For dives with no samples, we crate a fake dive computer with a set of
made-up samples and use those to display the profile.
However, the actual calculations to do the maximum duration and depth
etc were always done with the "real" dive information, which is empty.
As a result, the scale of the plot ended up being bogus, and part of
the dive would be missing.
Trivially fix by just passing the same dive computer information to
calculate_max_limits() that we use for everything else.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This comes with absolutely no gui - so the plan literally needs to be
compiled into Subsurface. Not exactly a feature, but this allowed me to
focus on the planning part instead of spending time on tedious UI work.
A new menu "Planner" with entry "Test Planner" calls into the hard-coded
function in planner.c. There a simple dive plan can be constructed with
calls to plan_add_segment(&diveplan, duration, depth at the end, fO2, pO2)
Calling plan(&diveplan) does the deco calculations and creates deco stops
that keep us below the ceiling (with the GFlow/high values currently
configured). The stop levels used are defined at the top of planner.c in
the stoplevels array - there is no need to do the traditional multiples of
3m or anything like that.
The dive including the ascents and deco stops all the way to the surface
is completed and then added as simulated dive to the end of the divelist
(I guess we could automatically select it later) and can be viewed.
This is crude but shows the direction we can go with this. Envision a nice
UI that allows you to simply enter the segments and pick the desired
stops.
What is missing is the ability to give the algorithm additional gases that
it can use during the deco phase - right now it simply keeps using the
last gas used in the diveplan.
All that said, there are clear bugs here - and sadly they seem to be in
the deco calculations, as with the example given the ceiling that is
calculated makes no sense. When displayed in smooth mode it has very
strange jumps up and down that I wouldn't expect. For example with GF
35/75 (the default) the deco ceiling when looking at the simulated dive
jumps from 16m back up to 13m around 14:10 into the dive. That seems very
odd.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Without this the cairo_close_path call could do silly looking things
(intersecting polygons...).
Reported-by: "Robert C. Helling" <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The old implementation was broken in several ways.
For one thing the GF values are percentages, so they should normally be
0 < GF < 1 (well, some crazy people like to go above that).
With this most of the Bühlmann config constants were wrong.
Furthermore, after we adjust the pressure tolerance based on the gradient
factors, we need to convert this back into a depth (instead of passing
back the unmodified depth - oops).
Finally, this commit adds closed circuit support to the deco calculations.
Major progress and much more useful at this stage.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This also initializes the N2 tissue saturations to correct numbers
(setting them to zero was clearly silly).
With this commit we walk back in the dive_table until we find a surface
intervall that's longer than 48h. Or a dive that comes after the last one
we looked at; that would indicate that this is a divelist that contains
dives from multiple divers or dives that for other reasons are not
ordered. In a sane environment one would assume that the dives that need
to be taken into account when doing deco calculations are organized as one
trip in the XML file and so this logic should work.
One major downside of the current implementation is that we recalculate
everything whenever the plot_info is recreated - which happens quite
frequently, for example when resizing the window or even when we go into
loup mode. While this isn't all that compute intensive, this is an utter
waste and we should at least cache the saturation inherited from previous
dives (and clear that number when the selected dive changes). We don't
want to cache all of it as the recreation of the plot_info may be
triggered by the user changing equipment (and most importantly, gasmix)
information. In that case the deco data for this dive does indeed have to
be recreated. But without changing the current dive the saturation after
the last surface intervall should stay the same.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Usually dive computers show the ceiling in terms of the next deco stop -
and those are in 3m increments. This commit also adds the ability to chose
either the typical 3m increments or the smooth ceiling that the Bühlmann
algorithm actually calculates.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is on top of the deco information reported by the dive computer (in a
different color - currently ugly green). The user needs to enable this via
the Tec page of the preferences.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The existing code had the somewhat retarded Ctrl-C binding for displaying
the next divecomputer and no way to go back to the previous one. With this
commit we use our keyboard grab to map Left and Right to previous and next
divecomputer. Much nicer.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This clarifies/changes the meaning of our "cylinderindex" entry in our
samples. It has been rather confused, because different dive computers
have done things differently, and the naming really hasn't helped.
