The backend needs to convert the firmware and serial information into a
sane string - Subsurface shouldn't try to do this by itself.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is not the right way to get serial numbers and firmware versions. The
libdivecomputer interface here is simply broken. Those ARE NOT numbers.
But until we have the capability in libdivecomputer to return reasonable
strings to us, this could be a stop gap measure to help us understand how
these are formatted.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
For our usage the method will acept UTF-8 paths,
which are converted to UTF-16 on Win32.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If an import fails, the permissions of the device are tested and an
error message that mentions permissions is shown to the user.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This should have been ripped out as part of commit 4be7604634 ("Use
libdivecomputer tank size when available").
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Silly type made us always get tank 0. So tanks 1 through n where wrong
(and repeating tank 0 instead).
Reported-by: Jef Driesen <jef@libdivecomputer.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If the gasmix of a tank is not the matching gasmix in the list of
gasmixes, issue a warning (as so far we assume those are always in sync).
This patch removes our own parsing of the sizes because Subsurface 4.3
will require libdivecomputer 0.5 so this should be enabled by the time the
next release comes out, so let's just drop the redundant code.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
libdivecomputer recently gained a api for telling us which mode the
divecomputer was running in, so this uses that to tell us if it was a OC
or CCR dive.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The calculate_string_hash is only used if DC_FIELD_STRING is defined, so
this removes a warning for everybody who doesn't build against a
libdivecomputer with DC_FIELD_STRING support.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Parse air temperature and water temperature if available from the dive
computer. Subsurface happily tracks the temperatures in the dive samples,
but for water temperature in the header ("overall" water temperature) we
currently support only one field. So I ordered the code so that if it is
available, the minimum water temperature will be used, absent a minimum
water temperature we use the maximum water temperature.
Side note:
Since the libdivecomputer maintainer disagrees with the Subsurface
developers regarding a sane way to allow a consumer of his library to
detect if a feature is supported in a particular commit of the library,
the way we decide whether to build this code or not is decidedly hacky.
DC_GASMIX_UNKNOWN happens to be a #define we can check that was added
right around the time the temperature support was added. Sadly there is
no #define that we could check to see if temperature fields are supported.
How insane is that...
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This recognizes recognize some strigns (serial number and firmware
version), and the ones that it doesn't recognize it adds as extra data
using Dirk's new interface.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Normally, all samples have depths associated with them, and most dive
computers likely don't even have the concept of a sample without a depth.
However, the new Suunto EON Steel definitely has samples with just time
updates (and perhaps other data, like events) and no depth at all. We
get unhappy about that, and interpret it as having a zero depth. Which
doesn't look very nice.
This just makes all samples default to the same depth as the previous
sample. For normal samples with a depth value, that will just override
that default.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The latest CCR patches had rendered the planner not usable for CCR dives.
This patch corrects this (and reenables the CCR set point column for
segments). The problem was that a new member setpoint of struct divepoint
had been introduced, but there was already po2 which had the same meaning.
This patch merges the two and renames them setpoint to prevent future
confusion.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds a checkbox for the divecomputer download dialog that allows you
to tell the download to put the newly downloaded dives into a trip of
their own. That in turn will disable the dive merging with any existing
dives, which means that you will not mix up your newly downloaded dives
with any old dives.
That, in turn, is very convenient of you know that some of the dives were
done by other divers (or from testing that happened during servicing etc),
or the dive dates etc were wrong because the dive computer date had reset
due to battery changes etc.
Once you have all the dives in a private trip of their own, you can then
fix them up (delete dives you don't want to merge etc), and then after all
the data is ok you might want to merge the cleaned-up results with
previous trips etc, and then manually ask subsurface to merge the dives or
whatever.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This gets us consistent date format everywhere. The reordering of month
name and day of the month didn't work correctly on Windows, anyway.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Fist is really obvious. I quite regularly decompress using pure O2.
It's as good a last decompression gas as you get.
The second is a bit harder. There are very few that dive with 80%+ helium
in their mixes but they exist, and there are real weirdos that dive
heliox, so they are actual diveable gases too.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
1) All the variables in the sample structures are strongly typed
2) Two additional types were declared in units.h:
o2pressure_t
bearing_t
3) The following variables were added:
diluentpressure
o2setpoint
o2sensor[3]
4) Changes to a number of files were made to chanf
sample->po2 to sample->po2.mbar
bearing to bearring.degrees
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
commit d681bdcb63 ("Only use default cylinder for first one") has a
stupid bug in that it only calls get_tanksize for the first tank. That's
of course completely bogus.
