mirror of
https://github.com/subsurface/subsurface.git
synced 2024-11-28 05:00:20 +00:00
Use libdivecomputer tank size when available
If the gasmix of a tank is not the matching gasmix in the list of gasmixes, issue a warning (as so far we assume those are always in sync). This patch removes our own parsing of the sizes because Subsurface 4.3 will require libdivecomputer 0.5 so this should be enabled by the time the next release comes out, so let's just drop the redundant code. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
parent
1990dafda0
commit
4be7604634
1 changed files with 34 additions and 48 deletions
|
@ -51,59 +51,26 @@ struct atomics_gas_info {
|
|||
uint16_t endpressure; /* in psi */
|
||||
uint16_t totalconsumption; /* in liters */
|
||||
};
|
||||
#define COBALT_CFATPSI 1
|
||||
#define COBALT_CFATBAR 2
|
||||
#define COBALT_WETINDL 3
|
||||
|
||||
static bool get_tanksize(device_data_t *devdata, const unsigned char *data, cylinder_t *cyl, int idx)
|
||||
{
|
||||
/* I don't like this kind of match... I'd love to have an ID and
|
||||
* a firmware version or... something; and even better, just get
|
||||
* this from libdivecomputer */
|
||||
if (!strcmp(devdata->vendor, "Atomic Aquatics") &&
|
||||
!strcmp(devdata->product, "Cobalt")) {
|
||||
struct atomics_gas_info *atomics_gas_info;
|
||||
double airvolume;
|
||||
int mbar;
|
||||
|
||||
/* at least some quick sanity check to make sure this is the
|
||||
* right data */
|
||||
if (*(uint32_t *)data != 0xFFFEFFFE) {
|
||||
printf("incorrect header for Atomics dive\n");
|
||||
return false;
|
||||
}
|
||||
atomics_gas_info = (void *)(data + COBALT_HEADER);
|
||||
switch (atomics_gas_info[idx].tankspecmethod) {
|
||||
case COBALT_CFATPSI:
|
||||
airvolume = cuft_to_l(atomics_gas_info[idx].tanksize) * 1000.0;
|
||||
mbar = psi_to_mbar(atomics_gas_info[idx].workingpressure);
|
||||
cyl[idx].type.size.mliter = rint(airvolume / bar_to_atm(mbar / 1000.0));
|
||||
cyl[idx].type.workingpressure.mbar = mbar;
|
||||
break;
|
||||
case COBALT_CFATBAR:
|
||||
airvolume = cuft_to_l(atomics_gas_info[idx].tanksize) * 1000.0;
|
||||
mbar = atomics_gas_info[idx].workingpressure * 1000;
|
||||
cyl[idx].type.size.mliter = rint(airvolume / bar_to_atm(mbar / 1000.0));
|
||||
cyl[idx].type.workingpressure.mbar = mbar;
|
||||
break;
|
||||
case COBALT_WETINDL:
|
||||
cyl[idx].type.size.mliter = atomics_gas_info[idx].tanksize * 100;
|
||||
break;
|
||||
}
|
||||
return true;
|
||||
}
|
||||
return false;
|
||||
}
|
||||
|
||||
static int parse_gasmixes(device_data_t *devdata, struct dive *dive, dc_parser_t *parser, int ngases,
|
||||
const unsigned char *data)
|
||||
{
|
||||
static bool shown_warning = false;
|
||||
int i;
|
||||
int i, rc, ntanks = 0;
|
||||
|
||||
#if DC_VERSION_CHECK(0, 5, 0) && defined(DC_GASMIX_UNKNOWN)
|
||||
rc = dc_parser_get_field(parser, DC_FIELD_TANK_COUNT, 0, &ntanks);
|
||||
if (rc == DC_STATUS_SUCCESS) {
|
||||
if (ntanks != ngases) {
|
||||
shown_warning = true;
|
||||
report_error("different number of gases (%d) and tanks (%d)", ngases, ntanks);
|
||||
}
|
||||
}
|
||||
#endif
|
||||
|
||||
for (i = 0; i < ngases; i++) {
|
||||
int rc;
|
||||
dc_gasmix_t gasmix = { 0 };
|
||||
dc_tank_t tank = { 0 };
|
||||
int o2, he;
|
||||
|
||||
rc = dc_parser_get_field(parser, DC_FIELD_GASMIX, i, &gasmix);
|
||||
|
@ -134,10 +101,29 @@ static int parse_gasmixes(device_data_t *devdata, struct dive *dive, dc_parser_t
|
|||
dive->cylinder[i].gasmix.o2.permille = o2;
|
||||
dive->cylinder[i].gasmix.he.permille = he;
|
||||
|
||||
/* for the first tank, if there is no tanksize available from the
|
||||
* dive computer, fill in the default tank information (if set) */
|
||||
if (!get_tanksize(devdata, data, dive->cylinder, i) && i == 0)
|
||||
tank.volume = 0.0;
|
||||
#if DC_VERSION_CHECK(0, 5, 0) && defined(DC_GASMIX_UNKNOWN)
|
||||
if (i < ntanks) {
|
||||
rc = dc_parser_get_field(parser, DC_FIELD_TANK, 0, &tank);
|
||||
if (rc == DC_STATUS_SUCCESS) {
|
||||
if (tank.type == DC_TANKVOLUME_IMPERIAL) {
|
||||
dive->cylinder[i].type.size.mliter = rint(tank.volume * 1000);
|
||||
dive->cylinder[i].type.workingpressure.mbar = rint(tank.workpressure * 1000);
|
||||
} else if (tank.type == DC_TANKVOLUME_METRIC) {
|
||||
dive->cylinder[i].type.size.mliter = rint(tank.volume * 1000);
|
||||
}
|
||||
if (tank.gasmix != i) { // we don't handle this, yet
|
||||
shown_warning = true;
|
||||
report_error("gasmix %d for tank %d doesn't match", tank.gasmix, i);
|
||||
}
|
||||
}
|
||||
}
|
||||
#endif
|
||||
if (IS_FP_SAME(tank.volume, 0.0)) {
|
||||
/* for the first tank, if there is no tanksize available from the
|
||||
* dive computer, fill in the default tank information (if set) */
|
||||
fill_default_cylinder(&dive->cylinder[i]);
|
||||
}
|
||||
}
|
||||
return DC_STATUS_SUCCESS;
|
||||
}
|
||||
|
|
Loading…
Reference in a new issue