Connect preferences to the rest of the code

The biggest problem here was that bool has different sizes in C and C++
code. So using this in a structure shared between the two sides wasn't a
smart idea.

Instead I went with 'short', but that caused problems with Qt being to
smart for its own good and not doing the right thing when dealing with
'boolean' settings and a short value. This may be something in the way I
implemented things (as I doubt that something this fundamental would be
broken) but the workaround implemented here (explicitly using 0 or 1
depending on the value of the boolean) seems to work.

I also decided to get rid of the confusion of where gflow/gfhigh are
floating point (0..1) and when they are integers (0..100). We now use
integers anywhere outside of deco.c.

I also applied some serious spelling corrections to the preferences
dialog's ui file.

Finally, this enables the code that selects which partial pressure graph
to show.

Still to do: font size, metric/imperial logic

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
Dirk Hohndel 2013-05-28 11:21:27 -07:00
parent 8394828806
commit 4f53ad736d
10 changed files with 120 additions and 92 deletions

View file

@ -372,11 +372,11 @@ void MainWindow::readSettings()
GET_BOOL(v, "OTU", prefs.visible_cols.otu);
GET_BOOL(v, "MAXCNS", prefs.visible_cols.maxcns);
GET_BOOL(v, "SAC", prefs.visible_cols.sac);
settings.endGroup();
settings.beginGroup("TecDetails");
GET_BOOL(v, "po2graph", prefs.pp_graphs.po2);
GET_BOOL(v, "pn2graph", prefs.pp_graphs.pn2);
GET_BOOL(v, "phegraph", prefs.pp_graphs.phe);
settings.endGroup();
settings.beginGroup("TecDetails");
v = settings.value(QString("po2threshold"));
if (v.isValid())
prefs.pp_graphs.po2_threshold = v.toDouble();
@ -392,14 +392,15 @@ void MainWindow::readSettings()
prefs.mod_ppO2 = v.toDouble();
GET_BOOL(v, "ead", prefs.ead);
GET_BOOL(v, "redceiling", prefs.profile_red_ceiling);
GET_BOOL(v, "show_dc_reported_ceiling", prefs.profile_dc_ceiling);
GET_BOOL(v, "calcceiling", prefs.profile_calc_ceiling);
GET_BOOL(v, "calcceiling3m", prefs.calc_ceiling_3m_incr);
v = settings.value(QString("gflow"));
if (v.isValid())
prefs.gflow = v.toInt() / 100.0;
prefs.gflow = v.toInt();
v = settings.value(QString("gfhigh"));
if (v.isValid())
prefs.gfhigh = v.toInt() / 100.0;
prefs.gfhigh = v.toInt();
set_gf(prefs.gflow, prefs.gfhigh);
settings.endGroup();
@ -420,7 +421,9 @@ void MainWindow::readSettings()
#define SAVE_VALUE(name, field) \
if (prefs.field != default_prefs.field) \
settings.setValue(name, prefs.field)
settings.setValue(name, prefs.field); \
else \
settings.remove(name)