There are two totally different - and independent - cylinder "indexes":
- the pressure sensor index, which indicates which cylinder the sensor
data is from.
- the "active cylinder" index, which indicates which cylinder we actually
breathe from.
These two values really are totally independent, and have nothing
what-so-ever to do with each other. The sensor index may well be fixed:
many dive computers only support a single pressure sensor (whether
wireless or wired), and the sensor index is thus always zero.
Other dive computers may support multiple pressure sensors, and the gas
switch event may - or may not - indicate that the sensor changed too. A
dive computer might give the sensor data for *all* cylinders it can read,
regardless of which one is the one we're actively breathing. In fact, some
dive computers might give sensor data for not just *your* cylinder, but
your buddies.
This patch renames "cylinderindex" in the samples as "sensor", making it
quite clear that it's about which sensor index the pressure data in the
sample is about.
The way we figure out which is the currently active gas is with an
explicit has change event. If a computer (like the Uemis Zurich) joins the
two concepts together, then a sensor change should also create a gas
switch event. This patch also changes the Uemis importer to do that.
Finally, it should be noted that the plot info works totally separately
from the sample data, and is about what we actually *display*, not about
the sample pressures etc. In the plot info, the "cylinderindex" does in
fact mean the currently active cylinder, and while it is initially set to
match the sensor information from the samples, we then walk the gas change
events and fix it up - and if the active cylinder differs from the sensor
cylinder, we clear the sensor data.
[Dirk Hohndel: this conflicted with some of my recent changes - I think
I merged things correctly...]
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit makes deco handling in Subsurface more compatible with the way
libdivecomputer creates the data. Previously we assumed that having a
stopdepth or stoptime and no ndl meant that we were in deco. But
libdivecomputer supports many dive computers that provide the deco state
of the diver but with no information about the next stop or the time
needed there. In order to be able to model this in Subsurface this adds an
in_deco flag to the samples. This is only stored to the XML file when it
changes so it doesn't add much overhead but will allow us to display some
deco information on dive computers like the Atomic Aquatics Cobalt or many
of the Suuntos (among others).
The commit also removes the old event based deco code that was commented
out already. And fixes the code so that the deco / ndl information is
stored for the very last sample as well.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We only store the model/deviceid/nickname for those dive computers that
are mentioned in the XML file. This should make the XML files nicely
selfcontained.
This also changes the code to consistently use model & deviceid to
identify a dive computer. The deviceid is NOT guaranteed to be collision
free between different libdivecomputer backends...
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Having it there with the model information seemed to make sense but on
second thought it's the wrong spot to keep that information, especially
since we were storing it in the XML file in every single dive.
This change removes the nickname member from the divecomputer and makes
the rest of the code reasonably self consistent. It does not add much of
the new code for the new design to handle nicknames.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds the capability to actually view all your dive computers, by
adding a menu item under "Log"->"View"->"Next DC" to show the next dive
computer.
Realistically, if you actually commonly use this, you'd use the
accelerator shortcut. Which right now is Ctrl-C ("C for Computer"),
which is probably a horrible choice.
I really would want to have nice "next/prev dive" accelerators too,
because the cursor keys don't work very well with the gtk focus issues.
Being able to switch between dives would also make the "just the dive
profile, maam" view (ctrl-2) much more useful.
The prev/next dive in the profile view should probably be done with a
keyboard action callback, which also avoids some of the limitations of
accelerators (ie you can make any key do the action). Some gtk person,
please?
Anyway, this commit only does the dive computer choice thing, and only
using the accelerators.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This changes two things to improve the appearance of the profile:
- the partial pressure scale is now in 0.5 increments if the total is <= 4
and in 1.0 increments if it is > 4.
- the depth marker lines end slightly below the depth chart so that we no
longer have overlap between the depth scale and the partial pressure
scale.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
In profile.c:create_plot_info(), store the last address in which
memory was allocated for the plot data entries in the static
variable "last_pi_entry". If "last_pi_entry" isn't a NULL
pointer in each call to create_plot_info(), free memory at that
address.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We maintain a list of dive computers that we know about (by deviceid) and
their nicknames in our config. If the user downloads dive from a dive
computer that we haven't seen before, we give them the option to set a
nickname for that dive computer. That nickname is displayed in the profile
(and stored in the XML file, assuming it is not the same as the model).
