Identify previous dives for CNS calculation in a similar way as it
is done for previous dives for deco calculation.
This is done to identify the previous dives dynamically when moving
around date/time of a dive in the planner.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
When changing the date/time of a dive in the planner the dive may end
up in a totaly new position in respect to date/time of other dives in
dive list table. It can be moved to the past or the future before or after
other existing dives. It also could overlap with an existing dive.
This change enables identification of a new "virtual" dive list position
and based on this starts looking for previous dives.
Then it (as before the change) does init the deco calculation with any
applicable previous dive and surface interval.
If some of these applicable dives overlap it returns a neg. surface time
which is then used in the planner notes to prohibit display of results.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
Calculating dive.when + dive.duration doesn't always give the correct
endtime of a dive especially when a dive has surface interval(s) in
the middle.
Using the helper function dive_endtime() fixes this issue.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
In commit e1b880f4 "Profile support for multiple concurrent pressure
sensors" I had mindlessly hacked away at some of the sensor lookups from
the plot entries to make it all build, and forgotten about my butchery.
Thankfully Jan and Davide noticed in their multi-cylinder deco dives
that the deco calculations were no longer correct.
This uses the newly introduced "get_gasmix()" helper to look up the
currently breathing gasmix, and fixes the deco calculations.
Reported-and-tested-by: Jan Mulder <jlmulder@xs4all.nl>
Reported-by: Davide DB <dbdavide@gmail.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is a very timid start at making us actually use multiple sensors
without the magical special case for just CCR oxygen tracking.
It mainly does:
- turn the "sample->sensor" index into an array of two indexes, to
match the pressures themselves.
- get rid of dive->{oxygen_cylinder_index,diluent_cylinder_index},
since a CCR dive should now simply set the sample->sensor[] indices
correctly instead.
- in a couple of places, start actually looping over the sensors rather
than special-case the O2 case (although often the small "loops" are
just unrolled, since it's just two cases.
but in many cases we still end up only covering the zero sensor case,
because the CCR O2 sensor code coverage was fairly limited.
It's entirely possible (even likely) that this migth break some existing
case: it tries to be a fairly direct ("stupid") translation of the old
code, but unlike the preparatory patch this does actually does change
some semantics.
For example, right now the git loader code assumes that if the git save
data contains a o2pressure entry, it just hardcodes the O2 sensor index
to 1.
In fact, one issue is going to simply be that our file formats do not
have that multiple sensor format, but instead had very clearly encoded
things as being the CCR O2 pressure sensor.
But this is hopefully close to usable, and I will need feedback (and
maybe test cases) from people who have existing CCR dives with pressure
data.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is important to not duplicate code for the Qml
view. Now the DownloadFromDiveComputer widget is mostly
free from important code (that has been upgraded to the
core folder), and I can start coding the QML interface.
There are still a few functions on the desktop widget
that will die so I can call them via the QML code later.
I also touched the location of a few globals (please, let's
stop using those) - because it was declared on the
desktop code and being used in the core.
Signed-off-by: Tomaz Canabrava <tcanabrava@kde.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Not using lrint(f) when converting double/float to int
creates rounding errors.
This error was detected by TestParse::testParseDM4 failure
on Windows. It was creating rounding inconsistencies
on Linux too, see change in TestDiveDM4.xml.
Enable -Wfloat-conversion for gcc version greater than 4.9.0
Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
Using gcc option "-Wfloat-conversion" is useful to catch
potential conversion errors (where lrint should be used).
rint returns double and still raises the same warning,
this is why this change updates all rint calls to lrint.
In few places, where input type is a float, corresponding
lrinf is used.
Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
This resets the maximum crushing pressures and the maximal
ambient pressure between repetitive dives to prevent anomalies
that a dive produces a shorter deco when following another one
than without.
Reported-by: sfuchs@gmx.de
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
There were two problems in the calculation of tissue pre-
saturation from previous dives: We added the surface interval after
the dive rather than before and when also took dives into accout
that were in the future of the dive considerd.
Reported-by: Timothy Massey
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
It turns out that we are starting to have users that have logs that go
back that far. It won't be common, but let's get it right anyway.
NOTE! With us now supporting dates earlier in 1900, this also makes
"utc_mktime()" always add the "1900" to the year field. That way we
avoid ever using the fairly ambiguous two-digit shorthand.
It didn't use to be all that ambiguous when we knew that any two-digit
number less than 70 had to be 2000+. Now that we support going back to
earlier in the last centiry, that certainty is eroding.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If we want to keep the selected dive "close" to where it was before an
operation (whether a delete, or a reload, or something like that), then
the most intuitive thing to do appears to be to select either the same
dive again (if it still exists), or one very close to it in time. This
helper allows us to identify the dive in the current dive list that is
closest to the given time.
We do this in the C code to ensure that we look at all dives in the
dive_table - based on the id that is returned the UI can then figure out
where this dive is currently shown.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Having subsurface-core as a directory name really messes with
autocomplete and is obviously redundant. Simmilarly, qt-mobile caused an
autocomplete conflict and also was inconsistent with the desktop-widget
name for the directory containing the "other" UI.
And while cleaning up the resulting change in the path name for include
files, I decided to clean up those even more to make them consistent
overall.
This could have been handled in more commits, but since this requires a
make clean before the build, it seemed more sensible to do it all in one.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2016-04-04 22:33:58 -07:00
Renamed from subsurface-core/divelist.c (Browse further)