Don't access gasmix.o2.fraction
Air is a special gas that does not contain oxygen according to gasmix.o2.fraction. If you want to use the fo2, you need to use get_o2() to treat this special case correctly. This fixes a bug when setting the MND of a gas containing 21% oxygen when o2 is considered not narcotic. Reported-by: Christoph Gruen <gruen.christoph@gmail.com> Signed-off-by: Robert C. Helling <helling@atdotde.de>
This commit is contained in:
parent
5e9ee9febb
commit
41258647d2
8 changed files with 9280 additions and 9276 deletions
|
@ -445,11 +445,11 @@ bool CylindersModel::setData(const QModelIndex &index, const QVariant &value, in
|
|||
if (QString::compare(qPrintable(vString), "*") == 0) {
|
||||
cyl.bestmix_he = true;
|
||||
// Calculate fO2 for max. depth
|
||||
cyl.gasmix.he = best_he(d->maxdepth, d, prefs.o2narcotic, cyl.gasmix.o2);
|
||||
cyl.gasmix.he = best_he(d->maxdepth, d, prefs.o2narcotic, make_fraction(get_o2(cyl.gasmix)));
|
||||
} else {
|
||||
cyl.bestmix_he = false;
|
||||
// Calculate fHe for input depth
|
||||
cyl.gasmix.he = best_he(string_to_depth(qPrintable(vString)), d, prefs.o2narcotic, cyl.gasmix.o2);
|
||||
cyl.gasmix.he = best_he(string_to_depth(qPrintable(vString)), d, prefs.o2narcotic, make_fraction(get_o2(cyl.gasmix)));
|
||||
}
|
||||
type = Command::EditCylinderType::GASMIX;
|
||||
break;
|
||||
|
|