Nothing really special here. Just a split of the only p02 max threshold into
a min threshold and max threshold, and the adaptation of the UI. Change of
translatable strings included.
ref: https://github.com/Subsurface-divelog/subsurface/issues/259
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
For CCR dives we want to display the setpoint and pO2 information,
due to the limited screensize we have to remove the temperature graph or
the view will be to cluttered.
Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
Wfloat-conversion enabled for C++ part of the code
Fix warnings raised by the flag using lrint
Original issue reported on the mailing list:
The ascent/descent rates are sometimes not what is expected.
E.g. setting the ascent rate to 10m/min results in an actual
ascent rate of 9m/min.
This is due to truncating the ascent rate preference,
then effectively rounding up the time to reach each stop to 2s intervals.
The result being that setting the ascent rate to 10m/min
results in 20s to ascend 3m (9m/min), when it should be exactly 18s.
Reported-by: John Smith <noseygit@hotmail.com>
Reported-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
... for consistency, while we are at it.
There are still some internal depth variables which are ints
somebody might take a go at those.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Using gcc option "-Wfloat-conversion" is useful to catch
potential conversion errors (where lrint should be used).
rint returns double and still raises the same warning,
this is why this change updates all rint calls to lrint.
In few places, where input type is a float, corresponding
lrinf is used.
Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
"SP change" info format in info box: Added/changed formating and add "bar" unit.
"waypoint above ceiling" event in info box: Added formating, depth conversation to ft/m and depth unit.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
Enable translation for a few additional internal dive events.
Ensure that all event names in datatrak.c are collected for translation.
Ensure that for gaschange in profile info box the "cyl." string is also translated.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
Add the tankbar to the profile and change the relative positions of the depth
and temperature curves to minimize overlap.
Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
It's not too clever to give 0 a special meaning (as here:
use same gas as for previous leg) when 0 is a legitimate
value.
This should solve Willem's gas disappearance problem when
reediting a dive in the planner.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
When moving the last handle of a dive (in the planner, in dive add, or
when editing a dive), we rescaled the time axis whenever our idea of the
maximum duration that we should show changed. That lead to the odd
situation that you couldn't get to certain dive durations with the
visual editor (e.g. 64 minutes) because just as you approach that time
the scale changes and the dive duration jumps past the desired value.
Fixes issue #174
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When painting the tankbar the function triggers on change in cylinder index,
as a result the new gascolour are changed at the next sample time point.
On a divecomputer with a reasonable fast sample rate the 2-3s offset are hardly
noticable, especially on a longer dive.
For divecomputers with slow sample rate the 10-30s offset are clearly visible.
This is fixed by start painting the new gascolour at the time point of the switch event rather than the time point of the next sample.
Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
...by making the pen start at its first position rather
than first position minus half width.
Sorry for my first attempt to solve this in a totally
differen (read: wrong) way.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
We have two prefernces determining the deco_mode (BUEHLMANN vs VPMB
vs RECREATIONAL): One for the planner (deco_mode) and one for
displaying dives (display_deco_mode). The former is set in the planner
settings while the latter is set in the preferences.
This patch clears up a confusion which of the two to use by introducing
a helper function that selects the correct variable.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
We had (in the wrong place, imo) a new feature that
should differentiate the different deco_modes, you could
plan your dive in buelhman and see it in vpm-b, for instance
but both of them accessed the same pref.
Signed-off-by: Tomaz Canabrava <tcanabrava@kde.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Remove a few uneeded lines and add more loading code for
the preferences.
Signed-off-by: Tomaz Canabrava <tcanabrava@kde.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Stretch out the yellow zone of the HSV scale, because the yellow band of the
true scale appears narrow.
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Color "undersaturated" values relative to inert gas pressure of gas being
breathed, rather than relative to inert gas pressure of air.
Also change slightly the point at which bright green (hue = 120 deg) from 10%
of M value to 0% of M value (=ambient pressure).
Other than the slight shift in lower bound of the green-red scale, this does
not affect the colors of the tissues with inert gas pressure greater than
ambient pressure, which are relative to the Buhlmann M value.
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
By drawing oversize dots for each data point, dots were overlapping such that
the change in tissue presssure wasn't displayed at the right time - typically
out by 1-2 minutes, depending on dive duration.
Drawing a line between discrete points, the data points don't overlap and
change in tissue pressure is displayed at the right time.
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
...otherwise we show garbage before the mouse enters the
profile for the first time.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Separate the VPM-B conservatism preference into diveplan.vpmb_conservatism for
planning dives and prefs.vpmb_conservatism for profile ceiling display of
saved dives.
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I separated out the color scaling and slightly simplified the expressions.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Setting the pen to non-cosmetic means the painted width scales when zoomed
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Make the heat map use a colour scale similar to that by Kevin Watt, as used in
Simon Mitchell's presentation, Decompression Controversies
https://www.youtube.com/watch?v=UY61E49lyos&t=2090&authuser=0
Undersaturated: cyan -> blue ->purple -> black
Supersaturated up to M value: black -> yellow -> red
Exceeding M value: red -> white
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This replaces the tissue percentage graph that probably nobody ever
understood with a heat map like the one used in the discussion
of bubble model deco. The information shown is the same but the
saturation is now in the color while the tissue determines the y
position.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This matches the strings for a couple of generic events from
libdivecomputer that should obviously info or violation events, and
matches quite a few more from the Uemis downloader (as those are much more
specific).
Everything else is still shown as a yellow warning triangle.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
So far this is only supported in the Suunto EON Steel backend, but we
should try to add this to others where we have such a distinction (and
maybe assign different values to the predefined libdivecomputer events).
This also adds three new icons for info, warning, and violation. The
warning icon we had already, but I drew a new one from scratch to have it
match the violation icon.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This becomes obvious with the new severity bits introduced in the Suunto
EON Steel parser.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Determining the correct cylinder index from a known gas mix can be
complicated, but it is trivial to look up the gasmix from the cylinder_t
structure.
It makes sense to remember which cylinder is being used. This simplifies
handling changing a cylinder's gas mix, either directly by the user, or
indirectly in the planner. It also permits tracking of multiple cylinders of
the same mix, e.g. independent twins / sidemount.
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
That's just annoying and pointless. So we arbitrarily say that surface
events within the first and last 30s of the dive are suppressed.
But we now do show them in the middle, in case the sampling rate is too
low, and the profile itself doesn't show that we got to the surface.
These heuristics still needs tweaking - if the profile already shows
that we're at the surface, then we should probably suppress the event
triangle.
But in the meantime this at least gets rid of the truly pointless cases.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Make them use indices into the plot-info, fix calculation of average
depth, and fix and add comments.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>