Add some gas mix validation to the planner

A few basic rules for gas validation:
	We can't have <0%, or >100% of either O2 or He
	O2 + He must not be >100%
	Switch depth can't be <0%

This places limits on user-input values

Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
Rick Walsh 2016-05-22 11:00:22 +10:00 committed by Dirk Hohndel
parent 47a2e8b1d9
commit 8acbeed555
2 changed files with 15 additions and 0 deletions

View file

@ -249,6 +249,9 @@ bool CylindersModel::setData(const QModelIndex &index, const QVariant &value, in
case O2:
if (CHANGED()) {
cyl->gasmix.o2 = string_to_fraction(vString.toUtf8().data());
// fO2 + fHe must not be greater than 1
if (((cyl->gasmix.o2.permille == 0) ? O2_IN_AIR : cyl->gasmix.o2.permille) + cyl->gasmix.he.permille > 1000)
cyl->gasmix.he.permille = 1000 - ((cyl->gasmix.o2.permille == 0) ? O2_IN_AIR : cyl->gasmix.o2.permille);
pressure_t modpO2;
if (displayed_dive.dc.divemode == PSCR)
modpO2.mbar = prefs.decopo2 + (1000 - get_o2(&cyl->gasmix)) * SURFACE_PRESSURE *
@ -262,6 +265,9 @@ bool CylindersModel::setData(const QModelIndex &index, const QVariant &value, in
case HE:
if (CHANGED()) {
cyl->gasmix.he = string_to_fraction(vString.toUtf8().data());
// fO2 + fHe must not be greater than 1
if (((cyl->gasmix.o2.permille == 0) ? O2_IN_AIR : cyl->gasmix.o2.permille) + cyl->gasmix.he.permille > 1000)
cyl->gasmix.o2.permille = 1000 - cyl->gasmix.he.permille;
changed = true;
}
break;