Minimum gas calculation - Calculations and UI parameters

Add minimum gas calculation to planner output.
Add the two UI parameters prefs.sacfactor and prefs.problemsolvingtime.
Connect UI signals and slots for recalculation of diveplan.

Disable minimum gas calculation if there was already a warning before.
If minimum gas result is larger then cylinder start pressure give warning message instead of result.

Add line break before pO2 warnings but only if warnings exist.

Signed-off-by: Joachim Ritter <jritter@bitsenke.de>
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
This commit is contained in:
Stefan Fuchs 2017-02-11 20:24:18 +01:00 committed by Dirk Hohndel
parent b8e044dee3
commit 7f8c3592ce
10 changed files with 240 additions and 45 deletions

View file

@ -401,6 +401,20 @@ void DivePlannerPointsModel::setDecoSac(double sac)
emitDataChanged();
}
void DivePlannerPointsModel::setSacFactor(double factor)
{
auto planner = SettingsObjectWrapper::instance()->planner_settings;
planner->setSacFactor((int) round(factor * 100));
emitDataChanged();
}
void DivePlannerPointsModel::setProblemSolvingTime(int minutes)
{
auto planner = SettingsObjectWrapper::instance()->planner_settings;
planner->setProblemSolvingTime(minutes);
emitDataChanged();
}
void DivePlannerPointsModel::setGFHigh(const int gfhigh)
{
tempGFHigh = gfhigh;