Allow for more O2 sensors

The Divesoft Liberty has four O2 sensors. So far, we had a hard coded
limit of three sensors and crashed with a failed assert when we
encoutered more than three. This allows for up to
MAX_O2_SENSORS which is currently 6. The voting logic is adapted
accordingly: We sort the values and we keep deleting the values that
differ more than 20% by value from the closest. This follows what
Shearwater implements on their computers.

In some of the import/export functions the value is still hard
coded to 6 thanks to explicit field names.

Signed-off-by: Robert C. Helling <helling@lmu.de>
This commit is contained in:
Robert C. Helling 2024-01-21 00:35:44 +01:00 committed by Robert C. Helling
parent e00e1bb9f7
commit e794efaba6
13 changed files with 31329 additions and 31257 deletions

File diff suppressed because it is too large Load diff