Update user manual for CCR and pSCR dive logs
Update the text pertaining to CCR and pSCR dive logs to include the changes with respect to: 1) Colour of CCR setpoint graph and pSCR OC-equivalen pO2 graph. 2) Display of bailout information on dive logs. 3) Preferences tab allowing setting pertaining to the above. This is the first of a few PRs with updates to the user manual relating to CCR and pSCR dives. Correct some typos. Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
							
								
								
									
										
											BIN
										
									
								
								Documentation/images/CCR_bailout.jpg
									
										
									
									
									
										Normal file
									
								
							
							
						
						| 
		 After Width: | Height: | Size: 42 KiB  | 
| 
		 Before Width: | Height: | Size: 4.6 KiB After Width: | Height: | Size: 4.3 KiB  | 
| 
		 Before Width: | Height: | Size: 19 KiB After Width: | Height: | Size: 15 KiB  | 
| 
		 Before Width: | Height: | Size: 14 KiB After Width: | Height: | Size: 12 KiB  | 
							
								
								
									
										
											BIN
										
									
								
								Documentation/images/DiveModeChange.jpg
									
										
									
									
									
										Normal file
									
								
							
							
						
						| 
		 After Width: | Height: | Size: 10 KiB  | 
| 
		 Before Width: | Height: | Size: 41 KiB After Width: | Height: | Size: 36 KiB  | 
							
								
								
									
										
											BIN
										
									
								
								Documentation/images/pSCR_profile_bailout.jpg
									
										
									
									
									
										Normal file
									
								
							
							
						
						| 
		 After Width: | Height: | Size: 52 KiB  | 
| 
						 | 
				
			
			@ -2033,14 +2033,46 @@ To log pSCR dives, no special procedures are required. Use the normal steps outl
 | 
			
		|||
  Define all the appropriate cylinders as described above
 | 
			
		||||
  and indicate the cylinder/gas changes as described above in the section on xref:S_MulticylinderDives[multicylinder dives].
 | 
			
		||||
 | 
			
		||||
If a pSCR _Dive Mode_ has been selected, the dive ceiling for that is adjusted for the oxygen
 | 
			
		||||
drop across the mouthpiece, which often requires longer decompression periods. Below is a dive profile
 | 
			
		||||
In pSCR diving, the inspired gas often has a pO~2~ below that of the fresh gas from cylinder. This is
 | 
			
		||||
because fresh gas is only supplied at a slow rate and the diver continuously uses oxygen from the loop for metabolism,
 | 
			
		||||
resulting in the so-called "pO~2~ drop over the mouthpiece". For pSCR dive profiles the dive ceiling is adjusted for this oxygen
 | 
			
		||||
drop, and often requires longer decompression periods. Below is a dive profile
 | 
			
		||||
of a pSCR dive using EAN36 as bottom gas and oxygen for decompression. Note that this dive lasted
 | 
			
		||||
over two hours.
 | 
			
		||||
 | 
			
		||||
image::images/pSCR_profile.jpg["FIGURE: pSCR profile",align="center"]
 | 
			
		||||
 | 
			
		||||
_Visualising the pO~2~ drop_: The difference between the pO~2~ of the fresh cylinder gas and the pO~2~
 | 
			
		||||
in the loop can be visualised in _Subsurface_ by opening the _Profile_
 | 
			
		||||
panel in the _File -> Preferences_ menu item and then providing suitable information in the section
 | 
			
		||||
labelled _pSCR options_. The _pSCR metabolic rate_ is your rate of oxygen metabolism in liters/min (commonly
 | 
			
		||||
between 0.5 and 2.5). The _Dilution ratio_ is the ratio indicating how much gas in the loop is replaced with
 | 
			
		||||
fresh gas, relative to the gas being breathed (common values are between 1:3 and 1:10). These values are also
 | 
			
		||||
used when planning pSCR dives. If the oxygen content of the loop is not recorded by an oxygen sensor, _Subsurface_
 | 
			
		||||
estimates the pO~2~ in the loop using the information supplied above. This pO~2~ is shown as the green line
 | 
			
		||||
representing the oxygen partial pressure in the dive profile. If the oxygen pressure in the loop is measured using
 | 
			
		||||
an oxygen sensor connected to a dive computer, this information is probably recorded by the dive computer and these
 | 
			
