mirror of
https://github.com/subsurface/subsurface.git
synced 2025-02-19 22:16:15 +00:00
Describe new CCR features in user manual
Signed-off-by: Robert C. Helling <helling@atdotde.de> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
parent
299a85f668
commit
4921c28c4d
1 changed files with 27 additions and 4 deletions
|
@ -1878,12 +1878,17 @@ during the dive. For more information external to this manual see:
|
||||||
|
|
||||||
The context menu for the Dive Profile is accessed by right-clicking while the
|
The context menu for the Dive Profile is accessed by right-clicking while the
|
||||||
mouse cursor is over the Dive Profile panel. The menu allows the creation of
|
mouse cursor is over the Dive Profile panel. The menu allows the creation of
|
||||||
Bookmarks or Gas Change Event markers other than the ones that might have been
|
Bookmarks or Gas Change Event markers or manual CCR set-point changes other than the ones that might have been
|
||||||
imported from a Dive Computer. Markers are placed against the depth profile line
|
imported from a Dive Computer. Markers are placed against the depth profile line
|
||||||
and with the time of the event set by where the mouse cursor was when the right
|
and with the time of the event set by where the mouse cursor was when the right
|
||||||
mouse button was initially clicked to bring up the menu. Gas Change events
|
mouse button was initially clicked to bring up the menu. Gas Change events
|
||||||
open a further selection of which gas is being switched to, the list based on
|
open a further selection of which gas is being switched to, the list based on
|
||||||
the available gases defined in the Equipment Tab. By right-clicking while over
|
the available gases defined in the Equipment Tab. Set-point change
|
||||||
|
events open a dialog allowing to choose the next set-point value. As
|
||||||
|
in the planner, a set-point value of zero indicates the diver is
|
||||||
|
breathing from an open circuit system while any non-zero value
|
||||||
|
indicates the use of a closed circuit reprether (CCR).
|
||||||
|
By right-clicking while over
|
||||||
an existing marker, the menu extends adding options to allow deletion of the
|
an existing marker, the menu extends adding options to allow deletion of the
|
||||||
marker or to allow all markers of that type to be hidden. Hidden events can be
|
marker or to allow all markers of that type to be hidden. Hidden events can be
|
||||||
restored to view by selecting Unhide all events from the context menu.
|
restored to view by selecting Unhide all events from the context menu.
|
||||||
|
@ -2666,7 +2671,18 @@ in the section <<S_CreateProfile,hand-creating a dive profile>>. These changes s
|
||||||
reflect the cylinders and gas compositions defined in the table with _Available Gases_.
|
reflect the cylinders and gas compositions defined in the table with _Available Gases_.
|
||||||
If two or more gases are used, automatic gas switches will be suggested during the ascent to
|
If two or more gases are used, automatic gas switches will be suggested during the ascent to
|
||||||
the surface. However, these changes can be deleted by right-clicking the gas change and by
|
the surface. However, these changes can be deleted by right-clicking the gas change and by
|
||||||
manually creating a gas change by right-clicking on the appropriate waypoint.
|
manually creating a gas change by right-clicking on the appropriate
|
||||||
|
waypoint.
|
||||||
|
|
||||||
|
- By entering a non-zero value in the "CC set point" column of the
|
||||||
|
dive planner points table that segment is assumed to use a closed
|
||||||
|
circuit rebreather (CCR) with the given set-point for oxygen partial
|
||||||
|
pressure. If the last manually entered segment is such a CCR
|
||||||
|
segment, the decompression phase is also computed assuming the diver
|
||||||
|
uses a CCR with the same set-point. If the last segment (however
|
||||||
|
short) is on open circuit (OC) indicated by a zero set-point the
|
||||||
|
decompression is comuted in OC mode. The planner only considers gas
|
||||||
|
changes in OC mode.
|
||||||
|
|
||||||
Below is an example of a dive plan to 45m using EAN26, followed by an ascent using EAN50
|
Below is an example of a dive plan to 45m using EAN26, followed by an ascent using EAN50
|
||||||
and using the settings as described above.
|
and using the settings as described above.
|
||||||
|
@ -2701,6 +2717,12 @@ To perform changes to a dive plan, select it on the *Dive List*. Then, in the ma
|
||||||
select _Log -> Re-plan dive_. This will open the selected dive plan within the dive planner,
|
select _Log -> Re-plan dive_. This will open the selected dive plan within the dive planner,
|
||||||
allowing changes to be made and saved as usual.
|
allowing changes to be made and saved as usual.
|
||||||
|
|
||||||
|
In addition there is the option "Save new". This keeps the original
|
||||||
|
planned dive and adds a (possibly modified) copy to the dive list. If
|
||||||
|
that copy is saved with the same start time as the original, the two
|
||||||
|
dives are considered two versions of the same dive and do not
|
||||||
|
influence each others decompression calculation (see next section).
|
||||||
|
|
||||||
=== Planning for repetitive dives
|
=== Planning for repetitive dives
|
||||||
|
|
||||||
Repetitive dives can easily be planned if the dates and start times of the
|
Repetitive dives can easily be planned if the dates and start times of the
|
||||||
|
@ -2733,7 +2755,8 @@ the _Print_ button in the dive planner. This prints the dive details and gas cal
|
||||||
in the _Dive Plan Details_ panel of the dive planner. However, after the plan has been saved, it is
|
in the _Dive Plan Details_ panel of the dive planner. However, after the plan has been saved, it is
|
||||||
represented in a way very similar to a dive log and the gas calculations cannot be
|
represented in a way very similar to a dive log and the gas calculations cannot be
|
||||||
accessed in the same way as during the planning process. The only way to print the
|
accessed in the same way as during the planning process. The only way to print the
|
||||||
dive plan is to use the _File->Print_ facility on the main menu in the same way as for dive logs.
|
dive plan is to use the _File->Print_ facility on the main menu in the
|
||||||
|
same way as for dive logs or by copy and paste to a word processor.
|
||||||
|
|
||||||
[[S_Configure]]
|
[[S_Configure]]
|
||||||
== Configuring a dive computer
|
== Configuring a dive computer
|
||||||
|
|
Loading…
Add table
Reference in a new issue