mirror of
https://github.com/subsurface/subsurface.git
synced 2025-02-19 22:16:15 +00:00
Cleanup: replace pressure reading macros by inline functions
Replace the INTERPOLATED_PRESSURE and SENSOR_PRESSURE macros by inline functions. Generate a common inline function that reads a pressure value for a dynamic sensor. Not all SENSOR_PRESSURE macros can be replaced, because the macro is also used to set the value and C sadly doesn't know the concept of "return reference from a function". Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This commit is contained in:
parent
29005b578d
commit
469cc68b02
4 changed files with 26 additions and 12 deletions
|
@ -1535,19 +1535,19 @@ void ProfileWidget2::contextMenuEvent(QContextMenuEvent *event)
|
|||
if (gasChangeEntry + 1 <= plotInfo.entry + plotInfo.nr) {
|
||||
newGasEntry = gasChangeEntry + 1;
|
||||
qDebug() << "after gas change at " << newGasEntry->sec << ": sensor pressure" << newGasEntry->pressure[0] << "interpolated" << newGasEntry->pressure[1];
|
||||
if (SENSOR_PRESSURE(gasChangeEntry) == 0 || displayed_dive.cylinder[gasChangeEntry->sensor[0]].sample_start.mbar == 0) {
|
||||
if (get_plot_sensor_pressure(gasChangeEntry) == 0 || displayed_dive.cylinder[gasChangeEntry->sensor[0]].sample_start.mbar == 0) {
|
||||
// if we have no sensorpressure or if we have no pressure from samples we can assume that
|
||||
// we only have interpolated pressure (the pressure in the entry may be stored in the sensor
|
||||
// pressure field if this is the first or last entry for this tank... see details in gaspressures.c
|
||||
pressure_t pressure;
|
||||
pressure.mbar = INTERPOLATED_PRESSURE(gasChangeEntry) ? : SENSOR_PRESSURE(gasChangeEntry);
|
||||
pressure.mbar = get_plot_interpolated_pressure(gasChangeEntry) ? : get_plot_sensor_pressure(gasChangeEntry);
|
||||
QAction *adjustOldPressure = m.addAction(tr("Adjust pressure of cyl. %1 (currently interpolated as %2)")
|
||||
.arg(gasChangeEntry->sensor[0] + 1).arg(get_pressure_string(pressure)));
|
||||
}
|
||||
if (SENSOR_PRESSURE(newGasEntry) == 0 || displayed_dive.cylinder[newGasEntry->sensor[0]].sample_start.mbar == 0) {
|
||||
if (get_plot_sensor_pressure(newGasEntry) == 0 || displayed_dive.cylinder[newGasEntry->sensor[0]].sample_start.mbar == 0) {
|
||||
// we only have interpolated press -- see commend above
|
||||
pressure_t pressure;
|
||||
pressure.mbar = INTERPOLATED_PRESSURE(newGasEntry) ? : SENSOR_PRESSURE(newGasEntry);
|
||||
pressure.mbar = get_plot_interpolated_pressure(newGasEntry) ? : get_plot_sensor_pressure(newGasEntry);
|
||||
QAction *adjustOldPressure = m.addAction(tr("Adjust pressure of cyl. %1 (currently interpolated as %2)")
|
||||
.arg(newGasEntry->sensor[0] + 1).arg(get_pressure_string(pressure)));
|
||||
}
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue