mirror of
https://github.com/subsurface/subsurface.git
synced 2024-11-30 22:20:21 +00:00
Do not zero setpoint value when duplicate
We cannot zero setpoint value upon import if the current and previous values are zero. This is because on setpoint context a value of 0 means open circuit. Signed-off-by: Miika Turkia <miika.turkia@gmail.com> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
parent
1f1bb71d78
commit
8b6d49092b
1 changed files with 1 additions and 10 deletions
11
dive.c
11
dive.c
|
@ -1092,7 +1092,7 @@ static void fixup_dive_dc(struct dive *dive, struct divecomputer *dc)
|
|||
int maxdepth = dc->maxdepth.mm;
|
||||
int mintemp = 0;
|
||||
int lastdepth = 0;
|
||||
int lasto2val[3] = { 0, 0, 0 }, lasto2setpoint = 0;
|
||||
int lasto2val[3] = { 0, 0, 0 };
|
||||
int lasttemp = 0, lastpressure = 0, lastdiluentpressure = 0;
|
||||
int pressure_delta[MAX_CYLINDERS] = { INT_MAX, };
|
||||
|
||||
|
@ -1166,15 +1166,6 @@ static void fixup_dive_dc(struct dive *dive, struct divecomputer *dc)
|
|||
}
|
||||
}
|
||||
|
||||
// If there are consecutive identical CCR O2 setpoint readings, throw away the redundant ones.
|
||||
o2val = sample->setpoint.mbar;
|
||||
if (o2val) {
|
||||
if (lasto2setpoint == o2val)
|
||||
sample->setpoint.mbar = 0;
|
||||
else
|
||||
lasto2setpoint = o2val;
|
||||
}
|
||||
|
||||
update_min_max_temperatures(dive, sample->temperature);
|
||||
|
||||
depthtime += (time - lasttime) * (lastdepth + depth) / 2;
|
||||
|
|
Loading…
Reference in a new issue