Document the heat map in the manual.
Signed-off-by: Robert C. Helling <helling@atdotde.de> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
parent
fa2fcc4024
commit
434c27525a
2 changed files with 12 additions and 8 deletions
|
@ -2214,13 +2214,17 @@ image::images/ShowCylinders_f20.jpg["Figure: Cylinder use graph",align="center"]
|
||||||
[icon="images/icons/tissues.jpg"]
|
[icon="images/icons/tissues.jpg"]
|
||||||
|
|
||||||
[NOTE]
|
[NOTE]
|
||||||
Display inert gas tissue pressures relative to ambient inert gas pressure (horizontal grey line).
|
Display that tissue heat-map. This is a representation of the inert
|
||||||
Tissue pressures are calculated using the Bühlmann ZH-L16 algorithm and are displayed as lines ranging from
|
gas pressures in the different tissues of a decompression
|
||||||
green (faster tissues) to blue (slower tissues).
|
model. Faster tissues are displayed on top while the slower tissues
|
||||||
The black line, graphed above the ambient pressure, is the maximum allowable tissue supersaturation (pressure limit) derived
|
are shown on the bottom. The color is a representation of the inert
|
||||||
from the gradient factors specified in the *Preferences*. For
|
gas loading of the tissue. Blue colors indicate the tissue's inert gas
|
||||||
divers doing planned decompression diving, efficient rates of offgassing are obtained with tissue pressures
|
pressure is below the ambient pressure and the tissue is currently
|
||||||
between the ambient inert gas pressure (grey line) and the pressure limit (black line). This display is a representation
|
on-gasing. The more red the color is, the higher the pressure is above
|
||||||
|
the ambient pressure and the tissue is off-gassing potentially
|
||||||
|
releasing inert gases to the environment which can be the cause for
|
||||||
|
the formation of inert gas bubbles.
|
||||||
|
This display is a representation
|
||||||
of the tissue pressures during the whole dive. In contrast, the xref:S_gas_pressure_graph[Gas Pressure Graph] in the *Information Box*
|
of the tissue pressures during the whole dive. In contrast, the xref:S_gas_pressure_graph[Gas Pressure Graph] in the *Information Box*
|
||||||
on the *Dive Profile* is an instantaneous reflection of tissue pressures at the moment in
|
on the *Dive Profile* is an instantaneous reflection of tissue pressures at the moment in
|
||||||
time, at the position of the cursor on the dive profile.
|
time, at the position of the cursor on the dive profile.
|
||||||
|
|
|