Configure ostc3: Remove obsoleted setting

In firmware version 2.97 the setting 0x38, SETPOINT FALLBACK, has bin
obsoleted and we get a error when trying to write to it.

This removes this setting.

Signed-off-by: Anton Lundin <glance@acc.umu.se>
This commit is contained in:
Anton Lundin 2018-04-25 19:46:43 +02:00 committed by Lubomir I. Ivanov
parent 6582896e7f
commit fd359f5a88
3 changed files with 2 additions and 16 deletions

View file

@ -902,7 +902,7 @@ static dc_status_t read_ostc3_settings(dc_device_t *device, DeviceDetails *m_dev
dc_status_t rc;
dc_event_progress_t progress;
progress.current = 0;
progress.maximum = 57;
progress.maximum = 56;
unsigned char hardware[1];
//Read hardware type
@ -1128,7 +1128,6 @@ static dc_status_t read_ostc3_settings(dc_device_t *device, DeviceDetails *m_dev
READ_SETTING(OSTC3_AGF_LOW, aGFLow);
READ_SETTING(OSTC3_CALIBRATION_GAS_O2, calibrationGas);
READ_SETTING(OSTC3_FLIP_SCREEN, flipScreen);
READ_SETTING(OSTC3_SETPOINT_FALLBACK, setPointFallback);
READ_SETTING(OSTC3_LEFT_BUTTON_SENSIVITY, leftButtonSensitivity);
READ_SETTING(OSTC3_RIGHT_BUTTON_SENSIVITY, rightButtonSensitivity);
READ_SETTING(OSTC3_BOTTOM_GAS_CONSUMPTION, bottomGasConsumption);
@ -1178,7 +1177,7 @@ static dc_status_t write_ostc3_settings(dc_device_t *device, DeviceDetails *m_de
dc_status_t rc;
dc_event_progress_t progress;
progress.current = 0;
progress.maximum = 56;
progress.maximum = 55;
//write gas values
unsigned char gas1Data[4] = {
@ -1395,7 +1394,6 @@ static dc_status_t write_ostc3_settings(dc_device_t *device, DeviceDetails *m_de
WRITE_SETTING(OSTC3_AGF_LOW, aGFLow);
WRITE_SETTING(OSTC3_CALIBRATION_GAS_O2, calibrationGas);
WRITE_SETTING(OSTC3_FLIP_SCREEN, flipScreen);
WRITE_SETTING(OSTC3_SETPOINT_FALLBACK, setPointFallback);
WRITE_SETTING(OSTC3_LEFT_BUTTON_SENSIVITY, leftButtonSensitivity);
WRITE_SETTING(OSTC3_RIGHT_BUTTON_SENSIVITY, rightButtonSensitivity);