This creates a destructor for ProfileWidget2 that deletetes its new'ed
objects on exit.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Since replotting is expensive and it is triggered while scrolling
through the list of cylinders, better not do it for improved
user experience and replot only after the combo box loses
focus.
I hope this...
Fixes#768
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Depending on the options shown, the latest change appears to have moved
the temperature graph a bit too low. This seems to work better in my
experiments.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
A profiler session in the planner shows that for deep long dives
a significant amount of CPU time is spent in populate_pressure_information()
which interpolates the cylinder pressure graphs.
This patch introduces a "fast" flag for the replot of the profile
which is active while the mouse button is still pressed and that
suppresses this calculation.
In the future, this flag could be used for other responsiveness tunings
of the plot.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch adds a context menu entry to add a setpoint change
event. In particular, this can be used to turn a logged dive into
a CCR dive.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
For each polygon that we paint we have to step through the
plot_info from the start again.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If not cylinder with type DILUENT or OXYGEN is defined, this function
returns -1 which should not be used as an index to an array. This
patch adds code to check for this return value and exit gracefully.
On line I marked with a comment. Someone more knowledgeable of that part of
code than me should double check that return is here what we want.
[Dirk Hohndel: fixed small oversight...]
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This code sets up the UI that will allow the user to adjust tank pressures
at a gaschange event. The actual changing of the pressure is not
implemented, yet, so this is disabled until someone finds time to do so.
The scenario is this: a tec diver or sidemount diver without pressure
sensors on at least one of their tanks still wants to reasonably
accurately track gas consumption during a dive. The diver takes notes of
the pressures at every tank switch (I find that odd, but apparently some
cave divers indeed do that as they switch back and forth between different
gases) and then wants to adjust the pressures in Subsurface to match those
written down.
One difficulty here is that the first and last pressure of a tank with no
sensor data is still considered "sensor pressure" - this is basically an
implementation detail in the code that is used to do the pressure
interpolation to have constant-SAC pressure plots for tanks without
sensors. So when we check if there is indeed no pressure data available at
the gas change, we can't just work with the interpolated pressure - if
this is the first (or last) time the tank was used, that pressure may be
marked as sensor pressure.
What's missing is the UI to enter the desired new pressure plus the black
magic that actually inserts this into the dive in a way that doesn't break
the assumptions in the rest of the code. I'm running out of time to do
that but wanted to preserve this code so someone can continue this later.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We had the variable. As a pointer. Which we used memset to clear. Ouch -
that smells like some bad cut and paste.
With this change the object keeps the corresponding plotInfo around (just
like some others do) and can use it later. I suspect this code could use
some larger cleanup, but it's a bit too late for this in the development
cycle, I guess. I'm sure I'll regret this in the future...
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
In the context menu of the profile it makes no sense to offer the ability
to switch gases unless there is a gas to switch to.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
RulerNodeItem2::recalculate() does something which is
apparently not a good idea in combination with
RulerNodeItem2::mouseMoveEvent().
Each time the mouse moves, setPos() is called. Then in
recalculate() the x() value is checked and if less than 0
it's changed to x = 0 (setPos(0, y());).
This last call (setPos(0, y());)
however does not work and the value remains less than zero
leaving one of the ruler points outside of the graph.
To solve the issue we add a silly explicit check if x() < 0
before calling setPos() in RulerNodeItem2::mouseMoveEvent().
The 'x() > timeAxis->posAtValue(data->sec)' strangely works
on the other hand.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Also fixes a bug in the diluent pressure interpolation
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
as we load dives and dives, new DiveEvents will be created
but the transparent pixmap never deleted, also this makes
the transparent pixmap only for the correct event, not for
all of them.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Some dive computers appear to have heading data in every sample. In order
to avoid a completely cluttered dive profile we no longer show a flag for
every heading event but instead show a basically transparent pixmap (which
is invisible to the user) that allows us to report the heading information
in the tooltip but leaves the profile uncluttered.
Fixes#586
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Since we only store things in the preferences if they are different from
the default, the existing code that simply compared with the settings
value didn't work when people used the defaults.
We now compare to the actual preference at runtime which should address
that.
