mirror of
				https://github.com/subsurface/subsurface.git
				synced 2025-02-19 22:16:15 +00:00 
			
		
		
		
	User manual: Using CCR equipment with Subsurface.
This is a first stab at some text detailing the import and handling of CCR dives within Subsurface. Three figures added. Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>Kind regards, willem From da16229327331731794b356b8e8504a4cd160634 Mon Sep 17 00:00:00 2001 From: willem ferguson <willemferguson@zoology.up.ac.za> Date: Sun, 16 Nov 2014 15:50:44 +0200 Subject: [PATCH] Update user manual with CCR instructions This is a first stab at some text detailing the import and handling of CCR dives within Subsurface. Three figures added. Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
		
							parent
							
								
									d84f76ae14
								
							
						
					
					
						commit
						7967d2bec1
					
				
					 4 changed files with 104 additions and 1 deletions
				
			
		
							
								
								
									
										
											BIN
										
									
								
								Documentation/images/APD.jpg
									
										
									
									
									
										Normal file
									
								
							
							
						
						
									
										
											BIN
										
									
								
								Documentation/images/APD.jpg
									
										
									
									
									
										Normal file
									
								
							
										
											Binary file not shown.
										
									
								
							| After Width: | Height: | Size: 34 KiB | 
							
								
								
									
										
											BIN
										
									
								
								Documentation/images/APDComputer.jpg
									
										
									
									
									
										Normal file
									
								
							
							
						
						
									
										
											BIN
										
									
								
								Documentation/images/APDComputer.jpg
									
										
									
									
									
										Normal file
									
								
							
										
											Binary file not shown.
										
									
								
							| After Width: | Height: | Size: 8.5 KiB | 
							
								
								
									
										
											BIN
										
									
								
								Documentation/images/MkVI.jpeg
									
										
									
									
									
										Normal file
									
								
							
							
						
						
									
										
											BIN
										
									
								
								Documentation/images/MkVI.jpeg
									
										
									
									
									
										Normal file
									
								
							
										
											Binary file not shown.
										
									
								
