This will allow us to download the dives from the dive computer into a
separate table just for that purpose and not into the main dive_table.
I really dislike the code that's in place that dates back to the very
earliest code written for Subsurface. Dumping the dives straight into the
main dive_table seems really stupid to me.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This parses the dive profile from Divesoft Freedom log file. Only the
depth profile is currently supported. There is also something wrong as
the log file cannot be given as parameter but must be opened or imported
once Subsurface is running. Note that so far no metadata is parsed.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This code sets the parameters properly to support the new fields in
manual CSV import.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This implements importing of dive profile and temperature graph along
with some meta data from a Cobalt Divelog database.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We are quite inconsistent when it comes to reporting back errors.
One case where this caused somewhat unexpected behavior was when the
user would try to open a .csv file by passing it as command line
argument. The file was silently ignored, but treated as if it had been
opened successfully.
Now we issue a somewhat reasonable error message.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We when comparing floating points we do a relative comparison of the difference.
This fails when both numbers are (exactly) 0.0 which happens to occur when plotting
an O2 graph without o2 data resulting in both min and max for the y-axis to be 0.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Change the meaning that _the_ cylinder (as we treat it in OC dives) is the
diluent cylinder (rather than the O2 cylinder). This eliminates special
cases. Now, for CCR, we have to handle the O2 cylinder in addition
(rather than the diluent in addition).
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch is bigger than necessary because I also renamed the
get_cylinder_use() function to the much more accurate
get_cylinder_idx_by_use().
If we have no gas changes (except for a possible explicit first gas),
(which in the CCR case also means no bailout), this code will give you
correct per cylinder depth and duration for oxygen and diluent and
therefore create more reasonable gas consumption data for CCR dives.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Oddly we already had code to load this from XML, but nothing else.
This makes the load from XML work like the rest of our code and adds the
save to XML plus the load and save for the git format.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Add a time linear gas interpolation strategy. Some minor changes.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This implements import from Suunto DM5 database, but there is something
wrong with some of the sample dives in the database I received as
sample. It seems that we should detect missing/bogus data and treat it
properly as divelogs.de does with the same dives. Anyway, when we have
proper data, this import appears to produce sensible results.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
For our usage the method will acept UTF-8 paths,
which are converted to UTF-16 on Win32.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Depth is often mentioned in a length unit, but what we care about is
pressure. When diving in fresh water the pressure is lower than the same
depth in salt water. This adds support for using different salinities in
planning.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This way other parts of the code can act on the "hidden_by_filter" state.
This also cleans up the way we track if a dive is hidden - do it in the
multi filter instead of the individual filters.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This recognizes recognize some strigns (serial number and firmware
version), and the ones that it doesn't recognize it adds as extra data
using Dirk's new interface.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This extra_data is designed to hold unstructured data from the dive
computer. Things like battery voltage. Deco algorithm. Whatever the dive
computer wants to report to us.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Calculations for passive semi-closed rebreathers are pretty much like OC
except the pO2 is lower bey a certain (SAC dependent) factor. This patch
introduces the corresponding calculations in case dctype == PSCR which is
so far never set and there is currently no UI for these calculations. As
pO2 is SAC dependent it takes a certain attempt at getting it and drops to
defaults from the prefs otherwise.
As there is no UI at this point and I also don't have any dives, this has
not received much testing, yet, but it compiles. At least.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Currently the gas pressures stored in structures of pressure are
calculated using the gasmix composition of the currently selected
cylinder. But with CCR dives the default cylinder is the oxygen
cylinder (here, index 0). However, the gas pressures need to
be calculated using gasmix data from cylinder 1 (the diluent
cylinder). This patch allows setting the appropriate cylinder
for calculating the values in the structures of pressure. It
also allows for correctly calculating gas pressures for any
open circuit cylinders (e.g. bailout) that a CCR diver may
use. This is performed as follows:
1) In dive.h create an enum variable {oxygen, diluent, bailout}
2) Within the definition of cylinder_t, add a member: cylinder_use_type
This stores an enum variable, one of the above.
3) In file.c where the Poseidon CSV data are read in, assign
the appropriate enum values to each of the cylinders.
4) Within the definition of structure dive, add two members:
int oxygen_cylinder_index
int diluent_cylinder_index
This will keep the indices of the two main CCR cylinders.
5) In dive.c create a function get_cylinder_use(). This scans the
cylinders for that dive, looking for a cylinder that has a
particular cylinder_use_type and returns that cylinder index.
6) In dive.c create a function fixup_cylinder_use() that stores the
indices of the oxygen and diluent cylinders in the variables
dive->oxygen_cylinder_index and dive->diluent_cylinder_index,
making use of the function in 4) above.
7) In profile.c, modify function calculate_gas_information_new()
to use the above functions for CCR dives to find the oxygen and
diluent cylinders and to calculate partail gas pressures based
on the diluent cylinder gas mix.
This results in the correct calculation of gas partial pressures
in the case of CCR dives, displaying the correct partial pressure
graphs in the dive profile widget.
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This isn't Cobalt specific, this is specific to dive computers that
indicate the first tank that's in use with a gaschange event that
coincides with the first sample.
We need to make sure that we suppress showing that gas change event
(regardless which cylinder it goes to) and instead set the correct
cylinder index from the very start of the dive.
This works with the test data I have and doesn't seem to break thing with
any of the files that I tried... but I'm worried that this is not the
right way to do things.
Fixes#742
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This prevents a warning caused by -Waddress, that the address
of 'displayed_dive' will always be defined.
Exact macro variant suggested by Dirk.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This will parse date information from Seabear log file and skips the
"header" data to allow parsing of the CSV content.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch adds support for importing the logs from a Poseidon MK6
rebreather. This DC produces logs that contain of a .txt file that has
all the meta data and a .csv file that contains the sample readings. The
CSV file is different from the others in that it has a line per each
sample reading at given time. Thus we have to merge all the lines from
one point in time into one sample reading of ours.
