Import: Fix the Handling of ppO2 Sensor IDs.
Instead of assigning sensor ids in the order that values are reported, actually use the sensor ids reported by libdivecomputer. This will fix the problem that for some dive computers (e.g. Shearwater) the dive computer calculated ppO2 is currently reported first, thus pushing out all actual sensor values. A new fixed id (7) outside of the range of currently supported sensor IDs is used for these dive computer calculated values. Signed-off-by: Michael Keller <github@ike.ch>
This commit is contained in:
parent
9ec1190a30
commit
c685f3d6a1
8 changed files with 38 additions and 17 deletions
|
@ -379,7 +379,6 @@ static void handle_gasmix(struct divecomputer *dc, const struct sample &sample,
|
|||
void
|
||||
sample_cb(dc_sample_type_t type, const dc_sample_value_t *pvalue, void *userdata)
|
||||
{
|
||||
static unsigned int nsensor = 0;
|
||||
struct divecomputer *dc = (divecomputer *)userdata;
|
||||
dc_sample_value_t value = *pvalue;
|
||||
|
||||
|
@ -388,8 +387,6 @@ sample_cb(dc_sample_type_t type, const dc_sample_value_t *pvalue, void *userdata
|
|||
* Other types fill in an existing sample.
|
||||
*/
|
||||
if (type == DC_SAMPLE_TIME) {
|
||||
nsensor = 0;
|
||||
|
||||
// Create a new sample.
|
||||
// Mark depth as negative
|
||||
struct sample *sample = prepare_sample(dc);
|
||||
|
@ -456,16 +453,23 @@ sample_cb(dc_sample_type_t type, const dc_sample_value_t *pvalue, void *userdata
|
|||
/* for us a setpoint means constant pO2 from here */
|
||||
sample.setpoint.mbar = po2 = lrint(value.setpoint * 1000);
|
||||
break;
|
||||
case DC_SAMPLE_PPO2:
|
||||
if (nsensor < MAX_O2_SENSORS)
|
||||
sample.o2sensor[nsensor].mbar = lrint(value.ppo2.value * 1000);
|
||||
else
|
||||
report_error("%d is more o2 sensors than we can handle", nsensor);
|
||||
nsensor++;
|
||||
// Set the amount of detected o2 sensors
|
||||
if (nsensor > dc->no_o2sensors)
|
||||
dc->no_o2sensors = nsensor;
|
||||
case DC_SAMPLE_PPO2: {
|
||||
unsigned int sensor_id = value.ppo2.sensor;
|
||||
if (sensor_id == DC_SENSOR_NONE) {
|
||||
sample.o2sensor[DC_REPORTED_PPO2].mbar = lrint(value.ppo2.value * 1000);
|
||||
} else if (sensor_id >= MAX_O2_SENSORS) {
|
||||
report_error("%d is more o2 sensors than we can handle", sensor_id + 1);
|
||||
|
||||
break;
|
||||
} else {
|
||||
sample.o2sensor[sensor_id].mbar = lrint(value.ppo2.value * 1000);
|
||||
|
||||
// Set the amount of detected o2 sensors
|
||||
if (sensor_id + 1 > dc->no_o2sensors)
|
||||
dc->no_o2sensors = sensor_id + 1;
|
||||
}
|
||||
break;
|
||||
}
|
||||
case DC_SAMPLE_CNS:
|
||||
sample.cns = cns = lrint(value.cns * 100);
|
||||
break;
|
||||
|
|