mirror of
https://github.com/subsurface/subsurface.git
synced 2025-02-19 22:16:15 +00:00
Fix invalid bailout gas choice when planning a CCR dive.
Fixes a bug reported in https://groups.google.com/g/subsurface-divelog/c/8N3cTz2Zv5E: When planning a CCR dive with OC bailout, the diluent gas may be chosen as the first OC bailout gas, despite being set up with a use type of 'diluent', and likely not being available for open circuit breathing. `best_first_ascend_cylinder` is now initialised to an invalid value (instead of the first cylinder, which may or may not be a diluent cylinder), and its subsequent use is guarded by a validity check. Signed-off-by: Michael Keller <github@ike.ch>
This commit is contained in:
parent
eb5d4f2a15
commit
ec0c6833a0
4 changed files with 91 additions and 9 deletions
|
@ -372,6 +372,39 @@ void setupPlanSeveralGases(struct diveplan *dp)
|
|||
plan_add_segment(dp, 5 * 60, 10000, 0, 0, true, OC);
|
||||
}
|
||||
|
||||
void setupPlanCcr(struct diveplan *dp)
|
||||
{
|
||||
dp->salinity = 10300;
|
||||
dp->surface_pressure = 1013;
|
||||
dp->gflow = 50;
|
||||
dp->gfhigh = 70;
|
||||
dp->bottomsac = prefs.bottomsac;
|
||||
dp->decosac = prefs.decosac;
|
||||
|
||||
pressure_t po2 = {1600};
|
||||
struct gasmix diluent = {{200}, {210}};
|
||||
struct gasmix ean53 = {{530}, {0}};
|
||||
struct gasmix tx19_33 = {{190}, {330}};
|
||||
cylinder_t *cyl0 = get_or_create_cylinder(&displayed_dive, 0);
|
||||
cylinder_t *cyl1 = get_or_create_cylinder(&displayed_dive, 1);
|
||||
cylinder_t *cyl2 = get_or_create_cylinder(&displayed_dive, 2);
|
||||
cyl0->gasmix = diluent;
|
||||
cyl0->depth = gas_mod(diluent, po2, &displayed_dive, M_OR_FT(3, 10));
|
||||
cyl0->type.size.mliter = 3000;
|
||||
cyl0->type.workingpressure.mbar = 200000;
|
||||
cyl0->cylinder_use = DILUENT;
|
||||
cyl1->gasmix = ean53;
|
||||
cyl1->depth = gas_mod(ean53, po2, &displayed_dive, M_OR_FT(3, 10));
|
||||
cyl2->gasmix = tx19_33;
|
||||
cyl2->depth = gas_mod(tx19_33, po2, &displayed_dive, M_OR_FT(3, 10));
|
||||
reset_cylinders(&displayed_dive, true);
|
||||
free_dps(dp);
|
||||
|
||||
plan_add_segment(dp, 0, cyl1->depth.mm, 1, 0, false, OC);
|
||||
plan_add_segment(dp, 0, cyl2->depth.mm, 2, 0, false, OC);
|
||||
plan_add_segment(dp, 20 * 60, M_OR_FT(60, 197), 0, 1300, true, CCR);
|
||||
}
|
||||
|
||||
/* We compare the calculated runtimes against two values:
|
||||
* - Known runtime calculated by Subsurface previously (to detect if anything has changed)
|
||||
* - Benchmark runtime (we should be close, but not always exactly the same)
|
||||
|
@ -885,4 +918,50 @@ void TestPlan::testVpmbMetricRepeat()
|
|||
QCOMPARE(finalDiveRunTimeSeconds, firstDiveRunTimeSeconds);
|
||||
}
|
||||
|
||||
|
||||
// Test that the correct gases are selected during a CCR dive with bailout ascent
|
||||
// Includes a regression test for https://groups.google.com/g/subsurface-divelog/c/8N3cTz2Zv5E
|
||||
|
||||
void TestPlan::testCcrBailoutGasSelection()
|
||||
{
|
||||
struct deco_state *cache = NULL;
|
||||
|
||||
setupPrefs();
|
||||
prefs.unit_system = METRIC;
|
||||
prefs.units.length = units::METERS;
|
||||
prefs.planner_deco_mode = BUEHLMANN;
|
||||
displayed_dive.dc.divemode = CCR;
|
||||
prefs.dobailout = true;
|
||||
|
||||
struct diveplan testPlan = {};
|
||||
setupPlanCcr(&testPlan);
|
||||
|
||||
plan(&test_deco_state, &testPlan, &displayed_dive, 60, stoptable, &cache, true, false);
|
||||
|
||||
#if DEBUG
|
||||
free(displayed_dive.notes);
|
||||
displayed_dive.notes = NULL;
|
||||
save_dive(stdout, &displayed_dive, false);
|
||||
#endif
|
||||
|
||||
// check diluent used
|
||||
cylinder_t *cylinder = get_cylinder(&displayed_dive, get_cylinderid_at_time(&displayed_dive, &displayed_dive.dc, { 20 * 60 - 1 }));
|
||||
QCOMPARE(cylinder->cylinder_use, DILUENT);
|
||||
QCOMPARE(get_o2(cylinder->gasmix), 200);
|
||||
|
||||
// check deep bailout used
|
||||
cylinder = get_cylinder(&displayed_dive, get_cylinderid_at_time(&displayed_dive, &displayed_dive.dc, { 20 * 60 + 1 }));
|
||||
QCOMPARE(cylinder->cylinder_use, OC_GAS);
|
||||
QCOMPARE(get_o2(cylinder->gasmix), 190);
|
||||
|
||||
// check shallow bailout used
|
||||
cylinder = get_cylinder(&displayed_dive, get_cylinderid_at_time(&displayed_dive, &displayed_dive.dc, { 30 * 60 }));
|
||||
QCOMPARE(cylinder->cylinder_use, OC_GAS);
|
||||
QCOMPARE(get_o2(cylinder->gasmix), 530);
|
||||
|
||||
// check expected run time of 51 minutes
|
||||
QVERIFY(compareDecoTime(displayed_dive.dc.duration.seconds, 51 * 60, 51 * 60));
|
||||
|
||||
}
|
||||
|
||||
QTEST_GUILESS_MAIN(TestPlan)
|
||||
|
|
Loading…
Add table