This implementation attempts to make sure that it correctly deals with
utf8 nicknames.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Showing the depth scale all the way to the bottom of the profile plot
looks strange when there are partial pressure graphs down there. So
instead we only plot down to the next marker below the maximum depth of
the actual dive.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I foolishly changed visible_columns in both the (ill-named) cns branch and
master...
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Conflicts:
divelist.c
gtk-gui.c
profile.c
This splits the dive time, depth, pressure and temperature maxima and
minima setup from the per-dive-computer "create_plot_info()" function
into one setup function that walks _all_ the dive computers, so that we
have a global maxima and minima.
That way the graph scaling we set up will now fit the data from all dive
computers rather than just the particular one we are plotting. So if
you switch back-and-forth between computers, the scale (which is defined
by the extremes) remains the same.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Now we can simply remember the state of all the preferences at the
beginning of preferences_dialog() and restore them if the user presses
'Cancel'.
Fixes#21
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Instead provide a scale on the right in a highly transparent grey and rely
on the tooltip available with mouse-over to pinpoint the value at certain
spots with much better accuracy.
Fixes#30
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Some dive computers appear to tell us the gas used in a gaschange event
right at the beginning of the dive. We arbitrary have a cut-off that says
"a gas change in the first 30 seconds shouldn't get a marker".
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Regardless what the dive computer tells us, don't believe that pO2 was
higher than the ambient pressure. This gives much more realistic values.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This now takes the He percentage into account when matching tanks. Given
the encoding of fO2 and fHe in the GASCHANGE2 event, we can simply mask
and shift as if we have a GASCHANGE2 event and things will automatically
work correctly for the regular GASCHANGE event.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Tec divers seem to like a little bit more precision - and the dive
computers certainly provide it (or we can calculate it).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
While having the background "come down" seemed like a good visualization
of the ceiling, some divers appear to prefer something more dramatic. This
adds an option to the Tec Settings to have the ceiling shown in red
instead of the default background color.
Suggested-by: Jan Schubert <Jan.Schubert@GMX.li>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This way they don't clash with the dive computer model information that
was added by commit a23ec27ca7bb "Add dive computer name to the dive
plot".
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
.. and then allocate just the plot-info entry array dynamically.
We want to have a longer lifetime for the basic plot_info data
structure, because we want to do computer selection and maximum
time/depth/temperature computations *before* we start plotting anything,
and before we allocate the plot entry array.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I want to have some way to show multiple dive computers, so start off by
adding the name of the current one. So if we change dive computers,
we'll see it.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit changes the code that was recently introduced to deal with
deco ceilings. Instead of handling these through events we now store the
ceiling (which in reality is the deepest deco stop with all known dive
computers) and the stop time at that ceiling in the samples.
This also adds support for NDL (non stop dive limit) which both dive
computers that appear to give us ceiling / deco information appear to
give us as well (when the diver isn't in deco).
If the mouse hovers over the profile we now add support for displaying the
NDL, the current deco obligation and (if we are able to tell from the
data) whether we are at a safety stop.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I was a little too eager to add the deco feature to Subsurface. Jef and I
went back and forth a few more times and the definition of those events
changed. I guess I shouldn't have commited that code until the
corresponding libdivecomputer code had been pushed.
This commit now brings us in sync with the current master of
libdivecomputer (but should compile with 0.2 as well - only deco events
won't work then).
One issue that I see is that deco / ndl aren't really a good fit for the
event model. I actually disabled the drawing of the little yellow
triangles for ndl events as for example on the Uemis those events are
created whenever the remaining non stop time changes - and that can be
every few seconds.
The correct solution may be to treat this as a function of the samples,
but for now this works and is tested with both OSTC and Uemis SDA.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This actually triggers for one of our insane test dives (test15): it has
no samples, so we created a fake dive computer entry with the a fake
profile in it, but we didn't copy the events over.
