mirror of
				https://github.com/subsurface/subsurface.git
				synced 2025-02-19 22:16:15 +00:00 
			
		
		
		
	Remove unused and buggy get_cylinder_used_gas_string() function
It's good that this is unused, because it does the calculations wrong. Due to the gas compressibility the gas use calculations should subtract the gas_volume() values at the differing pressures, not the pressures themselves. Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
		
							parent
							
								
									6d1effe886
								
							
						
					
					
						commit
						ff8392da54
					
				
					 2 changed files with 0 additions and 32 deletions
				
			
		|  | @ -16,7 +16,6 @@ QString get_depth_string(int mm, bool showunit = false, bool showdecimal = true) | |||
| QString get_depth_unit(); | ||||
| QString get_weight_string(weight_t weight, bool showunit = false); | ||||
| QString get_weight_unit(); | ||||
| QString get_cylinder_used_gas_string(cylinder_t *cyl, bool showunit = false); | ||||
| QString get_temperature_string(temperature_t temp, bool showunit = false); | ||||
| QString get_temp_unit(); | ||||
| QString get_volume_string(volume_t volume, bool showunit = false); | ||||
|  |  | |||
|  | @ -626,37 +626,6 @@ QString get_weight_unit() | |||
| 		return QString("%1").arg(translate("gettextFromC", "lbs")); | ||||
| } | ||||
| 
 | ||||
| /* these methods retrieve used gas per cylinder */ | ||||
| static unsigned start_pressure(cylinder_t *cyl) | ||||
| { | ||||
| 	return cyl->start.mbar ?: cyl->sample_start.mbar; | ||||
| } | ||||
| 
 | ||||
| static unsigned end_pressure(cylinder_t *cyl) | ||||
| { | ||||
| 	return cyl->end.mbar ?: cyl->sample_end.mbar; | ||||
| } | ||||
| 
 | ||||
| QString get_cylinder_used_gas_string(cylinder_t *cyl, bool showunit) | ||||
| { | ||||
| 	int decimals; | ||||
| 	const char *unit; | ||||
| 	double gas_usage; | ||||
| 	/* Get the cylinder gas use in mbar */ | ||||
| 	gas_usage = start_pressure(cyl) - end_pressure(cyl); | ||||
| 	/* Can we turn it into a volume? */ | ||||
| 	if (cyl->type.size.mliter) { | ||||
| 		gas_usage = bar_to_atm(gas_usage / 1000); | ||||
| 		gas_usage *= cyl->type.size.mliter; | ||||
| 		gas_usage = get_volume_units(gas_usage, &decimals, &unit); | ||||
| 	} else { | ||||
| 		gas_usage = get_pressure_units(gas_usage, &unit); | ||||
| 		decimals = 0; | ||||
| 	} | ||||
| 	// translate("gettextFromC","%.*f %s"
 | ||||
| 	return QString("%1 %2").arg(gas_usage, 0, 'f', decimals).arg(showunit ? unit : ""); | ||||
| } | ||||
| 
 | ||||
| QString get_temperature_string(temperature_t temp, bool showunit) | ||||
| { | ||||
| 	if (temp.mkelvin == 0) { | ||||
|  |  | |||
		Loading…
	
	Add table
		Add a link
		
	
		Reference in a new issue