							| After Width: | Height: | Size: 4.9 KiB | 
|  | @ -963,14 +963,69 @@ available, as in dialogue *B*, above. Currently these are: | |||
|  - XML-formatted dive logs (Divinglog 5.0, MacDive and several other dive log systems) | ||||
|  - UDDF-formatted dive logs (e.g. Kenozoooid) | ||||
|  - UDCF-formatted dive logs | ||||
|  - Poseidon CCR logs | ||||
|  - JDiveLog | ||||
|  - Suunto Dive Manager (DM3 and DM4) | ||||
|  - CSV (text-based and spreadsheet-based) dive logs. | ||||
|  - CSV (text-based and spreadsheet-based) dive logs, including APD CCR logs | ||||
| 
 | ||||
| Selecting the appropriate file in the file list of the dialogue opens | ||||
| the imported dive log in the _Subsurface_ *Dive List*. Some other formats, not | ||||
| accessible through the Import dialogue are also supported, as explained below. | ||||
| 
 | ||||
| ==== Importing dive logs from closed circuit rebreather (CCR) systems | ||||
| 
 | ||||
| [icon="images/APD.jpg"] | ||||
| [NOTE] | ||||
| Closed system rebreathers use avanced technology to recirculate | ||||
| gas that has been breathed while doing two things to maintain a | ||||
| breathable oxygen concentration: | ||||
| a) remove carbon dioxide from the gas that has been exhaled | ||||
| b) regulate the oxygen concentration to remain within safe diving limits. | ||||
| Currently, within _Subsurface_, the Poseidon MkVI Discovery is the best | ||||
| supported CCR dive computer. The CCR interface of _Subsurface_ is currently experimental | ||||
| and under active development. In contrast to a conventional open circuit | ||||
| dive computer, a CCR system computer does not allow the download of a log | ||||
| containg multiple dives. Rather, each dive is stored independently. This | ||||
| means that _Subsurface_ cannot download a dive log directly from a CCR | ||||
| dive computer, but that it imports CCR dive logs in the same way that it | ||||
| imports dive log data from other databases. | ||||
| 
 | ||||
| ===== Import a CCR dive | ||||
| 
 | ||||
| See the section dealing with xref:S_ImportingAlienDiveLogs[Importing dive information from other | ||||
| digital sources]. From the main menu of _Subsurface_, select _Import->Import | ||||
| log files_ to bring up the xref:Unified_import[universal import dialogue]. As | ||||
| explained in the previous section, the bottom right | ||||
| hand of the import dialogue contains a dropdown list of appropriate devices | ||||
| that currently includes an option for MkVI files. Having selected the appropriate CCR format and | ||||
| the directory where the original dive logs have been stored from the CCR dive | ||||
| computer, one can select a particular dive log file (in the case of the MkVI | ||||
| it is a file with a .txt extension). After selecting the appropriate dive log, | ||||
| activate the _Open_ button at the bottom right hand of the universal import dialogue. | ||||
| 
 | ||||
| ===== Displayed information for a  dive | ||||
| 
 | ||||
| _Partial pressures of gases_: The graph of oxygen partial pressure shows the | ||||
| information from the oxygen sensors of the CCR equipment. In the case of the | ||||
| Poseidon MKVI, the mean value of the two oxygen sensors are shown. In the case | ||||
| of the APD equipment, the mean of the three oxygen sensors are shown. If one | ||||
| sensor shows a very different oxygen PO2 reading compared to the others, the | ||||
| divergent sensor is ingnored. For CCR dives the graph for oxygen partial pressure | ||||
| should be fairly flat, reflecting the setpoint settings during the dive. | ||||
| Partial pressures for nitrogen (and helium, | ||||
| if applicable) are shown in the usual way as for other dives. | ||||
| 
 | ||||
| _Cylinder pressures_: CCR dive computers like the Poseidon MkVI record the | ||||
| pressures of the oxygen and diluent cylinders. The pressure of the oxygen cylinder | ||||
| is shown on the dive profile. In addition, start and end pressures for both oxygen | ||||
| and diluent cylinders are shown in the _Equipment Tab_. | ||||
| 
 | ||||
| _Equipment-specific information_: Equipment-specific information gathered by | ||||
| _Subsurface_ is shown in the _Extra data_ tab. This may include setup information | ||||
| or metadata about the dive. | ||||
| 
 | ||||
| More equipment-specific information for downloading CCR dive logs can be found in xref:S_PoseidonMkVI[Appendix B]. | ||||
| 
 | ||||
| ==== Importing from Mares Dive Organiser V2.1 | ||||
| 
 | ||||
| Since Mares utilise proprietary Windows software not compatible with | ||||
|  | @ -2901,6 +2956,54 @@ this, but it is reported to be solved sometimes by one of these steps: | |||
|  * switch to different Bluetooth drivers for the same hardware | ||||
|  * switch off WiFi while using Bluetooth | ||||
| 
 | ||||
| [[S_PoseidonMkVI]] | ||||
| === Importing dive logs from the Poseidon MkVI Discovery | ||||
| 
 | ||||
| [icon="images/MkVI.jpeg"] | ||||
| [NOTE] | ||||
| Download of dive logs from the MkVI is performed using a custom communications | ||||
| adapter and the _Poseidon PC Configuration Software_, obtained when purchasing | ||||
| the MKVI equipment. The latter is a Windows application allowing configuration | ||||
| of equipment and storage of dive logs. Communication between dive computer and | ||||
| desktop computer utilises the IrDA infra-red protocol. Only data for one dive | ||||
| can be downloaded at a time, comprising three files: | ||||
| 
 | ||||
| - Setup configuration for the dive and key dive parameters (file with a .txt | ||||
| extension) | ||||
| - Dive log details (file with a .csv extension) | ||||
| - Redbook format dive log (file with .cvsr extension). This is a compressed | ||||
| version of the dive log using a propriatary format. | ||||
| 
 | ||||
| _Subsurface_ accesses the .txt and the .csv files to obtain dive log information. | ||||
| 
 | ||||
| 
 | ||||
| === Importing dive logs from the APD Inspiration CCR | ||||
| 
 | ||||
| [icon="images/APDComputer.jpg"] | ||||
| [NOTE] | ||||
| The dive logs of an APD Inspiration or similar CCR dive computer are downloaded using | ||||
| a communications adapter and _AP Communicator_, obtained when | ||||
| purchasing the equipment. The dive logs can be viewed using the _AP Log Viewer_, | ||||
| within Windows or Mac/OS. However, APD logs can be viewed and managed from within | ||||
| _Subsurface_ (together with dives using many other types of dive computer). The | ||||
| APD inspiration dive logs are imported into _Subsurface_ as follows: | ||||
| 
 | ||||
| - Open a dive within the _AP Log Viewer_. | ||||
| - Select the tab at the top of the screen, entitled "_Data_". | ||||
| - If the raw dive log data show on the screen, click on "_Copy to Clipboard_". | ||||
| - Open a text editor, e.g. Notepad (Windows), TextWrangler (Mac). | ||||
| - Copy the contents of the clipboard into the text editor and save the text file | ||||
| with a filename extension of .CSV | ||||
| - Within _Subsurface_, select _Import->Import log files_ to open the xref:Unified_import[universal import dialogue]. | ||||
| - In the dropdown list towards the bottom right of the dialogue, select "_CSV files_". | ||||
| - On the list of file names select the .CSV file that has been created above. An import | ||||
| dialogue opens. | ||||
| - In the dropdown list on the middle right labeled '_Pre-configured imports_", | ||||
| select _APD Log Viewer_. | ||||
| - Ensure the other settings for the ADP dive log are appropriate, then select _OK_. | ||||
| 
 | ||||
| The APD dive log will appear within _Subsurface_. | ||||
| 
 | ||||
| 
 | ||||
| == APPENDIX C: Exporting Dive log information from external dive log software. | ||||
| 
 | ||||
|  |  | |||
		Loading…
	
	Add table
		Add a link
		
	
		Reference in a new issue