Shearwater import: support for DC reported ceiling

This adds support for DC reported ceiling when importing the Shearwater
Desktop database. Both AI and non-AI versions are tested, but not all
possible paths. For non-AI the DC reported ceiling was from
firstStopDepth and for the AI version it was from the decoCeiling field.

I do not currently know when each of these fields are used, but at least
this works on my test data.

Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
This commit is contained in:
Miika Turkia 2018-05-27 09:06:09 +03:00 committed by Lubomir I. Ivanov
parent ddd35bc941
commit 295c63211c

View file

@ -97,8 +97,24 @@ extern int shearwater_profile_sample(void *handle, int columns, char **data, cha
cur_sample->ndl.seconds = atoi(data[4]) * 60;
if (data[5])
cur_sample->cns = atoi(data[5]);
if (data[6])
cur_sample->stopdepth.mm = metric ? atoi(data[6]) * 1000 : feet_to_mm(atoi(data[6]));
if (data[6]) {
if (atoi(data[6]) > 0) {
cur_sample->stopdepth.mm = metric ? atoi(data[6]) * 1000 : feet_to_mm(atoi(data[6]));
cur_sample->in_deco = 1;
} else if (data[7]) {
if (atoi(data[7]) > 0) {
cur_sample->stopdepth.mm = metric ? atoi(data[7]) * 1000 : feet_to_mm(atoi(data[7]));
if (data[8]) {
cur_sample->stoptime.seconds = atoi(data[8]) * 60;
}
cur_sample->in_deco = 1;
} else {
cur_sample->in_deco = 0;
}
} else {
cur_sample->in_deco = 0;
}
}
/* We don't actually have data[3], but it should appear in the
* SQL query at some point.
@ -130,8 +146,24 @@ extern int shearwater_ai_profile_sample(void *handle, int columns, char **data,
cur_sample->ndl.seconds = atoi(data[4]) * 60;
if (data[5])
cur_sample->cns = atoi(data[5]);
if (data[6])
cur_sample->stopdepth.mm = metric ? atoi(data[6]) * 1000 : feet_to_mm(atoi(data[6]));
if (data[6]) {
if (atoi(data[6]) > 0) {
cur_sample->stopdepth.mm = metric ? atoi(data[6]) * 1000 : feet_to_mm(atoi(data[6]));
cur_sample->in_deco = 1;
} else if (data[9]) {
if (atoi(data[9]) > 0) {
cur_sample->stopdepth.mm = metric ? atoi(data[9]) * 1000 : feet_to_mm(atoi(data[9]));
if (data[10]) {
cur_sample->stoptime.seconds = atoi(data[10]) * 60;
}
cur_sample->in_deco = 1;
} else {
cur_sample->in_deco = 0;
}
} else {
cur_sample->in_deco = 0;
}
}
/* Weird unit conversion but seems to produce correct results.
* Also missing values seems to be reported as a 4092 (564 bar) */
@ -165,8 +197,8 @@ extern int shearwater_dive(void *param, int columns, char **data, char **column)
int retval = 0;
sqlite3 *handle = (sqlite3 *)param;
char *err = NULL;
char get_profile_template[] = "select currentTime,currentDepth,waterTemp,averagePPO2,currentNdl,CNSPercent,decoCeiling from dive_log_records where diveLogId=%d";
char get_profile_template_ai[] = "select currentTime,currentDepth,waterTemp,averagePPO2,currentNdl,CNSPercent,decoCeiling,aiSensor0_PressurePSI,aiSensor1_PressurePSI from dive_log_records where diveLogId = %d";
char get_profile_template[] = "select currentTime,currentDepth,waterTemp,averagePPO2,currentNdl,CNSPercent,decoCeiling,firstStopDepth,firstStopTime from dive_log_records where diveLogId=%d";
char get_profile_template_ai[] = "select currentTime,currentDepth,waterTemp,averagePPO2,currentNdl,CNSPercent,decoCeiling,aiSensor0_PressurePSI,aiSensor1_PressurePSI,firstStopDepth,firstStopTime from dive_log_records where diveLogId = %d";
char get_cylinder_template[] = "select fractionO2,fractionHe from dive_log_records where diveLogId = %d group by fractionO2,fractionHe";
char get_changes_template[] = "select a.currentTime,a.fractionO2,a.fractionHe from dive_log_records as a,dive_log_records as b where (a.id - 1) = b.id and (a.fractionO2 != b.fractionO2 or a.fractionHe != b.fractionHe) and a.diveLogId=b.divelogId and a.diveLogId = %d";
char get_mode_template[] = "select distinct currentCircuitSetting from dive_log_records where diveLogId = %d";