		||||
measured pO~2~ values are shown on the dive profile. In addition, the _Preferences_ panel allows one to activate
 | 
			
		||||
a checkbox labelled _Show equivalent OC pO~2~ with pSCR pO~2~_. This activates display of the pO~2~ in the
 | 
			
		||||
fresh gas from the cylinder (an orange line). The vertical distance between the orange graph and the green graph
 | 
			
		||||
indicates the "pO~2~ drop over the mouthpiece". Much of pSCR diving involves managing this pO~2~ difference.
 | 
			
		||||
 | 
			
		||||
[icon="images/DiveModeChange.jpg"]
 | 
			
		||||
[NOTE]
 | 
			
		||||
_pSCR and bailout_: Gases used in pSCR often yield very low pO~2~ values in shallow water. For this reason the diver
 | 
			
		||||
often completes the shallow sections of a dive using open circuit (OC) rather than the rebreather. In this case
 | 
			
		||||
parts of the dive are
 | 
			
		||||
performed OC, while the rest of the dive is performed on the pSCR loop. To indicate such changes in divemode,
 | 
			
		||||
right-click on the dive profile at the appropriate time. From the context menu, select _Change divemode_ and choose
 | 
			
		||||
the appropriate option (see image on left). Some dive computers record such changes in divemode as part of the dive log.
 | 
			
		||||
The appropriate icon is shown on the depth profile (see image below).
 | 
			
		||||
Below is a pSCR dive with the shallow
 | 
			
		||||
sections using OC. An OC divemode was entered right at the start, followed by
 | 
			
		||||
a change to pSCR at 18m. During the ascent, there was a bailout to OC at 14m. Note,
 | 
			
		||||
for the OC sections, the pO~2~ is identical to the OC-pO~2~ whereas for the pSCR section, the pO~2~ (green line)
 | 
			
		||||
differs from the OC-pO~2~ (orange line).
 | 
			
		||||
 | 
			
		||||
image::images/pSCR_profile_bailout.jpg["FIGURE: pSCR profile with bailout",align="center"]
 | 
			
		||||
 | 
			
		||||
[[S_CCR_dives]]
 | 
			
		||||
==== Closed circuit rebreather (CCR) dives
 | 
			
		||||
| 
						 | 
				
			
			@ -2116,7 +2148,7 @@ image::images/CCR_preferences_f20.jpg["FIGURE: CCR preferences panel",align="cen
 | 
			
		|||
 | 
			
		||||
Checking any of these boxes allows the display of additional oxygen-related
 | 
			
		||||
information whenever the pO~2~ toolbar button on the _Profile_ panel is activated.
 | 
			
		||||
The first checkbox allows the display of setpoint information. This is a red line
 | 
			
		||||
The first checkbox allows the display of setpoint information. This is an orange line
 | 
			
		||||
superimposed on the green oxygen partial pressure graph and allows a comparison of the
 | 
			
		||||
mean measured oxygen partial pressure and the setpoint values, as shown below.
 | 
			
		||||
 | 
			
		||||
| 
						 | 
				
			
			@ -2143,7 +2175,41 @@ _Events_: Several events are logged, e.g. switching the mouthpiece to open circu
 | 
			
		|||
These events are indicated by yellow triangles and, if you hover over a triangle,
 | 
			
		||||
a description of that event is given as the bottom line in the xref:S_InfoBox[Information Box].
 | 
			
		||||
 | 
			
		||||
_Cylinder pressures_: Some CCR dive computers like the Poseidon MkVI record the
 | 
			
		||||
_Bailout_: Bailout events during a CCR dive can be recorded in a _Subsurface_ divelog. Right-click
 | 
			
		||||
on the dive profile to generate a dive profile context menu. Select _Change divemode_ and choose
 | 
			
		||||
the appropriate bailout option (probably OC). An appropriate icon is shown on the depth profile (see
 | 
			
		||||
image below). In most CCR equipment it is also
 | 
			
		||||
possible to bailout to pSCR, especially in cases where the electronics died and the diluent supply
 | 
			
		||||
is limited. This can also be reflected in the dive log and Subsurface will calculate and graph the
 | 
			
		||||
appropriate pO~2~ values. The case during CCR training is more complex if the instructor prefers
 | 
			
		||||
a low setpoint such as 0.7 to be maintained during bailout. In this case the CCR equipment
 | 
			
		||||
maintains the low setpoint and overrides the OC or pSCR conditions. In such cases it is probably
 | 
			
