Use the new and fancy cylinder idx to record which cylinder we change to
on the DLF import.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
These event types and names where found by sending different data to the
wetnotes.com web page.
I couldn't find where the setpoint settings where stored for the
SP-events, but when looking at the web page, it was clearly stating that
it saw a setpoint of 0.0 bar somewhere in there.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This event type is found in the DLF file Robert got sent. The wetnotes
application can't display files containing this event type.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
There are more event types than 1, so parse that as a unsigned char and
not as a bool.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
After some reverse-engineering i managed to figure out a couple of
values stored in the dive header.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This parses the dive profile from Divesoft Freedom log file. Only the
depth profile is currently supported. There is also something wrong as
the log file cannot be given as parameter but must be opened or imported
once Subsurface is running. Note that so far no metadata is parsed.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This implements importing of dive profile and temperature graph along
with some meta data from a Cobalt Divelog database.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We are quite inconsistent when it comes to reporting back errors.
One case where this caused somewhat unexpected behavior was when the
user would try to open a .csv file by passing it as command line
argument. The file was silently ignored, but treated as if it had been
opened successfully.
Now we issue a somewhat reasonable error message.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The implementation of import for DM5 removed the profileBlob from SQL
query, thus breaking the backward compatibility on import of old dives.
Need to have bot profile and sample blobs within the query...
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
"Converted" DM4 logs are not actually converted, only the database
structure is updated. According to Rainer we should be able to read the
dive profile from the old format in this case.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If DM4 log file is converted to DM5, the sampleBlob is empty.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Change the meaning that _the_ cylinder (as we treat it in OC dives) is the
diluent cylinder (rather than the O2 cylinder). This eliminates special
cases. Now, for CCR, we have to handle the O2 cylinder in addition
(rather than the diluent in addition).
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Oddly we already had code to load this from XML, but nothing else.
This makes the load from XML work like the rest of our code and adds the
save to XML plus the load and save for the git format.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This implements import from Suunto DM5 database, but there is something
wrong with some of the sample dives in the database I received as
sample. It seems that we should detect missing/bogus data and treat it
properly as divelogs.de does with the same dives. Anyway, when we have
proper data, this import appears to produce sensible results.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If the element we are parsing is of type XML_CDATA_SECTION_NODE, we have
to check the node's name from the parent.
Fixes#718
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch adds support for importing the logs from a Poseidon MK6
rebreather. This DC produces logs that contain of a .txt file that has
all the meta data and a .csv file that contains the sample readings. The
CSV file is different from the others in that it has a line per each
sample reading at given time. Thus we have to merge all the lines from
one point in time into one sample reading of ours.
[Dirk Hohndel: addressed some compiler warnings]
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The latest CCR patches had rendered the planner not usable for CCR dives.
This patch corrects this (and reenables the CCR set point column for
segments). The problem was that a new member setpoint of struct divepoint
had been introduced, but there was already po2 which had the same meaning.
This patch merges the two and renames them setpoint to prevent future
confusion.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Decode the gasmix data into a sane format when creating the event, and
add the (currently unused) ability to specify a gas change to a
particular cylinder rather than (or in addition to) the gasmix.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch allows the importing of oxygen sensor and setpoint data from
Poseidon CCR dive logs.
1) Change parse-xml.c to read up to three oxygen sensor values from xml.
and to store the information in sample structures
2) Change parse-xml.c to read o2 setpoint values fro xml and to store
it in sample structures
3) Change dive.c to delete all sensor and setpoint values where
subsequent samples have sensor/setpoint values that are the same.
4) Change profile.c to store the sensor/setpoint values from the samples
into plotinfo.
5) Change the sample Poseidon xml log in the dives directory to ensure
the correct order and hierarchy of the dive and divecomputer nodes.
[Dirk Hohndel: minor cleanup, removed debug code, whitespace]
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch implements the cylinder pressure calculations for diluent
gas in CCR dive computers. This is the third patch for achieving this.
The following were performed:
1) Add two lines to try_to_fill_sample() in parse-xml so that
diluent cylinder pressures are stored from XML dive log file
into structures of sample.
2) Add one line to populate_plot_entries() in profile.c so that
the diluent cylinder pressures are copied from structures of
sample to structures of plot_info.
3) add three constant #defines in profile.h
4) change populate_pressure_information() in gaspressures.c in
order to take into account pressure calculations for the
diluent cylinder, calling subordinate functions in the
appropriate way.
5) change create_plot_info_new() in profile.c in order to initiate
the pressure calculations for the diluent cylinder.
6) Implement two debugging functions (one in profile.c, another
in gaspressures.c). These debugging functions are activated
by means of #defines.
Two function calls dealing with oxygen pressure are currently commented
out. They will be activated in the following patch that attends to CCR
oxygen partial pressure calculation.
[Dirk Hohndel: rather massive whitespace cleanup]
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Sometimes the planner can produce negative pressures (i.e. when the
cylinders are not properly configured) or when the usser ignored
gas management (for whatever reason). When such a dive gets saved and
reread we should not display a further "Strange pressure reading"
warning on the command line.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Select proper SAMPLE_EVENT_GASCHANGE "version" based on helium content
on the mix.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Subsurface has saved gas change events without type attribute at some
point. Thus we need to add the type when reading in log files, if it is
missing. (Gas change logic relies on the type field nowadays.)
Fixes#617Fixes#600
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Since earlier have we had support for our own calculated TTS. This adds
support for holding TTS values reported by a dive computer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Signed vs unsigned comparisons are such a pain. Since we want offsets to
be +/- 30 minutes around the dive we need to allow negative offsets - but
duration_t was defined as uint32_t.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Lets just use pO₂ instead of PO2, ppO2, ppO₂, PO₂.
They all mean the same, but it's better to be
consistent
Signed-off-by: Henrik Brautaset Aronsen <subsurface@henrik.synth.no>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>