From c32c28d40b627fa08051697f44a829c7f19854d0 Mon Sep 17 00:00:00 2001 From: Rodrigo Severo Date: Wed, 8 Jan 2014 12:51:35 -0200 Subject: [PATCH] Interpolated pressure should always be set Interpolated pressure should always be set, even it we didn't calculate a new one. In this case we should just use the last one. Signed-off-by:Rodrigo Severo Signed-off-by: Dirk Hohndel --- profile.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/profile.c b/profile.c index 81c002966..637c89494 100644 --- a/profile.c +++ b/profile.c @@ -620,15 +620,15 @@ static void fill_missing_tank_pressures(struct dive *dive, struct plot_info *pi, #ifdef DEBUG_PR_INTERPOLATE dump_pr_interpolate(i, interpolate); #endif - /* if this segment had pressure time, set the interpolated pressure */ + /* if this segment has pressure time, calculate a new interpolated pressure */ if (interpolate.pressure_time) { /* Overall pressure change over total pressure-time for this segment*/ magic = (interpolate.end - interpolate.start) / (double) interpolate.pressure_time; /* Use that overall pressure change to update the current pressure */ cur_pr[cyl] = interpolate.start + magic * interpolate.acc_pressure_time + 0.5; - INTERPOLATED_PRESSURE(entry) = cur_pr[cyl]; } + INTERPOLATED_PRESSURE(entry) = cur_pr[cyl]; } }