Having a dive with no samples, yet having events from the dive computer,
sounds pretty bogus. But that test-case did show that when that bogus
situation happens, we had two independent buglets: (a) we didn't insert
the entries in the fake dive computer entry we used and (b) we would
then mix up the events of the fake dive computer entry with the first
dive computer of a dive.
Fix this, just to make test15 happy again. And eventually, when we
actually plot the information for multiple dive computers, fixing case
(b) would become necessary even for real dives.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
For now we only have one fixed divecomputer associated with each dive,
so this doesn't really change any current semantics. But it will make
it easier for us to associate a dive with multiple dive computers.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Prervent tiny temperature changes from being exaggerated in the plot.
Also, shift pressure plot around a bit (if necessary) to prevent it from
ending in the same space as the temperature plato on the profile graph.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The code in commit f99e1b476b18 "Trim the dive to exclude surface time at
beginning and end" failed rather badly if a dive has no samples at all -
which is true for many of our test dives.
This makes sure that we don't exclude data points if we never set up start
and end times.
Reported-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Commit 6c52e8a2e5 ("Add plotting of the deco ceiling") for some
totally unexplained reason deleted one "else" statement, resulting in
some plot events not having a time at all. Which causes various really
odd issues if you hit that situation, including divide-by-zero etc due
to the difference in times between events being nonsensical.
It's just some odd mistake that was entirely unrelated to the other
changes in that commit.
Add the missing line back in.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This shows the values for all the graphs that are shown (depth,
temperature, tank pressure, pO2, pN2m pHe), but also correctly doesn't
display them when they are turned off or no data is available (prior to
this commit, tank pressure was always shown, even if no pressure samples
were available for the dive).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When we calculate the interval for the tick-marks for the dive, we need
to limit 'i' to be within the size of the array. The code does that
with a "i < 8" check, but the fact is, we must never increment past the
last entry, which is 7 (the size of the array is 8, but the last valid
index is 7).
This only happens for unrealistically long dives. Which you can trigger
either by inputting insane values for a manually created dive, or by
merging two dives that are consecutive, but not close to each other
time-wise (eg on different days ;)
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This extends on our current tooltip logic (which shows events when you
mouse over them) to show tooltips for the whole profile area.
If you mouse over an event, that is still shown in the tooltip, but
even in the absense of events, the tooltip will be active, and mousing
over the profile area will show the time, depth and pressure.
This can certainly be improved upon further, but even in this form it is
useful.
Fixes#9
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We don't change any of the samples, we just don't plot (or consider for
dive time / mean calculations) the samples at the beginning or end of the
dive that are less than a certain threshold under water. Right now that's
an arbitrary 75cm which seems to Do The Right Thing(tm) for the dives I
tried this with - but I'm happy to look at other values if this causes
problems for people with dive computers I do not have access to.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The tec diving preference pane now allows us to set a partial pressure
threshold for each of the three gases. When the partial pressure surpasses
that value, the graph becomes red.
Fixes#12
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We now throw away redundant events, just as we throw away other redundant
data coming from the dive computer. Events are considered redundant if
they are less than 61 seconds apart and identical.
This also improves the display of the remaining events in the profile as
we now show the value of the event, if it is present (for example for a
deco event we show the duration of the deepest stop).
Finally, for events that define a range (so they set the beginning flag
and assume and end flag some time later) we no loger show the triangle but
assume that some other code handles visualizing them (as happens for the
ceiling events).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Based on suggestions from Linus (and a few iterations) we now simply have
the surface (i.e., background color / pattern) come down to where the
ceiling is. And we only do the angry red shading when the diver violates
the ceiling.
I think this looks much better.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Plot a red-shaded area on top of the depth profile to indicate the deco
ceiling (i.e., the area into which it isn't save to ascend at this point
of the dive.
So far this is of very limited use as libdivecomputer doesn't give us the
necessary information to plot this. I have sent patches for the OSTC to
Jef, hoping that he will include them in an update. I don't know how many
other dive computers will make this data available - I still need to add
this to our native Uemis support.
This commit also fixes two cut and paste errors in the previous commit
6540be9bd924 "Process ceiling events and store ceiling data in plot_info".
