	Correct: Handle more tanks than gasmixes
When Suunto Vytecs are used in gauge mode they don't record gasmixes.
If a tank pressure sensor is present they nevertheless record the
pressures. This patch handles this situation by assuming the tanks
contain air (and warning the user about this).
[Dirk Hohndel: I had mistakenly pushed out an earlier version of this
               commit, so this fixes things up to the final version]
Reported-by: antonnorth@gmail.com
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
			
			
This commit is contained in:
		
							parent
							
								
									8a8315d6fe
								
							
						
					
					
						commit
						67de8f3a49
					
				
					 1 changed files with 2 additions and 2 deletions
				
			
		| 
						 | 
				
			
			@ -96,10 +96,10 @@ static int parse_gasmixes(device_data_t *devdata, struct dive *dive, dc_parser_t
 | 
			
		|||
	if (rc == DC_STATUS_SUCCESS) {
 | 
			
		||||
		if (ntanks && ntanks < ngases) {
 | 
			
		||||
			shown_warning = true;
 | 
			
		||||
			report_error("Warning: different number of gases (%d) and tanks (%d)", ngases, ntanks);
 | 
			
		||||
			report_error("Warning: different number of gases (%d) and cylinders (%d)", ngases, ntanks);
 | 
			
		||||
		} else if (ntanks > ngases) {
 | 
			
		||||
			shown_warning = true;
 | 
			
		||||
			report_error("Warning: smaller number of gases (%d) than tanks (%d). Assuming air.", ngases, ntanks);
 | 
			
		||||
			report_error("Warning: smaller number of gases (%d) than cylinders (%d). Assuming air.", ngases, ntanks);
 | 
			
		||||
		}
 | 
			
		||||
	}
 | 
			
		||||
#endif
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||