Change calls to rint into lrint avoiding conversion warnings
Using gcc option "-Wfloat-conversion" is useful to catch potential conversion errors (where lrint should be used). rint returns double and still raises the same warning, this is why this change updates all rint calls to lrint. In few places, where input type is a float, corresponding lrinf is used. Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
This commit is contained in:
parent
9c2619ea3b
commit
406e4287eb
21 changed files with 101 additions and 101 deletions
12
core/dive.c
12
core/dive.c
|
|
@ -243,15 +243,15 @@ double get_volume_units(unsigned int ml, int *frac, const char **units)
|
|||
int units_to_sac(double volume)
|
||||
{
|
||||
if (get_units()->volume == CUFT)
|
||||
return rint(cuft_to_l(volume) * 1000.0);
|
||||
return lrint(cuft_to_l(volume) * 1000.0);
|
||||
else
|
||||
return rint(volume * 1000);
|
||||
return lrint(volume * 1000);
|
||||
}
|
||||
|
||||
unsigned int units_to_depth(double depth)
|
||||
{
|
||||
if (get_units()->length == METERS)
|
||||
return rint(depth * 1000);
|
||||
return lrint(depth * 1000);
|
||||
return feet_to_mm(depth);
|
||||
}
|
||||
|
||||
|
|
@ -872,7 +872,7 @@ int gas_volume(cylinder_t *cyl, pressure_t p)
|
|||
{
|
||||
double bar = p.mbar / 1000.0;
|
||||
double z_factor = gas_compressibility_factor(&cyl->gasmix, bar);
|
||||
return rint(cyl->type.size.mliter * bar_to_atm(bar) / z_factor);
|
||||
return lrint(cyl->type.size.mliter * bar_to_atm(bar) / z_factor);
|
||||
}
|
||||
|
||||
/*
|
||||
|
|
@ -1019,7 +1019,7 @@ static void match_standard_cylinder(cylinder_type_t *type)
|
|||
default:
|
||||
return;
|
||||
}
|
||||
len = snprintf(buffer, sizeof(buffer), fmt, (int)rint(cuft));
|
||||
len = snprintf(buffer, sizeof(buffer), fmt, (int)lrint(cuft));
|
||||
p = malloc(len + 1);
|
||||
if (!p)
|
||||
return;
|
||||
|
|
@ -1056,7 +1056,7 @@ static void sanitize_cylinder_type(cylinder_type_t *type)
|
|||
volume_of_air = cuft_to_l(type->size.mliter);
|
||||
/* milliliters at 1 atm: not corrected for compressibility! */
|
||||
volume = volume_of_air / bar_to_atm(bar);
|
||||
type->size.mliter = rint(volume);
|
||||
type->size.mliter = lrint(volume);
|
||||
}
|
||||
|
||||
/* Ok, we have both size and pressure: try to match a description */
|
||||
|
|
|
|||
Loading…