mirror of
https://github.com/subsurface/subsurface.git
synced 2025-02-19 22:16:15 +00:00
Maintain sensor index for uemis and liquivision
Previosuly they always used index 0 for the active sensor, use add_sample_pressure instead. Signed-off-by: Michael Andreen <michael@andreen.dev> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
parent
9b4263aa87
commit
4e92cb2567
2 changed files with 4 additions and 9 deletions
|
@ -343,8 +343,7 @@ static void parse_dives(int log_version, const unsigned char *buf, unsigned int
|
|||
sample->time.seconds = event.time;
|
||||
sample->depth.mm = array_uint16_le(ds + (d - 1) * 2) * 10; // cm->mm
|
||||
sample->temperature.mkelvin = C_to_mkelvin((float) array_uint16_le(ts + (d - 1) * 2) / 10); // dC->mK
|
||||
sample->sensor[0] = event.pressure.sensor;
|
||||
sample->pressure[0].mbar = event.pressure.mbar;
|
||||
add_sample_pressure(sample, event.pressure.sensor, event.pressure.mbar);
|
||||
finish_sample(dc);
|
||||
|
||||
break;
|
||||
|
@ -361,16 +360,14 @@ static void parse_dives(int log_version, const unsigned char *buf, unsigned int
|
|||
sample->time.seconds = sample_time;
|
||||
sample->depth.mm = depth_mm;
|
||||
sample->temperature.mkelvin = temp_mk;
|
||||
sample->sensor[0] = event.pressure.sensor;
|
||||
sample->pressure[0].mbar = event.pressure.mbar;
|
||||
add_sample_pressure(sample, event.pressure.sensor, event.pressure.mbar);
|
||||
finish_sample(dc);
|
||||
d++;
|
||||
|
||||
break;
|
||||
} else { // Event is prior to sample
|
||||
sample->time.seconds = event.time;
|
||||
sample->sensor[0] = event.pressure.sensor;
|
||||
sample->pressure[0].mbar = event.pressure.mbar;
|
||||
add_sample_pressure(sample, event.pressure.sensor, event.pressure.mbar);
|
||||
if (last_time == sample_time) {
|
||||
sample->depth.mm = depth_mm;
|
||||
sample->temperature.mkelvin = temp_mk;
|
||||
|
|
|
@ -359,9 +359,7 @@ void uemis_parse_divelog_binary(char *base64, void *datap)
|
|||
sample->time.seconds = u_sample->dive_time;
|
||||
sample->depth.mm = rel_mbar_to_depth(u_sample->water_pressure, dive);
|
||||
sample->temperature.mkelvin = C_to_mkelvin(u_sample->dive_temperature / 10.0);
|
||||
sample->sensor[0] = active;
|
||||
sample->pressure[0].mbar =
|
||||
(u_sample->tank_pressure_high * 256 + u_sample->tank_pressure_low) * 10;
|
||||
add_sample_pressure(sample, active, (u_sample->tank_pressure_high * 256 + u_sample->tank_pressure_low) * 10);
|
||||
sample->cns = u_sample->cns;
|
||||
uemis_event(dive, dc, sample, u_sample);
|
||||
finish_sample(dc);
|
||||
|
|
Loading…
Add table
Reference in a new issue