If input is in F, we need to convert it to C on import.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Include the DC's hardware name if it was given as parameter on CSV
import.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This looks if we're importing any o2 values form the csv file, then its
probably a CCR dive.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Instead of replacing all the empty model tags after a csv to xml
transform with some text, just produce that text in the csv to xml
transform instead.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds support for importing individual O2 sensors from a CSV file,
e.g. an APD log viewer file.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We got additional slashes in front of the site if country and/or
location was missing.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
As the gas changes can be parsed more reliably from the gases list, we
just ignore the gas_change events as redundant information.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Gas change events can be parsed properly from the gases list with clear
information on what the gas mixture was.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This includes all the data computer related data within the divecomputer
tag. All the extra noise is just indentation (apart from moving the
divecomputer end tag).
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Next commit will do indentation so this one will keep it clear of what
actually occurs.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Rounding always up should give us sensible sample interval as EON Steel
adds extra samples.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The logic to select samples from EON Steel for divelogs.de export is the
following:
- Ignore sample at time zero, as that is surface, and the second "odd"
sample contains information we are interested in
- Grab the second sample, first sample with pressure and temperature
readings
- Grab the third sample - "grand parent" is 0, thus our first interval
sample
- Grab the samples when the predecessor (or grand parent) is at least 10
seconds away
This logic seems to produce reasonable results when exporting EON Steel
logs to divelogs.de. Naturally there might be corner cases, that are not
taken into account, but this basic logic seems reasonable in normal
cases. (Unfortunately analysis is done based on a single dive.)
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This sets the Suunto EON Steel sample interval to 10 seconds when
exporting to divelogs.de.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This add support for Seabear's new import format that is used by H3 and
T1. In the future also the Hudc should switch to the new format. The
main difference to the old one is that time stamps are no longer
recorded in the samples, but intervali is specified in the header.
The header contains other useful information as well that we should
build support for. E.g. surface pressure, gas mixes, GF, and mode might
be useful additions later on.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The manuals all will need a careful read.
The changes to use lsb-release and the PCLinuxOS specific files got lost
because I didn't want to try to rewite this in the middle of a merge.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Conflicts:
Documentation/50-pot/subsurface-manual.pot
Documentation/fr/po/subsurface-manual.fr.po
Documentation/user-manual.txt
Documentation/user-manual_es.txt
Documentation/user-manual_fr.html.git
Documentation/user-manual_fr.txt
Documentation/user-manual_ru.html.git
Documentation/user-manual_ru.txt
file.c
qthelper.cpp
subsurface.pro
subsurfacesysinfo.cpp
xslt/DiveLog.xslt
This adds a bit more information to dive notes on DiveLog import.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I originally thought about converting the time as well, but my fingers
were too slow and memory too short to actually do that :D
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds a bit more information to dive notes on DiveLog import.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I originally thought about converting the time as well, but my fingers
were too slow and memory too short to actually do that :D
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Since UDDF import uses different namespaces, we need to count the
temperature samples in all of them to get temperature readings from
waypoints.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Should have removed the getFieldByIndex template from these files when
it was moved to commonTemplates. Otherwise these imports wont work.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This will export the cylinder information to divelogs.de also if there
is a pressure drop of at least 5 bars. (Previously only a gas switch to
the gas triggered the export of that particular cylinder.)
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Implementation of getFieldByIndex on this file does not support
quotation so lets use a template that is developed further.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The profile export now uses Sample time, etc. on profile export as that
is the naming we use on import as well.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We need a special case to import tags on our own CSV export as there is
no field separator at the end of the line.
See #814
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Discarding header lines was faulty as the test whether dive number was
numeric did not work properly.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Use tab as separator when exporting dive details to CSV file. This also
replaces tabs and line feeds from notes with spaces.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I am a bit baffled as to how this used to work before and does not work
anymore. Anyway, it should be sufficient that we take the quoted text
without verifying that the next character is the field separator. (Of
course it would be better to make sure field separator follows, as then
quotation marks could be used in the free-form texts.)
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch only implements the feature, indentation fix is to follow.
This ensures that the actual change can be more easily reviewed.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We need to have empty field printed for every value on the CSV export.
Hopefully this is enough.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If the cylinder size seems to be in the form of ALxx, LPxx, or HPxx use
that as cylinder description.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This will read duration from CSV in minutes if the dive would be less
than 10 minutes when treating the duration as seconds.
In practice, this means that free-divers cannot import dive duration
properly from CSV, but this should be sensible for scuba divers.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds support for importing multi-line notes field on CSV import.
Naturally the notes filed must be quoted with " in this case.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch uses pre-defined working pressures on cylinders to roughly
calculate the size in liters. Imperial selection is ignored here as we
can use the prefix to detect if the value seems like imperial unit (and
the type of cylinder varies based on location, not divers preference in
unit).
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If specific value is not available, we need to have an empty value
instead.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Try to grab pressure information from first DC if it is not manually
entered.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We need to limit the DCs from which we grab the depths. Otherwise, we
end up with too many depth values.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If temperature is recorded by a DC it must be taken from under the
divecomputer tag. However, this will prefer the manually written value
if such exists.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is intended to export all the details that someone might copy from a
paper logbook. We need a matching import template to make this simple.
This hasn't been well tested, I'm sure it will break when elements and
attributes are missing.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds support for importing cylinder information from manually kept
dive logs. However, this cannot be used before GUI counterpart is added.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds support for importing temperatures from manually kept dive logs.
However, this cannot be used before GUI counterpart is added.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The existence of location information was tested incorrectly resulting
in erroneously adding these fields if they were not present.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Having the mix name like EANX34 as cylinder description was apparently
confusing, so switching to 'unknown' instead.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds support for importing cylinder information from at least Xdeep
and Diving Log v 5.0.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
UDDF only supports a specific set of alarms. Some events also don't map
to alarms but map to other types of elements in UDDF.
This patch adds a map of the accepted types. Where a map doesn't exist
the type will not be mapped to an alarm, the option then remains to
map it to another kind of element, in the same way that happened with
headings and gas switches.
This removes the need for the specific exclusion of heading and
gas switch, as they are now simply not included in the map.
Signed-off-by: Martin Long <martin@longhome.co.uk>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Using node() along with the node-set seems to grab the weights properly
for me.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Seems that our UDDF export is adding time after the event name. Thus we
need to add reading the following time as well.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Adjust to UDDF 3.2 specification and use proper tag name for air
temperature.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>