Use displayed_dc instead of current_dc
current_dc is a macro that determines the dive computer based on the current dive number. When the planner is started from an emtpy dive list, the dive number ends up being -1 and that doesn't produce a valid dive computer. Use the divecomputer of the displayed_dive instead. This is done via a macro that can also be used in two other places. Without this patch, the planner crashed when called on an empty dive list. Signed-off-by: Robert C. Helling <helling@atdotde.de>
This commit is contained in:
parent
a9b692f0c3
commit
a422957cd6
4 changed files with 3 additions and 3 deletions
|
@ -428,7 +428,7 @@ void DivePercentageItem::paint(QPainter *painter, const QStyleOptionGraphicsItem
|
|||
struct gasmix *gasmix = NULL;
|
||||
struct event *ev = NULL;
|
||||
int sec = dataModel->index(i, DivePlotDataModel::TIME).data().toInt();
|
||||
gasmix = get_gasmix(&displayed_dive, current_dc, sec, &ev, gasmix);
|
||||
gasmix = get_gasmix(&displayed_dive, displayed_dc, sec, &ev, gasmix);
|
||||
int inert = 1000 - get_o2(gasmix);
|
||||
mypen.setBrush(QBrush(ColorScale(value, inert)));
|
||||
painter->setPen(mypen);
|
||||
|
|