Fixes#731
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Yikes this was stupid. We mixed changing the displayed_dive and the
current_dive. So we'd pass in the displayed_dive and a pointer to the
dive_computer structure of the current dc in the current dive. Oops.
This makes much more sense. And:
Fixes#738
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When entering a gas switch manually, explicitly show the different tanks
that are available and correctly switch between different tanks with the
same gas.
See #702
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Instead of the 30 second heuristic we only assume that this is an explicit
first gas if the event coincides the first sample.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This isn't Cobalt specific, this is specific to dive computers that
indicate the first tank that's in use with a gaschange event that
coincides with the first sample.
We need to make sure that we suppress showing that gas change event
(regardless which cylinder it goes to) and instead set the correct
cylinder index from the very start of the dive.
This works with the test data I have and doesn't seem to break thing with
any of the files that I tried... but I'm worried that this is not the
right way to do things.
Fixes#742
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When dropping to the bottom in plan (and add) mode, the gas label was
placed along the diagonal line from (0,0) to the second dive data point
(i.e. the one at the end of the "at deptch" segment). That looks terrible,
the label needs to be along the segment that we are spending at the
bottom.
This patch fixes that problem.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The pre-existing tissue load going into a dive can change if the start
time of a dive changes. Therefore we need to recalculate the ceiling when
editing start time (or date) of a dive.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Instead of hard-coding the icon sizes and spacing, compute them from the
font sizes, that Qt auto-computes from the displya DPI.
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Decode the gasmix data into a sane format when creating the event, and
add the (currently unused) ability to specify a gas change to a
particular cylinder rather than (or in addition to) the gasmix.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When multiple graphs are displayed at the same time they end up being printed on top of each other.
Scale the lowest graph to accommodate the tankbar.
Add an intermediate scaling step to the depth axis when pp graphs or the tissue graph are visible.
Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds a graphical representation of tissue loadings at the current moment during the dive
to the tooltip box. The layout is inspired by the Sherwater Petrel.Add tissue saturation plot to tooltip
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds a toolbox icon to turn on a tissue plot inspired by the bar
graph of the Sherwater Petrel,
It shows the inert gas partial pressures for individual compartments. If
they are below the ambient pressure (grey line) they are shown in units of
the ambient pressure, if they are above, the excess is shown as a
percentage of the allowed overpressure for plain Buehlmann. So it has the
same units as a gradient factor. Thus also the a gradient factor line (for
the current depth) is shown.
The different tissues get different colors, greener for the faster ones and bluer
for the slower ones.
Positioning and on/off icon action still need some tender loving care.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch introduces a new structure holding partial pressures (doubles in bar) for
all three gases and a helper function to compute them from gasmix (which holds fractions)
and ambient pressure. Currentlty this works for OC and CCR, to be extended later to PSCR.
Currently the dive_comp_type argument is unused.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Using QToolBar I was able to remove much of the dead code
from the mainwindow.ui xml file by transforming the QToolButtons
into actions and loading them dynamically in the .cpp code.
I couldn't use the designer for this ( as I wanted ) because
Qt has no notion of ToolBars outside of the areas where the
MainWindow should have one, and we use it in a very different
area.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Basically we could end up in a situation where the plotInfo is no longer
valid, yet the model changes and triggers a redraw before the new data is
passed into the TankBar.
Instead of chasing that race condition it seemed much easier to just copy
the plot_data entries and the gas information in the dive.
Fixes#716
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This worked flawlessly on Mac and Linux, but on Windows I needed to add
the explicit setVisible here - not quite sure why.
Fixes#710
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Turns out that the fix in commit f7119bdccf ("Planner: make sure no old
handles are around when entering Add/Plan") was incorrect. We ONLY want to
remove the existing handlers when we re-plan a dive, NOT when we call add
or plan.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
In some cases we don't appear to remove all of the old handles from the
scene and end up showing a handle from a previous instance of the planner
in the upper right corner of the profile.
This patch makes sure that we remove any stray handles that might still be
around before entereing plan or add mode.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
In some circumstances Qt will draw a really thick border around
rectangles. This explicitly makes the border of the tank bar thin.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Which actually makes the code much clearer as now the object is at the
correct spot on the canvas and the positions inside are relative to that.
No more magic gradiants starting at "92"
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>