Firmware updates can only be done on a newly opened device.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This looks at the OSTC3 hw descriptor and exposes that model info as a
read-only line edit, so you can see in clear text the name of the model
of computer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
All the conflicting fields for suunto vyper configs are named _1, so
rename this one to be in the same style.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This connects up the custom serial code in the configure dive computer
dialogs.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When working with ostc's via bluetooth, they will reboot and exit
bluetooth mode when you send the disconnect command. Thats kinda
inconvenient when you would like to read your settings, change something
and write it back, you need to start bluetooth mode on your device
twice.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds delegates to simplify configuration of setpoint values in the
OSTC's.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The table data is set via role, so retrieve the data via role too.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This switches to use the closeEvent to save settings and cleanup instead
of the destructor.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This enables enables you to configure a couple more settings in the
OSTC devices, roughly corresponding to the new ones that can be
configured in the OSTC3 devices.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This enables enables you to configure a couple of new settings in the
OSTC3 devices.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The DeviceDetails class is just a storage container for passing values
back and forth between backend and ui code. The different names between
the setters and getters just made it a pain to write nice macros and
keeping the two ends in sync, so this just removes the setters and
getters in favor of having the members public.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This copies peaces from the downloadfromdivecomputer dialog into the
configuredivecomputerdialog and connects them to be able to create a
logfile form the configuration of the divecomputer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The reset call hides the progress bar text, and that way it hides our
error messages we try to show with the progress bar.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This switches from a couple of labels in the dialog to a progress bar,
to later being able to use it to provide better user experience.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Lots and lots and lots of header files were being included without being
needed. This attempts to clean some of that crud up.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Previous code suggested a "upgrade" if your firmware where other than
whats parsed from the autofirmware call.
This switches that logic into only suggesting firmware upgrade if the
found firmware is newer than the firmware your device runs.
The previous logic was very annoying if you have a device running a
development version of the firmware. If you have taken that step of the
guided path, you shouldn't be told to "upgrade" to something older
every time you download from your computer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Fix small spelling error in configure dive computer dialog.
Signed-off-by: Joseph W. Joshua <joejoshw@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The OSTC Sport exits bluetooth mode after the loogbook download. To
update the firmware in the OSTC Sport, we need it enabled again, so we
gently remind the user about doing that before continuing.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This caused a crash when trying to call the firmware upgrade from the
downloader - no idea how this worked for the other caller (from the main
menu).
Anyway, with this the "offer to upgrade the OSTC after a download from an
OSTC that doesn't have the latest version" is indeed functional.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This successfully downloads the hex file.
The actuall update of the OSTC fails before it gets started with a crash
when the ConfigureDiveComputer object is created.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Heinrichs Weikamp is giving us stable URLs from which we can get the
latest stable version. The parsing is a bit simplistic, but it seems to
work.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Better parsing of the website data, a simpe dialog that informs the user
that they should upgrade their firmware.
Still doen't call the right code path to DO the upgrade.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This rearranges the code so we can call it from the download dialog and
tell the user if there is a newer version of the firmware available.
This needs a proper dialog and needs to be hooked up so that the user can
accept the suggestion and go directly to the firmware update code.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is only partial. It prints the current version string (to be
processed by a regex) via qDebug().
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This enables the dormant OSTC3/OSTC Sport firmware update code, now when
the hw_ostc3_device_fwupdate call is available in libdivecomputer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The successful message was emitted in a some what older way then the
other messages so it was always emitted, even on error.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This creates a delegate to simplify the handling of gas components and
the change depth.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This creates a delegate for the type column to choose the type value for
gases that is less confusing then the raw value.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
On the OSTC's the salinity is in kg/l and is stored as kg/l * 100
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The OSTC supports a bit different functionalities than the OSTC3 does.
The "unsupported" bits are
setBrightness
setCalibrationGas
setCompassGain
setDiveMode - Bult into setDecoType (OC/CCR)
setDiveModeColor - Lots of different colors
setFlipScreen
setLanguage - Controlled via flashing different firmwares
setPressureSensorOffset
setUnits
setSetPointFallback
setCcrMode - there are some ppO2 reading functionality in the fist gen
OSTC that we don't care about, and the rest is controlled
via choosing a CCR deco algorithm
Also the OSTC have a notion of number of dives it has done, so this adds
ui for that value.
There are also differences in how some values are handled. Ex the OSTC
don't have fixed samplerates that you can choose between. You can rather
just set your sample rate to X seconds.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We currently don't support update firmware for the OSTC3. Where waiting
for support in libdivecomputer for that, so disable that button for now.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Almost all of our other classes have the ui class as a class member in
the controller code. This switches ConfigureDiveComputerDialog to that
model.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Disable the Update Firmware button if you choose a device that we don't
support update firmware for.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>