Commit graph

11 commits

Author SHA1 Message Date
Stefan Fuchs
16f330e6c9 Planner remove unnecessary gas consumption info from notes
If we consumed 0l/0bar in total from a cylinder there is no need to also
state that we consumed 0l/0bar during ascend.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-30 21:45:56 +01:00
Salvador Cuñat
1095b78071 Planner: Do not translate VARIATIONS
This string is substituted with the runtime increments derived of slight
variations in depth or bottom time in:

diveplannermodel.cpp:1058:
displayed_dive.notes = strdup(notes.replace("VARIATIONS", QString(buf)).toUtf8().data());

Translating it avoids substitution and we just get the translated
string.

Signed-off-by: Salvador Cuñat <salvador.cunat@gmail.com>
2017-10-28 08:19:18 +02:00
Stefan Fuchs
4158a4c7de init_deco correctly identify previous dives and report overlapping dives
When changing the date/time of a dive in the planner the dive may end
up in a totaly new position in respect to date/time of other dives in
dive list table. It can be moved to the past or the future before or after
other existing dives. It also could overlap with an existing dive.

This change enables identification of a new "virtual" dive list position
and based on this starts looking for previous dives.
Then it (as before the change) does init the deco calculation with any
applicable previous dive and surface interval.
If some of these applicable dives overlap it returns a neg. surface time
which is then used in the planner notes to prohibit display of results.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-18 23:19:13 +02:00
Stefan Fuchs
ba7be8f335 plannernotes.c coding style fixes
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-18 17:41:42 +02:00
Stefan Fuchs
94e563a94e Minimum gas calculation: Change text colors for delta value output...
and adapt the strings for translation to s.th. which can be handled more
easily.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-18 17:41:42 +02:00
Stefan Fuchs
8786003c11 Planner minimum gas calculation: Print delta pressure in results
Print the delta between the required minimum gas result and the cylinder
pressure at last bottom datapoint in results.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-04 08:46:14 +02:00
Robert C. Helling
a6f186279f Add a checkbox to turn off plan variations
... as those come with a performance penalty

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-09-20 08:54:41 -07:00
Robert C. Helling
aed5b7d267 Show variations in Runtime string
Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-08-29 06:49:44 -07:00
Robert C. Helling
58d7948871 Change color to red if minimum gas is violated.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-08-29 06:49:44 -07:00
Robert C. Helling
c979d9f166 Always show the ascent to the initial deco stop
...even when not showing transitions, this makes the
first stop look more like a stop (since it does not include
several minutes of ascent).

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-08-03 11:17:33 -07:00
Robert C. Helling
b1ccd2fc43 Move planner notes to separate file
Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-05-26 15:44:36 -07:00