mirror of
https://github.com/subsurface/subsurface.git
synced 2025-01-31 18:33:23 +00:00
Handle more tanks than gasmixes
When Suunto Vytecs are used in gauge mode they don't record gasmixes. If a tank pressure sensor is present they nevertheless record the pressures. This patch handles this situation by assuming the tanks contain air (and warning the user about this). Reported-by: antonnorth@gmail.com Signed-off-by: Robert C. Helling <helling@atdotde.de> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
parent
bc8c9f4c6f
commit
99595542ec
1 changed files with 35 additions and 27 deletions
|
@ -94,45 +94,53 @@ static int parse_gasmixes(device_data_t *devdata, struct dive *dive, dc_parser_t
|
|||
unsigned int ntanks = 0;
|
||||
rc = dc_parser_get_field(parser, DC_FIELD_TANK_COUNT, 0, &ntanks);
|
||||
if (rc == DC_STATUS_SUCCESS) {
|
||||
if (ntanks && ntanks != ngases) {
|
||||
if (ntanks && ntanks < ngases) {
|
||||
shown_warning = true;
|
||||
report_error("different number of gases (%d) and tanks (%d)", ngases, ntanks);
|
||||
report_error("Warning: different number of gases (%d) and tanks (%d)", ngases, ntanks);
|
||||
} else if (ntanks > ngases) {
|
||||
shown_warning = true;
|
||||
report_error("Warning: smaller number of gases (%d) than tanks (%d). Assuming air.", ngases, ntanks);
|
||||
}
|
||||
}
|
||||
#endif
|
||||
bool no_volume = true;
|
||||
|
||||
for (i = 0; i < ngases; i++) {
|
||||
dc_gasmix_t gasmix = { 0 };
|
||||
int o2, he;
|
||||
bool no_volume = true;
|
||||
for (i = 0; i < ngases || i < ntanks; i++) {
|
||||
if (i < ngases) {
|
||||
dc_gasmix_t gasmix = { 0 };
|
||||
int o2, he;
|
||||
|
||||
rc = dc_parser_get_field(parser, DC_FIELD_GASMIX, i, &gasmix);
|
||||
if (rc != DC_STATUS_SUCCESS && rc != DC_STATUS_UNSUPPORTED)
|
||||
return rc;
|
||||
rc = dc_parser_get_field(parser, DC_FIELD_GASMIX, i, &gasmix);
|
||||
if (rc != DC_STATUS_SUCCESS && rc != DC_STATUS_UNSUPPORTED)
|
||||
return rc;
|
||||
|
||||
if (i >= MAX_CYLINDERS)
|
||||
continue;
|
||||
if (i >= MAX_CYLINDERS)
|
||||
continue;
|
||||
|
||||
o2 = rint(gasmix.oxygen * 1000);
|
||||
he = rint(gasmix.helium * 1000);
|
||||
o2 = rint(gasmix.oxygen * 1000);
|
||||
he = rint(gasmix.helium * 1000);
|
||||
|
||||
/* Ignore bogus data - libdivecomputer does some crazy stuff */
|
||||
if (o2 + he <= O2_IN_AIR || o2 > 1000) {
|
||||
if (!shown_warning) {
|
||||
shown_warning = true;
|
||||
report_error("unlikely dive gas data from libdivecomputer: o2 = %d he = %d", o2, he);
|
||||
/* Ignore bogus data - libdivecomputer does some crazy stuff */
|
||||
if (o2 + he <= O2_IN_AIR || o2 > 1000) {
|
||||
if (!shown_warning) {
|
||||
shown_warning = true;
|
||||
report_error("unlikely dive gas data from libdivecomputer: o2 = %d he = %d", o2, he);
|
||||
}
|
||||
o2 = 0;
|
||||
}
|
||||
o2 = 0;
|
||||
}
|
||||
if (he < 0 || o2 + he > 1000) {
|
||||
if (!shown_warning) {
|
||||
shown_warning = true;
|
||||
report_error("unlikely dive gas data from libdivecomputer: o2 = %d he = %d", o2, he);
|
||||
if (he < 0 || o2 + he > 1000) {
|
||||
if (!shown_warning) {
|
||||
shown_warning = true;
|
||||
report_error("unlikely dive gas data from libdivecomputer: o2 = %d he = %d", o2, he);
|
||||
}
|
||||
he = 0;
|
||||
}
|
||||
he = 0;
|
||||
dive->cylinder[i].gasmix.o2.permille = o2;
|
||||
dive->cylinder[i].gasmix.he.permille = he;
|
||||
} else {
|
||||
dive->cylinder[i].gasmix.o2.permille = 0;
|
||||
dive->cylinder[i].gasmix.he.permille = 0;
|
||||
}
|
||||
dive->cylinder[i].gasmix.o2.permille = o2;
|
||||
dive->cylinder[i].gasmix.he.permille = he;
|
||||
|
||||
#if DC_VERSION_CHECK(0, 5, 0) && defined(DC_GASMIX_UNKNOWN)
|
||||
if (i < ntanks) {
|
||||
|
|
Loading…