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The existing implementation failed on dive computers that did gas changes
based on events (instead of tracking them in the sample data like the
Uemis Zurich does that I tested the code with).
This commit moves the calculations slightly later in create_plot_info()
after the gas change events are processed and the plot_info data has been
fixed up. Now this works with the data from Linus' Suunto as well.
Reported-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The pN2 print shouldn't have been committed, but I don't want to try and
rewrite all the commit history. Oh well.
The pressure scale I am ambivalent about. It seems that it should be
useful - but that would require guide lines that coincide with the values
which would really throw off the visual for me. So I added the code, but
left it disabled.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I can't remember why we initially did this instead of ending the
horizontal red line whith the last data point of the pressure profile. But
especially nuw with more graphs shown the one line that extends past the
end of the dive looked really silly.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We always want to print absolute maxima and minima - but not when multiple
consecutive data points all have the same value (this happens, for
example, when printing a pHe plot on non-helium dives - or when the dive
profile includes a brief surface intervall which causes all the partial
pressures to be at their minimum).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Whatever I pick here, there will be dives where the different graphs end
up interfering with each other. I don't think there isn't an easy, generic
solution for this (but I can envision awesome non-easy solutions - they
just don't seem to be worth the effort).
But for most dives that I played with this seems to work pretty well.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The algorithms attempt to identify "interesting" points where the user
might want to know the value of the graph.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Adjust the color for pN2 to the standard for this gas (black). We keep pO2
green (even though the ISO 32 color for that would be white). pHe is
marked in brown (which is the matching standard color).
Calculate correct partial pressures for the synthetic plot info points at
the beginning and end of the dive.
Minor fine tuning to the positioning / scaling of the temperature plot
when partial pressures are plotted.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
So few of my dives are on air that at first I didn't notice - but for
those dives we set the o2 permille to 0 - which of course causes incorrect
(and extremely deadly) pO2 of 0...
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Fairly simplistic change that modifies the way we calculate the "maxdepth"
for a particular dive as that is used to scale the plot vertically.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Not sure this is the best naming scheme (General Settings / Tec Settings)
but it's a start.
The idea is to have the settings that a recreational diver might care
about on the first page, and all the other stuff on the second one. Let's
see how this works out long term. For now I moved OTU over and added
toggles for the different partial pressure graphs (only the pO2 one is
implemented so far).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
So far this is done unconditionally. This already starts some of the
infrastructure for other gases, but so far only O2 is handled.
We also need a pressure scale on the right to make this useful - or we
need to do peek / trough pressure prints like we do for temperature and
depth.
Finally, I think I want to move the plot further down, maybe make the
whole plot area taller if we are plotting partial gas pressures as well.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is intended to be unobtrusive, but add more information for people
who aren't satisfied with the numeric value we put inside the plot to mark
local peaks and troughs.
See ticket #9
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Here is what Linus reported:
I think you have made a mistake in trying to translate some of
libdivecomputer.c
Translating some of those things based on locale is *wrong*, because
they are saved in the XML file.
That covers at least the warnings: they'll get translated when you
import them, and then saved to the XML file as that translation, but
now if you start subsurface in another locale, they will not get
translated back.
So translating XML file contents is fundamentally buggy. It just
shouldn't be done.
So all the "translations" for the event handling are buggy, and
generate crap. Please don't do that. Leave them as English.
And of course he is absolutely right. However, instead of not translating
them at all, this commit fixes things a better way - we now mark the
strings for translation but store the original English strings everywhere
(in the in-memory data structure as well as in the XML file). Only when we
actually display something on the screen (in a tooltip or in the filter
dialog) do we actually translate the strings into the native language.
This should address both Linus' issue and the desire to have localized
event texts.
Reported-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is just the first step - convert the string literals, try to catch
all the places where this isn't possible and the program needs to convert
string constants at runtime (those are the N_ macros).
Add a very rough first German localization so I can at least test what I
have done. Seriously, I have never used a localized OS, so I am certain
that I have many of the 'standard' translations wrong. Someone please take
over :-)
Major issues with this:
- right now it hardcodes the search path for the message catalog to be
./locale - that's of course bogus, but it works well while doing initial
testing. Once the tooling support is there we just should use the OS
default.
