Fix potential double/float to int rounding errors

Not using lrint(f) when converting double/float to int
creates rounding errors.
This error was detected by TestParse::testParseDM4 failure
on Windows. It was creating rounding inconsistencies
on Linux too, see change in TestDiveDM4.xml.

Enable -Wfloat-conversion for gcc version greater than 4.9.0

Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
This commit is contained in:
Jeremie Guichard 2017-03-09 23:07:30 +07:00
parent 406e4287eb
commit 2b06a0b223
20 changed files with 109 additions and 100 deletions

View file

@ -220,7 +220,7 @@ void fill_default_cylinder(cylinder_t *cyl)
} else {
cyl->type.workingpressure.mbar = psi_to_mbar(ti->psi);
if (ti->psi)
cyl->type.size.mliter = cuft_to_l(ti->cuft) * 1000 / bar_to_atm(psi_to_bar(ti->psi));
cyl->type.size.mliter = lrint(cuft_to_l(ti->cuft) * 1000 / bar_to_atm(psi_to_bar(ti->psi)));
}
// MOD of air
cyl->depth = gas_mod(&cyl->gasmix, pO2, &displayed_dive, 1);
@ -241,12 +241,12 @@ static void update_cylinder_pressure(struct dive *d, int old_depth, int new_dept
if (!cyl)
return;
mean_depth.mm = (old_depth + new_depth) / 2;
gas_used.mliter = depth_to_atm(mean_depth.mm, d) * sac / 60 * duration * factor / 1000;
gas_used.mliter = lrint(depth_to_atm(mean_depth.mm, d) * sac / 60 * duration * factor / 1000);
cyl->gas_used.mliter += gas_used.mliter;
if (in_deco)
cyl->deco_gas_used.mliter += gas_used.mliter;
if (cyl->type.size.mliter) {
delta_p.mbar = gas_used.mliter * 1000.0 / cyl->type.size.mliter * gas_compressibility_factor(&cyl->gasmix, cyl->end.mbar / 1000.0);
delta_p.mbar = lrint(gas_used.mliter * 1000.0 / cyl->type.size.mliter * gas_compressibility_factor(&cyl->gasmix, cyl->end.mbar / 1000.0));
cyl->end.mbar -= delta_p.mbar;
}
}
@ -830,7 +830,7 @@ static void add_plan_to_notes(struct diveplan *diveplan, struct dive *dive, bool
depth_unit);
/* Get SAC values and units for printing it in gas consumption */
float bottomsacvalue, decosacvalue;
double bottomsacvalue, decosacvalue;
int sacdecimals;
const char* sacunit;
@ -858,10 +858,10 @@ static void add_plan_to_notes(struct diveplan *diveplan, struct dive *dive, bool
volume = get_volume_units(cyl->gas_used.mliter, NULL, &unit);
deco_volume = get_volume_units(cyl->deco_gas_used.mliter, NULL, &unit);
if (cyl->type.size.mliter) {
int remaining_gas = (double)cyl->end.mbar * cyl->type.size.mliter / 1000.0 / gas_compressibility_factor(&cyl->gasmix, cyl->end.mbar / 1000.0);
int remaining_gas = lrint((double)cyl->end.mbar * cyl->type.size.mliter / 1000.0 / gas_compressibility_factor(&cyl->gasmix, cyl->end.mbar / 1000.0));
double deco_pressure_bar = isothermal_pressure(&cyl->gasmix, 1.0, remaining_gas + cyl->deco_gas_used.mliter, cyl->type.size.mliter)
- cyl->end.mbar / 1000.0;
deco_pressure = get_pressure_units(1000.0 * deco_pressure_bar, &pressure_unit);
deco_pressure = get_pressure_units(lrint(1000.0 * deco_pressure_bar), &pressure_unit);
pressure = get_pressure_units(cyl->start.mbar - cyl->end.mbar, &pressure_unit);
/* Warn if the plan uses more gas than is available in a cylinder