		||||
more accurate not to record a bailout event in the dive log since _Subsurface_ will calculate pO~2~
 | 
			
		||||
values based on the erroneous assumption that there is no setpoint.
 | 
			
		||||
Below is a dive profile for a CCR dive with bailout at 57 minutes. In this profile
 | 
			
		||||
the green pO~2~ graph diverges from the setpoint value and reflects the pO~2~ in the OC diluent gas
 | 
			
		||||
(in this case air).
 | 
			
		||||
The pO~2~ in the loop (shown as a meandering graph for each oxygen sensor) is irrelevant because
 | 
			
		||||
the actual inspired gas comes directly from the diluent cylinder. In cases where bailout occurs using
 | 
			
		||||
a stage cylinder, indicate the bailout as well as the gas change event and _Subsurface_ will calculate
 | 
			
		||||
all the appropriate pO~2~ values. Some dive computers record bailout events as well as gas change
 | 
			
		||||
events: in this case the events are shown automatically in the dive log.
 | 
			
		||||
 | 
			
		||||
image::images/CCR_bailout.jpg["FIGURE: CCR bailout profileh",align="center"]
 | 
			
		||||
 | 
			
		||||
_Deco ceiling_: The deco ceiling calculated by Subsurface is not very accurate because the precise pressure of nitrogen
 | 
			
		||||
in the loop can usually not be determined from the dive log imported from the CCR equipment. Many CCR dive
 | 
			
		||||
computers, however, report an internally-calculated deco ceiling that is reported in the dive log,
 | 
			
		||||
reflecting a more accurate assessment. The display of this ceiling is activated
 | 
			
		||||
by clicking the appropriate button to the left of the dive profile:
 | 
			
		||||
 | 
			
		||||
image::images/icons/cceiling.jpg["DC ceiling icon"]
 | 
			
		||||
 | 
			
		||||
The default color of the computer-generated deco ceiling is white. This can be set to red
 | 
			
		||||
by checking the appropriate check box after selecting _File  ->  Preferences  ->  Profile_.
 | 
			
		||||
The profile above indicates the dive computer-generated deco ceiling in red.
 | 
			
		||||
 | 
			
		||||
_Cylinder pressures_: Some CCR dive computers like Poseidon record the
 | 
			
		||||
pressures of the oxygen and diluent cylinders. The pressures of these two cylinders
 | 
			
		||||
are shown as green lines overlapping the depth profile. In addition, start and
 | 
			
		||||
end pressures for both oxygen and diluent cylinders are shown in the _Equipment Tab_.
 | 
			
		||||
| 
						 | 
				
			
			@ -2157,22 +2223,8 @@ _Equipment-specific information_: Equipment-specific information gathered by
 | 
			
		|||
_Subsurface_ is shown in the xref:S_ExtraDataTab[Extra data tab]. This may include setup information
 | 
			
		||||
or metadata about the dive.
 | 
			
		||||
 | 
			
		||||
The deco ceiling calculated by Subsurface is not very accurate because the precise pressure of nitrogen
 | 
			
		||||
in the loop can usually not be determined from the dive log imported from the CCR equipment. Many CCR dive
 | 
			
		||||
computers, however, report an internally-calculated deco ceiling that is reported in the dive log,
 | 
			
		||||
reflecting a more accurate assessment. The display of this ceiling is activated
 | 
			
		||||
by clicking the appropriate button to the left of the dive profile:
 | 
			
		||||
 | 
			
		||||
image::images/icons/cceiling.jpg["DC ceiling icon"]
 | 
			
		||||
 | 
			
		||||
The default color of the computer-generated deco ceiling is white. This can be set to red
 | 
			
		||||
by checking the appropriate check box after selecting _File  ->  Preferences  ->  Profile_.
 | 
			
		||||
Below is a dive profile indicating the dive computer-generated deco ceiling:
 | 
			
		||||
 | 
			
		||||
image::images/CCR_dive_ceilingF22.jpg["FIGURE: CCR computer-generated deco ceiling",align="center"]
 | 
			
		||||
 | 
			
		||||
More equipment-specific information for downloading CCR dive logs for
 | 
			
		||||
Poseidon MkVI and APD equipment can be found in xref:_appendix_b_dive_computer_specific_information_for_importing_dive_information[Appendix B].
 | 
			
