||||
			break;
 | 
			
		||||
		case WORKINGPRESS:
 | 
			
		||||
			if (cyl->type.workingpressure.mbar)
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||
| 
						 | 
				
			
			@ -19,7 +19,7 @@ QString get_weight_unit();
 | 
			
		|||
QString get_cylinder_used_gas_string(cylinder_t *cyl, bool showunit = false);
 | 
			
		||||
QString get_temperature_string(temperature_t temp, bool showunit = false);
 | 
			
		||||
QString get_temp_unit();
 | 
			
		||||
QString get_volume_string(volume_t volume, bool showunit = false, int mbar = 0);
 | 
			
		||||
QString get_volume_string(volume_t volume, bool showunit = false);
 | 
			
		||||
QString get_volume_unit();
 | 
			
		||||
QString get_pressure_string(pressure_t pressure, bool showunit = false);
 | 
			
		||||
QString get_pressure_unit();
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||
| 
						 | 
				
			
			@ -678,19 +678,11 @@ QString get_temp_unit()
 | 
			
		|||
		return QString(UTF8_DEGREE "F");
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
QString get_volume_string(volume_t volume, bool showunit, int mbar)
 | 
			
		||||
QString get_volume_string(volume_t volume, bool showunit)
 | 
			
		||||
{
 | 
			
		||||
	const char *unit;
 | 
			
		||||
	int decimals;
 | 
			
		||||
	double value = get_volume_units(volume.mliter, &decimals, &unit);
 | 
			
		||||
	if (mbar) {
 | 
			
		||||
		// we are showing a tank size
 | 
			
		||||
		// fix the weird imperial way of denominating size and provide
 | 
			
		||||
		// reasonable number of decimals
 | 
			
		||||
		if (prefs.units.volume == units::CUFT)
 | 
			
		||||
			value *= bar_to_atm(mbar / 1000.0);
 | 
			
		||||
		decimals = (value > 20.0) ? 0 : (value > 2.0) ? 1 : 2;
 | 
			
		||||
	}
 | 
			
		||||
	return QString("%1%2").arg(value, 0, 'f', decimals).arg(showunit ? unit : "");
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||
| 
						 | 
				
			
			@ -26,7 +26,7 @@ static QString getFormattedCylinder(struct dive *dive, unsigned int idx)
 | 
			
		|||
	if (!desc && idx > 0)
 | 
			
		||||
		return QString(EMPTY_DIVE_STRING);
 | 
			
		||||
	QString fmt = desc ? QString(desc) : QObject::tr("unknown");
 | 
			
		||||
	fmt += ", " + get_volume_string(cyl->type.size, true, 0);
 | 
			
		||||
	fmt += ", " + get_volume_string(cyl->type.size, true);
 | 
			
		||||
	fmt += ", " + get_pressure_string(cyl->type.workingpressure, true);
 | 
			
		||||
	fmt += ", " + get_pressure_string(cyl->start, false) + " - " + get_pressure_string(cyl->end, true);
 | 
			
		||||
	fmt += ", " + get_gas_string(cyl->gasmix);
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||