- even though de_DE defaults to ISO-8859-15 (or ISO-8859-1 - the internets
can't seem to agree) I went with UTF-8 as that is what Gtk appears to
want to use internally. ISO-8859-15 encoded .mo files create funny
looking artefacts instead of Umlaute.
- no support at all in the Makefile - I was hoping someone with more
experience in how to best set this up would contribute a good set of
Makefile rules - likely this will help fix the first issue in that it
will also install the .mo file(s) in the correct place(s)
For now simply run
msgfmt -c -o subsurface.mo deutsch.po
to create the subsurface.mo file and then move it to
./locale/de_DE.UTF-8/LC_MESSAGES/subsurface.mo
If you make changes to the sources and need to add new strings to be
translated, this is what seems to work (again, should be tooled through
the Makefile):
xgettext -o subsurface-new.pot -s -k_ -kN_ --add-comments="++GETTEXT" *.c
msgmerge -s -U po/deutsch.po subsurface-new.pot
If you do this PLEASE do one commit that just has the new msgid as
changes in line numbers create a TON of diff-noise. Do changes to
translations in a SEPARATE commit.
- no testing at all on Windows or Mac
It builds on Windows :-)
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Tests have shown that the most multi-platform way to do printing with GTK is
to use GTK_UNIT_INCH (or GTK_UNIT_MM) with GtkPrintOperation. Tested on
Linux, OSX, Windows.
However this requires the appropriate scaling for Pango and Cairo to be done,
with separate plotting logic for printing and drawing on the screen. To achieve
that, profile.c:plot() now accepts a scaling parameter from type
"scale_mode_t" defined in "display.h".
Also due to new scale, small decimal numbers (such as 6.12345) cannot be well
stored in "cairo_rectangle_int_t" therefore it is replaced with
"cairo_rectangle_t", which uses doubles to provide Cairo with a drawing
area.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Minor whitespace cleanup.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Freedives can easily exceed the assumed ascent/descent rate, which
results in wacky dive profiles. Add a check to make the ascent and
descent fit within the duration of the dive.
Merge freediving tweaks (zoom in on short dives etc) from Maximilian
Güntner.
Trivial conflicts in display.h due to unrelated printing stuff just
happening to be added nearby.
* 'freediving-tweaks' of git://github.com/mguentner/subsurface:
moved zoomed_plot to display.h
plot the time with a fixed padding (leading zero)
updated/corrected comment
added "Zoom" button and improved scaling
fixed indentation
use increments that make sense for 600 seconds
Plot shorter (apnea) dives with a reasonable scale
The previous commit was a patch from Lubomir, which also had some
whitespace fixes (to go with some new whitespace bugs to replace them)
in it.
I removed the whitespace changes from that patch (don't mix whitespace
fixes with other fixes, unless they are on the same lines!) but decided
to look for other whitespace issues, and this is the result.
I left the non-C files alone, some of the spec and script files also
have whitespace at the end of lines etc.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This completely changes how we keep track of selected dives: instead of
having an array listing the selection ("selectiontracker") or trusting
the gtk selection information, just save the information about whether a
dive is selected in the dive itself.
That makes it trivial to keep track of the state of selection across
group collapse/expand events, or when changing the tree view model. It
also ends up simplifying the code and logic in other ways.
HOWEVER, it does currently (re-)introduce an annoying oddity with gtk:
if you collapse a dive trip that has individual selections, gtk will
forget those selections ("out of sight, out of mind"), and when you do
*new* selections, the old hidden ones remain.
So there's some games required to make gtk do sane things. We may need
to either explicitly drop selections when collapsing trips, or make sure
the group entry gets selected when collapsing a group that has
selections in it. Or something.
There may be other issues introduced by this too.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The code iterates over a list that can be NULL, but happily dereferenced
it anyway. Oops.
This function really should be split up and commented more.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Pull miscellaneous fixes, mostly UI stuff from Mikko Rasa.