		||||
More equipment-specific procedures and information for downloading CCR dive logs for
 | 
			
		||||
Poseidon and APD equipment can be found in xref:_appendix_b_dive_computer_specific_information_for_importing_dive_information[Appendix B].
 | 
			
		||||
 | 
			
		||||
== Obtaining more information about dives entered into the logbook
 | 
			
		||||
 | 
			
		||||
| 
						 | 
				
			
			@ -3375,13 +3427,27 @@ image::images/Pref4_f23.jpg["FIGURE: Preferences Graph page",align="center"]
 | 
			
		|||
    during a particular dive. Setpoint changes during the dive can be added via the
 | 
			
		||||
    profile context menu.
 | 
			
		||||
 | 
			
		||||
*** _CCR: Show O~2~ sensor values when viewing pO~2~:_ Show the pO~2~
 | 
			
		||||
    values associated with each of the individual oxygen sensors of a CCR system.
 | 
			
		||||
    See the section on xref:S_CCR_dives[Closed Circuit Rebreather dives].
 | 
			
		||||
 | 
			
		||||
*** _CCR: Show setpoints when viewing pO~2~:_ With this checkbox activated, the pO~2~
 | 
			
		||||
    graph on the dive profile has an overlay in red which indicates the CCR setpoint
 | 
			
		||||
    values. See the section on xref:S_CCR_dives[Closed Circuit Rebreather dives].
 | 
			
		||||
 | 
			
		||||
*** _CCR: Show individual O~2~ sensor values when viewing pO~2~:_ Show the pO~2~
 | 
			
		||||
    values associated with each of the individual oxygen sensors of a CCR system.
 | 
			
		||||
    See the section on xref:S_CCR_dives[Closed Circuit Rebreather dives].
 | 
			
		||||
**  _pSCR options_. These preferences determine how passive semi-closed circuit (pSCR) dives
 | 
			
		||||
    are planned and how the pSCR deco ceiling is calculated:
 | 
			
		||||
 | 
			
		||||
*** _Metabolic rate:_ this is the
 | 
			
		||||
    volume of oxygen used by a diver during a minute. Set this value for pSCR dive planning
 | 
			
		||||
    and decompression calculations.
 | 
			
		||||
 | 
			
		||||
*** _pSCR ratio:_ The dilution ratio (or dump ratio) is the ratio of gas released to the
 | 
			
		||||
    environment to that of the gas recirculated to the diver. A 1:10 ratio is commonly used.
 | 
			
		||||
 | 
			
		||||
*** _Show equivalent OC with pSCR pO~2~_: The pO~2~ in the pSCR loop is usually lower than the
 | 
			
		||||
    pO~2~ of the fresh gas from the cylinder. Activating this checkbox allows the pO~2~ graph
 | 
			
		||||
    in the dive profile to also show the pO~2~ of the fresh gas entering the loop.
 | 
			
		||||
 | 
			
		||||
* *Ceiling display setup*. These settings mostly deal with nitrogen and helium management
 | 
			
		||||
   by determining how the decompression ceiling (ascent ceiling) is calculated and displayed:
 | 
			
		||||
| 
						 | 
				
			
			@ -3415,15 +3481,6 @@ image::images/Pref4_f23.jpg["FIGURE: Preferences Graph page",align="center"]
 | 
			
		|||
 | 
			
		||||
 *** link:http://www.rebreatherworld.com/general-and-new-to-rebreather-articles/5037-gradient-factors-for-dummies.html[Gradient factors for dummies, by Kevin Watts]
 | 
			
		||||
 | 
			
		||||
 **  _pSCR options_. These preferences determine how passive semi-closed circuit (pSCR) dives
 | 
			
		||||
    are planned and how the pSCR deco ceiling is calculated:
 | 
			
		||||
 | 
			
		||||
 *** _Metabolic rate:_ this is the
 | 
			
		||||
    volume of oxygen used by a diver during a minute. Set this value for pSCR dive planning
 | 
			
		||||
    and decompression calculations.
 | 
			
		||||
 | 
			
		||||
 *** _pSCR ratio:_ The dilution ratio (or dump ratio) is the ratio of gas released to the
 | 
			
		||||
    environment to that of the gas recirculated to the diver. A 1:10 ratio is commonly used.
 | 
			
		||||
 | 
			
		||||
* *Misc*
 | 
			
		||||
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||