Remove unused and buggy get_cylinder_used_gas_string() function
It's good that this is unused, because it does the calculations wrong. Due to the gas compressibility the gas use calculations should subtract the gas_volume() values at the differing pressures, not the pressures themselves. Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
parent
6d1effe886
commit
ff8392da54
2 changed files with 0 additions and 32 deletions
|
@ -16,7 +16,6 @@ QString get_depth_string(int mm, bool showunit = false, bool showdecimal = true)
|
|||
QString get_depth_unit();
|
||||
QString get_weight_string(weight_t weight, bool showunit = false);
|
||||
QString get_weight_unit();
|
||||
QString get_cylinder_used_gas_string(cylinder_t *cyl, bool showunit = false);
|
||||
QString get_temperature_string(temperature_t temp, bool showunit = false);
|
||||
QString get_temp_unit();
|
||||
QString get_volume_string(volume_t volume, bool showunit = false);
|
||||
|
|
|
@ -626,37 +626,6 @@ QString get_weight_unit()
|
|||
return QString("%1").arg(translate("gettextFromC", "lbs"));
|
||||
}
|
||||
|
||||
/* these methods retrieve used gas per cylinder */
|
||||
static unsigned start_pressure(cylinder_t *cyl)
|
||||
{
|
||||
return cyl->start.mbar ?: cyl->sample_start.mbar;
|
||||
}
|
||||
|
||||
static unsigned end_pressure(cylinder_t *cyl)
|
||||
{
|
||||
return cyl->end.mbar ?: cyl->sample_end.mbar;
|
||||
}
|
||||
|
||||
QString get_cylinder_used_gas_string(cylinder_t *cyl, bool showunit)
|
||||
{
|
||||
int decimals;
|
||||
const char *unit;
|
||||
double gas_usage;
|
||||
/* Get the cylinder gas use in mbar */
|
||||
gas_usage = start_pressure(cyl) - end_pressure(cyl);
|
||||
/* Can we turn it into a volume? */
|
||||
if (cyl->type.size.mliter) {
|
||||
gas_usage = bar_to_atm(gas_usage / 1000);
|
||||
gas_usage *= cyl->type.size.mliter;
|
||||
gas_usage = get_volume_units(gas_usage, &decimals, &unit);
|
||||
} else {
|
||||
gas_usage = get_pressure_units(gas_usage, &unit);
|
||||
decimals = 0;
|
||||
}
|
||||
// translate("gettextFromC","%.*f %s"
|
||||
return QString("%1 %2").arg(gas_usage, 0, 'f', decimals).arg(showunit ? unit : "");
|
||||
}
|
||||
|
||||
QString get_temperature_string(temperature_t temp, bool showunit)
|
||||
{
|
||||
if (temp.mkelvin == 0) {
|
||||
|
|
Loading…