CCR code: Change to sample structure

1) All the variables in the sample structures are strongly typed
2) Two additional types were declared in units.h:
     o2pressure_t
     bearing_t
3) The following variables were added:
     diluentpressure
     o2setpoint
     o2sensor[3]
4) Changes to a number of files were made to chanf
     sample->po2 to sample->po2.mbar
     bearing to bearring.degrees

Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
Willem Ferguson 2014-06-03 19:21:41 +02:00 committed by Dirk Hohndel
parent 1fec6453a2
commit eaf6d56487
11 changed files with 64 additions and 51 deletions

22
units.h
View file

@ -59,22 +59,32 @@ typedef int64_t timestamp_t;
typedef struct
{
int seconds;
uint32_t seconds; // durations up to 68 yrs
} duration_t;
typedef struct
{
int mm;
} depth_t;
int32_t mm;
} depth_t; // depth to 2000 km
typedef struct
{
int mbar;
int32_t mbar; // pressure up to 2000 bar
} pressure_t;
typedef struct
{
int mkelvin;
uint16_t mbar;
} o2pressure_t; // pressure up to 65 bar
typedef struct
{
int16_t degrees;
} bearing_t; // compass bearing
typedef struct
{
int32_t mkelvin; // up to 1750 degrees K
} temperature_t;
typedef struct
@ -242,4 +252,4 @@ struct units {
}
#endif
#endif
#endif