... and reset deco information in profile ceiling computation.
The planner test then needs to know about the struct holding the deco
state.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Calculating dive.when + dive.duration doesn't always give the correct
endtime of a dive especially when a dive has surface interval(s) in
the middle.
Using the helper function dive_endtime() fixes this issue.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
When we merge dives, the sample_start and sample_end pressures are only
used in-memory for displaying data to the user. However, we should
update them as well as this will show the user the correct data in the
equipment/cylinder and i.e. SAC calculation.
Fixes#577
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
9m/min (or 10m/min) is the ascent rate assumed by Buhlmann and navy tables,
and the default of most other planning software and dive computers.
Setting the default to 9m/min allows the default behaviour to be consistent
with "expected" behaviour, but does not prevent the user from changing the
preference. There is disagreement between some users whether the final ascent
ascent duration should be considered when determining the length of the final
stop. This change does not alter that at all, but at 9m/min, the difference
is <1min.
See #592
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Most writes to a connected DC are small, typically some
command bytes to get DC in download mode, or to set
some parameter. All this just worked over BLE,
however, sending a full firmware update (on an
OSTC device) failed, as the underlying BLE interface
can only handle small 20 byte BLE packets at once.
So, send max ble->packet_size chuncks at once.
Tested for the following cases (linux desktop with
OSTC3 over BLE):
1) normal download of dive data.
2) read and write settings from configure UI
3) update firmware (from 2.15 to 2.15)
And to my surprise, no flow control credit administration
is required here.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
Stupidly, commit 731d9dc9bd ("DC download: tell user when no new dives
were found") was missing the conditional when to show that messages.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This option should have never been there. This is not how
gradient factors are supposed to work. It would only trick
users to use the wrong value..
Signed-off-by: Robert C. Helling <helling@atdotde.de>
While this interface is deprecated, too much in our existing code depends
on being able to create the QLowEnergyController with just the address.
Additionally, createCentral() is new in Qt 5.7 and therefor this broke
builds on Linux distros that are still on 5.6.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The ordering on Mac appears to be random, but after looking through the
various successful logs of BLE downloads, it seems we always wrote to the
ClientCharacteristicConfiguration descriptor. So try to find that one first,
and only grab the first descriptor in the list if we didn't find a
ClientCharacteristicConfiguration descriptor.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Right now this will only work if you scan for your BLE dive computer every
time. Ideally we should simply initiate a scan and look for that address if
it's not found in the hash.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Dive IDs are unique but same dive number can appear multiple times within
the same database. This can happen for example when user changes the
"next log number" from his computer.
Signed-off-by: Seppo Takalo <seppo.takalo@iki.fi>
The provided strod_flags(str, 0, 0) should work as a drop in replacement
for atof() but does not care about locales which may cause atof() to fail.
strtod_flags() would allow checking of conversion result, but I did not
change the existing logic. This was just regexp search&replace change
to get rid of atof(). I use flags 0 to get more relaxed conversion.
Fixes#574
Signed-off-by: Seppo Takalo <seppo.takalo@iki.fi>
We only cleared the first sensor data when we created new synthetic plot
info entries, because we only used to have one (well, we had the o2
data, but apparently nobody ever noticed that it didn't get properly
interpolated, probably because people who have CCR dives with o2
pressures are few, and the pressure drops are gradual anyway).
Clear all the pressure data, so that the interpolation code doesn't
think we have some existing real sensor data for the plot info entries
in between proper sample entries.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The XML saving code got the multi-sensor case completely wrong, because
it still had one place where it would always save the first pressure,
rather than the pressure from the right sensor.
This was hidden by the fact that old data would be saved using the
legacy model that only ever used the first sensor slot. Only if you
actually had multiple sensor slots used would the bug trigger.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Consider cylinder used also if the first and last sample pressure differ
enough
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We used to only show the first pressure we had, from back when we only
supported a single sensor.
Reported-by: Stefan Fuchs <sfuchs@gmx.de>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Re-do the logic to use add_gas_switch_event() instead of creating event
manually.
Fix the SQL query to find the proper dive id from dive log number.
Signed-off-by: Seppo Takalo <seppo.takalo@iki.fi>
As these are probably manually entered dives with incomplete data, it is
better not to merge them.
See #561
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Setting break is required to wake up Cochran DCs (it doesn't make
sense to me, but it's needed).
Signed-off-by: John Van Ostrand <john@vanostrand.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The USB reset flushes both buffers, but it also solves a problem
waking up a Cochran DCs.
Signed-off-by: John Van Ostrand <john@vanostrand.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Back off was exponential starting at 10ms, which for high baud
rate and no flow-control connections might cause buffer overrun.
This was causing problems when reading Cochran DCs, the hearbeat
byte was being missed.
Signed-off-by: John Van Ostrand <john@vanostrand.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Having two different enums around with more or less the same
definition has lead to unclear code. After removing two not needed
states on the mobile end, the remaining step to one enum for the
credential state becomes almost is simple rename operation.
Unfortunately, I do not know a way to embed a plain C enum
from pref.h into the QMLManager object. So after this, there
are still 2 enums around, but now identical.
This commit is not changing any functionality.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
Prevent button press events from showing on the profile
graph when we import divesoft DLF files.
Reported-by: Marc Arndt
Signed-off-by: Marc Arndt <marc@marcarndt.com>
Print out partial derivatives of stop times with respect to
variation of depth and duratin of last manual segment.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
This allows to go to much smaller granularity without severe
performance penalty. It should also increase performance for
long decompression times.
Currently this leads to missing cached tissue factors, the caching
has to be adopted to this.
Also, for the time being this breaks the bottom gas breaks feature.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
...rather than use a global variable and a macro.
This should be a no-op in preparation to allow planning
several versions of a dive.
Signed-off-by: Robert C. Helling <helling@atdotde.de>