Get the cylinder use data from libdivecomputer if provided
This uses the extended tank type information to fill in the cylinder use (OC gas, CC Diluent or CC O2) from libdivecomputer when available. Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
parent
7c8073e7ea
commit
b2f2a865eb
1 changed files with 24 additions and 5 deletions
|
@ -16,6 +16,18 @@
|
|||
#include <libdivecomputer/version.h>
|
||||
#include "libdivecomputer.h"
|
||||
|
||||
//
|
||||
// If we have an old libdivecomputer, it doesn't
|
||||
// have the new DC_TANKINFO bits, but just volume
|
||||
// type information.
|
||||
//
|
||||
#ifndef DC_TANKINFO_METRIC
|
||||
#define DC_TANKINFO_METRIC DC_TANKVOLUME_METRIC
|
||||
#define DC_TANKINFO_IMPERIAL DC_TANKVOLUME_IMPERIAL
|
||||
#define DC_TANKINFO_CC_O2 0
|
||||
#define DC_TANKINFO_CC_DILUENT 0
|
||||
#endif
|
||||
|
||||
/* Christ. Libdivecomputer has the worst configuration system ever. */
|
||||
#ifdef HW_FROG_H
|
||||
#define NOT_FROG , 0
|
||||
|
@ -127,9 +139,18 @@ static int parse_gasmixes(device_data_t *devdata, struct dive *dive, dc_parser_t
|
|||
if (i < ntanks) {
|
||||
rc = dc_parser_get_field(parser, DC_FIELD_TANK, i, &tank);
|
||||
if (rc == DC_STATUS_SUCCESS) {
|
||||
if (tank.type == DC_TANKVOLUME_IMPERIAL) {
|
||||
dive->cylinder[i].type.size.mliter = rint(tank.volume * 1000);
|
||||
dive->cylinder[i].type.workingpressure.mbar = rint(tank.workpressure * 1000);
|
||||
cylinder_t *cyl = dive->cylinder + i;
|
||||
|
||||
cyl->type.size.mliter = rint(tank.volume * 1000);
|
||||
cyl->type.workingpressure.mbar = rint(tank.workpressure * 1000);
|
||||
|
||||
cyl->cylinder_use = OC_GAS;
|
||||
if (tank.type & DC_TANKINFO_CC_O2)
|
||||
cyl->cylinder_use = OXYGEN;
|
||||
if (tank.type & DC_TANKINFO_CC_DILUENT)
|
||||
cyl->cylinder_use = DILUENT;
|
||||
|
||||
if (tank.type & DC_TANKINFO_IMPERIAL) {
|
||||
if (same_string(devdata->model, "Suunto EON Steel")) {
|
||||
/* Suunto EON Steele gets this wrong. Badly.
|
||||
* but on the plus side it only supports a few imperial sizes,
|
||||
|
@ -163,8 +184,6 @@ static int parse_gasmixes(device_data_t *devdata, struct dive *dive, dc_parser_t
|
|||
dive->cylinder[i].type.size.mliter = cuft_to_l(rounded_size) * 1000 /
|
||||
mbar_to_atm(dive->cylinder[i].type.workingpressure.mbar);
|
||||
}
|
||||
} else if (tank.type == DC_TANKVOLUME_METRIC) {
|
||||
dive->cylinder[i].type.size.mliter = rint(tank.volume * 1000);
|
||||
}
|
||||
if (tank.gasmix != i) { // we don't handle this, yet
|
||||
shown_warning = true;
|
||||
|
|
Loading…