Remove option to apply GFlow at maxdepth in documentation

Option was removed some time ago:
5b080bedde

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
This commit is contained in:
Stefan Fuchs 2017-11-12 20:08:09 +01:00 committed by Jan Mulder
parent ec078f67fc
commit fd2e24d145

View file

@ -3399,10 +3399,7 @@ image::images/Pref4_f23.jpg["FIGURE: Preferences Graph page",align="center"]
respect to inert gas loading and the deeper the ceilings are. Gradient
factors of 20/60 are considered conservative and values of 70/90 are considered
harsh.
In addition decide whether to check the _GFLow at max. depth_ box. If checked, GF_Low is used for the
deepest dive depth and linearly increased up to the GF_High value at the surface. If unchecked,
GF_Low is used between the deepest dive depth and the first deco stop, after which the
gradient factor linearly increases up to the GF_High value at the surface. For more information see:
For more information see:
*** http://www.tek-dive.com/portal/upload/M-Values.pdf[Understanding M-values by Erik Baker, _Immersed_ Vol. 3, No. 3.]