Even more places with pressure and volume conversions
Amazing at how many spots we are re-implementing the wheel. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
parent
5698057951
commit
485b02937d
5 changed files with 16 additions and 16 deletions
|
@ -425,7 +425,7 @@ static void water_pressure(char *buffer, void *_depth)
|
|||
if (!val.fp)
|
||||
break;
|
||||
/* cbar to atm */
|
||||
atm = (val.fp / 100) / 1.01325;
|
||||
atm = bar_to_atm(val.fp * 10);
|
||||
/*
|
||||
* atm to cm. Why not mm? The precision just isn't
|
||||
* there.
|
||||
|
@ -1122,9 +1122,9 @@ static void match_standard_cylinder(cylinder_type_t *type)
|
|||
if (type->description)
|
||||
return;
|
||||
|
||||
cuft = type->size.mliter / 28317.0;
|
||||
cuft = ml_to_cuft(type->size.mliter);
|
||||
cuft *= to_ATM(type->workingpressure);
|
||||
psi = type->workingpressure.mbar / 68.95;
|
||||
psi = to_PSI(type->workingpressure);
|
||||
|
||||
switch (psi) {
|
||||
case 2300 ... 2500: /* 2400 psi: LP tank */
|
||||
|
@ -1177,7 +1177,8 @@ static void sanitize_cylinder_type(cylinder_type_t *type)
|
|||
return;
|
||||
|
||||
if (input_units.volume == CUFT || import_source == SUUNTO) {
|
||||
volume_of_air = type->size.mliter * 28.317; /* milli-cu ft to milliliter */
|
||||
/* confusing - we don't really start from ml but millicuft !*/
|
||||
volume_of_air = cuft_to_l(type->size.mliter);
|
||||
atm = to_ATM(type->workingpressure); /* working pressure in atm */
|
||||
volume = volume_of_air / atm; /* milliliters at 1 atm: "true size" */
|
||||
type->size.mliter = volume + 0.5;
|
||||
|
|