[Dirk Hohndel: addressed some compiler warnings]
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The latest CCR patches had rendered the planner not usable for CCR dives.
This patch corrects this (and reenables the CCR set point column for
segments). The problem was that a new member setpoint of struct divepoint
had been introduced, but there was already po2 which had the same meaning.
This patch merges the two and renames them setpoint to prevent future
confusion.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch responds to the side effects that the CCR code has had with
respect to ceilings in OC dives and dive plans. Dive ceilings are now
calculated correctly again.
The following were performed:
1) remove the oxygen sensor and setpoint fields from the gas_pressures
structure.
2) Re-insert setpoint and oxygen sensor fields in the plot_data structure.
3) Remove the algorithm that reads the o2 sensor data and calculates the
pressures.po2 value from function fill_pressures() in dive.c and save
it as a separate function calc_ccr_po2() in profile.c.
4) Activate calc_ccr_po2 from function fill_pressures() in profile.c.
5) Move the relative position of the call to fill_pressures() within the
function create_polt_info_new() in profile.c.
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch adds code to the function fillpressures() in dive.c to
allow calculating o2 pressures, based on the data from the po2
sensors in the system. The following changes were made:
1) add code to perform po2 calculations for CCR with 1, 2 or 3
oxygen sesnors.
2) Add four fields to the gas_pressures structure in dive.h. This
allows communication of data between the function that calls
get_pressures() and the return of partail pressure values to the
calling function.
3) Delete the fields for setpoint and gas partial pressures from
the structure plot_info. All partial pressures (from instruments
as well as calculated) now reside in the pressures structure
that forms part of plot_info.
4) Perform changes in several parts of profile.c to make use of the
pressures structure in plot_info.
[Dirk Hohndel: yet again massive whitespace cleanup]
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch does three things:
1) A new function fill_o2_values() is added to profile.c. This
fills all oxygen sesnsor and setpoint values that have been
zeroed before in order to save space in the dive log. This
recreates the full set of sensor values obtained from the
original CCR xml log file.
2) Function fill_o2_values() is activated in function create_
plot_info_new() in profile.c
3) The calling parameters to function fill_pressures() in dive.c
are changed. The last parameter is now a pointer to a structure
of divecomputer. This will be needed in the last patch of the
present series of three patches.
[Dirk Hohndel: minor whitespace cleanup]
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Decode the gasmix data into a sane format when creating the event, and
add the (currently unused) ability to specify a gas change to a
particular cylinder rather than (or in addition to) the gasmix.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch introduces a new structure holding partial pressures (doubles in bar) for
all three gases and a helper function to compute them from gasmix (which holds fractions)
and ambient pressure. Currentlty this works for OC and CCR, to be extended later to PSCR.
Currently the dive_comp_type argument is unused.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch implements a separation of the code for gas pressure
calculations from the rest of the code in profile.c. The latter
file is now split into: profile.c and gaspressures.c. The
details of the transferred functions is given at the top of
gaspressures.c. The following chnages were made:
1) dive.h: The function types of calculate_depth_to_mbar
and depth_to_mbar were made non-static in order to make them
available within gaspressures.c.
2) profile.c: Prototypes for the functions in gaspressures.c
were inserted at the top of profile. Ten functions were
transferred from profile.c to gaspressures.c
3) gaspressures.c as well as a short header, gaspressures.h
were created.
For the gas pressure calculations for CCR dives, gaspressures.c
forms the immediate basis for further code development.
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
With this information, when we re-plan a dive we can bring the user right
back to the point where they ended - they have the waypoints in the dive
pointes table and handles are shown on the right points in the profile -
and the rest of the dive is once again calculated by the planning
algorithm.
For now this state is lost when saving the dive file as we don't add this
flag in the sample to our saved files. So if we don't find any samples
marked as manually added we add ALL of the samples as way points on the
diveplan and the user has to manually remove the ones that were
calculated.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The old implementation was... let's call it creative.
This tries to actually get things right instead of using magic.
Don't pretend that double values are ints.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit doesn't do anything, yet. It just puts in place helper
infrastructure that will later allow us to cut and paste parts of the data
of one dive into another dive (or set of dives).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
So far, the fields for the two SAC rates did not show a unit and were implictly l/min.
Now they respect the settings for volume units. This was harder than I thought for two reasons:
1) Imperial units for SAC are cuft/min but a typical value would be .70. So I made the point
the field prefix and what is entered is actually hundreth of cuft per minute.
2) I had to get the rounding right in order not to get effects like 20l/min become .70 cuft/min (19800 ml/min
internally) which would then become 19l/min when switching back.
While being at it, I gave the gradient factors '%'-signs as units.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We had pointers to data structures on the stack which we frequently
reallocated. These data structure contain basically a filename and an
offset. We then create a hash of the pointers to those datastructures with
the filename being the key. And then we passed those pointers around
through a Qt model(!!!) only in order to then later look up by filename
what the offset might be.
I am at a loss for words for the lunacy behind this design.
How about we just remember the offsets and pass the integers around?
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
With very low values of GFhigh and setting the last stop depth to 6m it
is possible to create dives that need infintie decompression time.
This ends deco after 48h and replaces the dive plan with an error message.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Almost invisible, mostly looking like an odd bug in the profile code,
there was a tiny red line at depth 0 in the planned profile. Turns out
that was the missing mean depth. We didn't populate enough data in the
dive computer of the dive we generated from the plan (and the length of
the depth line was incorrectly determined by the duration of the dive
instead of the duration stored in the dive computer).
Fixes#570
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>