Both this and the pull from Pierre-Yves Chibon created a "Save As" menu
entry and logic. As a result, there were a fair number of conflicts,
but I tried to make the end result somewhat reasonable. I might have
missed some semantic conflict, though.
Series-acked-by: Henrik Brautaset Aronsen <subsurface@henrik.synth.no>
* 'misc-fixes' of git://github.com/DataBeaver/subsurface:
Add a separate "Save as" entry to the menu
Changes to menu icons
Improved depth info for dives without samples
Divide the panes evenly in view_three
This fixes the bug that triggered the SIGSEGV that Linus worked around
earlier. I had forgotten to update this call path to the
edit_multi_dive_info function.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This calculates a mean depth for the dive with a fixed ascent/descent
rate and an assumption that all of the bottom time is at the maximum
depth. It's not much, but it allows some derived values such as SAC to
make more sense.
The depth profile for such dives is now also generated with the same
assumptions instead of putting the samples at fixed percentages of the
dive duration.
Signed-off-by: Mikko Rasa <tdb@tdb.fi>
It should be possible to have a certain limit where we
stop zooming so that short dives are visible as such
at first glance. Therefore a "Zoom" button has been
added to the "Log" menu along with a shortcut (Ctrl + "0").
The user can now zoom/unzoom the plot and is still able to
quickly distinguish short dives from normal ones when
browsing the log.
Signed-off-by: Maximilian Güntner <maximilian.guentner@gmail.com>
The time marker increments have also been changed to better values.
Also, display more time information for short dives.
Signed-off-by: Maximilian Güntner <maximilian.guentner@gmail.com>
Fix ugly printout, give colors proper names, make grid lines and alert
marker easier to see, and specify printer colors independently.
Signed-Off-By: Henrik Brautaset Aronsen <subsurface@henrik.synth.no>
The profile colors were defined all over the place, so I put them all in one spot. I'm unsure if this is the best solution to that problem, but I guess it's a step in the right direction.
Signed-Off-By: Henrik Brautaset Aronsen <subsurface@henrik.synth.no>
The profile colors aren't very pretty, and the grid lines are too thick.
This commit tries to improve that.
Signed-Off-By: Henrik Brautaset Aronsen <subsurface@henrik.synth.no>
We do all the pressures in mbar, which has plenty of precision for
interpolated pressures - even when we then do our discrete integration
over many samples.
However, when we calculate those interpolated pressure points, we should
make sure that we round the result correctly, otherwise the consistent
rounding errors (from truncating the FP value into our integer mbar
values) will result in a final pressure that is noticeably off in ugly
ways (ie "end pressure set by hand to 750 mbar, but shown as 748").
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This reverts commit abdee5b1b8.
There's no point in doing random hacks. Instead, do the intermediate
pressure calculations with proper rounding instead of always truncating
to mbar. With the math done correctly we have enough precision that the
end result of the pressure interpolation doesn't have the kind of errors
that caused Dirk to try to fix things up later.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
While printing the last pressure in the calculated sequence may seem more
logical, given that the discrete series will create some amount of error
this simply looks wrong. Instead we pick the end pressure that was
manually set.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Some parts of the existing code used the depth at the time of the sample
to calculate the sac rate - it makes much more sense to use the average
depth. But that requires us to loop over the entries and average the
individual sac rates per segment instead of just using the beginning and
end depth of the multi-segment interval we use for smoothing purposes.
This may seem like a subtle detail, but it does in fact matter when we
plot the synthetic tank pressure values that we create when we have no
tank pressure data in the samples.
Another detail we change here is to not artificially start with a forward
looking segment of the full SAC_WINDOW but instead just start with the
first two data points and then simply let the time window grow until it
hits SAC_WINDOW - at which point it becomes a sliding window.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This changes the algorithm that picks the sac color to consider
+/- 1 l/min to be the same color (before the color changed every
time you crossed above or below the average which looked silly with
our synthetic "constant sac" values as those are discrete and oscilate
around the average.
This also changes the order in which things are drawn so so that the
pressure plot goes over the depth profile plot (so the red shading of the
dive no longer changes the color of the tank pressure plot).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>