Thanks to Linus for catching this.
Reported-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When downloading from a divecomputer it makes little sense to assume that
all tanks are the default cylinder.
There's a good case to be made for having a default first cylinder (you
always dive with your own cylinder, or you are always on a dive boat with
AL80 tanks), but in multi-cylinder situations this is much more likely to
cause unintended harm; for example for those dive computers that always
report their maximum number of cylinders, even if some of them aren't
used. Here setting a default cylinder turns those entries from obviously
empty into something that appears to have meaning (i.e., cylinder type is
filled in) even though this was just a default added by Subsurface.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
clang-format doesn't appear to reindent multi line #define statements
correctly - so this hopefully will clean those up.
The included whitespace corrections to the code should stay in place when
using the updated tool.
This includes cleaning up some multi-line comments that were messed up the
last time around as well as a few other minor changes.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
tissue_tolerance wasn't used after it was assigned.
type was overwritten after it was assigned.
serial was overwritten after the last /= 100.
event is assigned in the for loop.
clear isn't used after the assignment
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I know everyone will hate it.
Go ahead. Complain. Call me names.
At least now things are consistent and reproducible.
If you want changes, have your complaint come with a patch to
scripts/whitespace.pl so that we can automate it.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Before that, the behaviour was that in case of an error or a
re-download, the progress bar would appear for a few milliseconds with
the old value.
Signed-off-by: Danilo Cesar Lemes de Paula <danilo.eu@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
rint() is "round to nearest integer", and does a better job than +0.5
(followed by the implicit truncation inherent in integer casting). We
already used 'rint()' for values that could be negative (where +0.5 is
actively wrong), let's just make it consistent.
Of course, as is usual for the messy C math functions, it depends on the
current rounding mode. But the default round-to-nearest is what we want
and use, and the functions that explicitly always round to nearest
aren't standard enough to worry about.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We should *not* default to the incorrect "1 bar". Instead, we should
leave the resuling pressure at 0 mbar, which leaves visual entries empty
and uses the default surface pressure for calculations.
Reported-by: Pedro Neves <nevesdiver@gmail.com>
Cc: Patrick Valsecchi <patrick@thus.ch>
Cc: Dirk Hohndel <dirk@hohndel.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
libdivecomputer already supports this, but we didn't save it.
Tested-by: Oscar Isoz <jan.oscar.isoz@gmail.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Libdivecomputer wants us to return true if it should continue to loop over
the dives and false if we want to stop. Don't pass errors back.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Earlier we converted the C++ code to using true/false, and this converts
the C code to using the same style.
We already depended on stdbool.h in subsurfacestartup.[ch], and we build
with -std=gnu99 so nobody could build subsurface without a c99 compiler.
[Dirk Hohndel: small change suggested by Thiago Macieira: don't include
stdbool.h for C++]
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
For some devices, the event data contains important data that is
required for parsing the dives, but which is not present in the full
memory dump.
Signed-off-by: Jef Driesen <jefdriesen@telenet.be>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
C99 7.1.4, says nothing about passing NULL to fopen(),
which means that it isn't portable and there are no guaranties
that the return will be a NULL pointer or that that a library
implementation will not assert or SYSSEGV in the middle of the
fopen() branch.
libdivecomputer.c's 'dumpfile_name' and 'logfile_name' could
cause problems in that regard.
A possible fix for #411
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If first sample is not a DC_SAMPLE_TIME, we would have bin dereferencing
a null pointer.
This might actually never happen, unless we talk to a really weird dc,
but this makes the static analyzer happier.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We have allot of helpers, use them instead of local variants.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is super-simplistic and also is kinda wrong. It forces all tanks that
haven't been specified by the DC (so far only Atomics Aquatics Cobalt and
UEMIS Zurich (which doesn't even use libdivecomputer) to be AL80. Just as
we used AL80 as default for manually adding tanks.
Obviously this needs to become an option where the user can pick.
See #145
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This may seem like a really odd change - but with this change the Qt tools
can correctly parse the C files (and qt-gui.cpp) and get the context for
the translatable strings right.
It's not super-pretty (I'll admit that _("string literal") is much easier
on the eye than translate("gettextFromC", "string literal") ) but I think
this will be the price of success.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
libdivecomputer doesn't give the salinity in kg/l, but in g/l and
subsurface works with g/10l. So the salinity was too big by a factor
of 1000.
Signed-off-by: Patrick Valsecchi <patrick@thus.ch>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>