mirror of
https://github.com/subsurface/subsurface.git
synced 2025-02-19 22:16:15 +00:00
Cylinders: access cylinders with get_cylinder()
Instead of accessing the cylinder table directly, use the get_cylinder() function. This gives less unwieldy expressions. But more importantly, the function does bound checking. This is crucial for now as the code hasn't be properly audited since the change to arbitrarily sized cylinder tables. Accesses of invalid cylinder indexes may lead to silent data-corruption that is sometimes not even noticed by valgrind. Returning NULL instead of an invalid pointer will make debugging much easier. Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This commit is contained in:
parent
52d8d89f73
commit
794066b236
30 changed files with 149 additions and 148 deletions
|
@ -1536,7 +1536,7 @@ void ProfileWidget2::contextMenuEvent(QContextMenuEvent *event)
|
|||
int newGasIdx = gasChangeIdx + 1;
|
||||
const struct plot_data &newGasEntry = plotInfo.entry[newGasIdx];
|
||||
qDebug() << "after gas change at " << newGasEntry->sec << ": sensor pressure" << newGasEntry->pressure[0] << "interpolated" << newGasEntry->pressure[1];
|
||||
if (get_plot_sensor_pressure(&plotInfo, gasChangeIdx) == 0 || displayed_dive.cylinders.cylinders[gasChangeEntry->sensor[0]].sample_start.mbar == 0) {
|
||||
if (get_plot_sensor_pressure(&plotInfo, gasChangeIdx) == 0 || get_cylinder(&displayed_dive, gasChangeEntry->sensor[0])->sample_start.mbar == 0) {
|
||||
// if we have no sensorpressure or if we have no pressure from samples we can assume that
|
||||
// we only have interpolated pressure (the pressure in the entry may be stored in the sensor
|
||||
// pressure field if this is the first or last entry for this tank... see details in gaspressures.c
|
||||
|
@ -1545,7 +1545,7 @@ void ProfileWidget2::contextMenuEvent(QContextMenuEvent *event)
|
|||
QAction *adjustOldPressure = m.addAction(tr("Adjust pressure of cyl. %1 (currently interpolated as %2)")
|
||||
.arg(gasChangeEntry->sensor[0] + 1).arg(get_pressure_string(pressure)));
|
||||
}
|
||||
if (get_plot_sensor_pressure(&plotInfo, newGasIdx) == 0 || displayed_dive.cylinders.cylinders[newGasEntry->sensor[0]].sample_start.mbar == 0) {
|
||||
if (get_plot_sensor_pressure(&plotInfo, newGasIdx) == 0 || get_cylinder(&displayed_dive, newGasEntry->sensor[0])->sample_start.mbar == 0) {
|
||||
// we only have interpolated press -- see commend above
|
||||
pressure_t pressure;
|
||||
pressure.mbar = get_plot_interpolated_pressure(&plotInfo, newGasIdx) ? : get_plot_sensor_pressure(&plotInfo, newGasIdx);
|
||||
|
@ -1882,7 +1882,7 @@ void ProfileWidget2::repositionDiveHandlers()
|
|||
QLineF line(p1, p2);
|
||||
QPointF pos = line.pointAt(0.5);
|
||||
gases[i]->setPos(pos);
|
||||
gases[i]->setText(get_gas_string(displayed_dive.cylinders.cylinders[datapoint.cylinderid].gasmix));
|
||||
gases[i]->setText(get_gas_string(get_cylinder(&displayed_dive, datapoint.cylinderid)->gasmix));
|
||||
gases[i]->setVisible(datapoint.entered &&
|
||||
(i == 0 || gases[i]->text() != gases[i-1]->text()));
|
||||
}
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue